IBM System x3650 Baseboard Management Controller (BMC) Update Diskette Version 1.27 (Build ID GGBT41AUS) System Machine Type 7979. CONTENTS ________ 1.0 Overview 2.0 Installation and Setup Instructions 3.0 Configuration Information 4.0 Unattended Mode 5.0 Web Sites and support phone Number 6.0 Trademarks and Notices 7.0 Disclaimer 1.0 Overview ________________________ This diskette will update the Baseboard Management Controller (BMC) firmware only. It will not affect any device drivers. 1.1 To use this diskette, perform the following steps: a). Make sure BIOS version 1.04, or later, is installed. b). Insert this diskette into the diskette drive and restart the system. If your system does not boot from the diskette, use POST/BIOS setup to configure the diskette drive as a boot device. Please refer to the Server Library that was included with your system for additional information. c). Once your system boots, a ramdrive will be created, the appropriate files will be copied to this ramdrive and the BMC update firmware update will execute automatically. d). When you are finished using the utility, remove the diskette from the diskette drive and restart your system. 1.2 Limitations If there is an error in loading the BMC firmware retry loading the software by repeating the instructions in section 1.1. 1.3 Enhancements - none 1.4. Level of Recommendations and Prerequisites for the update: - BIOS version 1.04, or later, must be installed prior to installing this BMC firmware update. - A full tape backup should be completed and verified prior to running this, or any other system upgrade. - RAID configuration should be saved to a diskette: see the "Hardware Maintenance Manual" for more details. 1.5 Dependencies: - If running a BMC update Diskette Version 1.24 build ID GGBT38AUS or later, requires BIOS 1.04 Build ID GGE126AUS. 2.0 Installing and Setup Instructions ______________________________________ To install the firmware on this diskette, perform the following steps: 2.1 Make sure BIOS version 1.04, or later, is installed. 2.2 Make sure your system is powered down. 2.3 Insert the diskette in the diskette drive. 2.4 Power on your system to boot from diskette drive. If your system does not boot from the diskette, use POST/BIOS setup utility to configure the diskette drive as a boot device. 2.5 Once your system boots, a ramdrive will be created, the appropriate files will be copied to this ramdrive and the BMC update firmware update will execute automatically. 2.6 When the update completes, remove the diskette from the drive and restart the system. 2.7 You may clear the BMC's SEL. 3.0 Configuration Information ______________________________________ There is no configuration information necessary. 4.0 Unattended Mode _______________________ The following method of unattended update can be used. Also, check the UpdateXpress CD for availability of unattended installs of this firmware. (The UpdateXpress CD is downloadable from http://www.ibm.com) 4.1 Steps for unattended mode - Download the first BMC update floppy image - Make the floppy - In the autoexec.bat file edit the line that reads: call update.bat so that it is: call update.bat -f 5.0 WEB Sites and Support Phone Number __________________________________________ 5.1 IBM Support Web Site: http://www.pc.ibm.com/support 5.2 IBM System x Web Site: http://www.ibm.com/systems/x/ 6.0. TradeMarks and Notices ______________________________ 6.1 The following terms are trademarks of the IBM Corporation in the United States, or other countries or both: * IBM * Netfinity * Netfinity Manager * Advanced System Management Other company, product, and service names may be trademarks or service marks of others. 7.0. Disclaimer __________________ 7.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 7.2 Note to Government users: Note to U.S. Government users-- Documentation related to restricted rights-- Use, duplication and disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation. (C) Copyright International Business Machines Corporation 2005, 2006, 2007. All rights reserved.