**** START OF SPECIFICATIONS ***************************************** 00010000 * * 00020000 **** MODULE NAME = APSGMSGU * 00030000 * * 00040000 * COMP(APS) PROD(PSF) : RELEASE 2.2.0 * 00050000 * * 00060000 **** DESCRIPTIVE NAME = PSF/MVS MESSAGES AND CODES UPDATES * 00070000 * * 00080000 **** STATUS = VERSION 2, RELEASE 2, LEVEL 0 * 00090000 * * 00100000 **** FUNCTION = * 00110000 * * 00120000 * THIS MODULE CONTAINS ALL OF THE UPDATES TO THE PSF/MVS * 00130000 * MESSAGES AND CODES SINCE THE LAST PUBLISHED VERSION OF * 00140000 * THE MANUAL. * 00150000 * * 00160000 * THE UPDATES ARE PUT IN THE SAME FORMAT AS THEY WERE BEING * 00170000 * PUT IN THE DOC ++HOLDS. * 00180000 * * 00190000 * EACH TIME A NEW APAR HAS UPDATES THE CHANGE ACTIVITY WILL * 00200000 * BE UPDATED AND A NEW SECTION WILL BE ADDED TO THE END OF * 00210000 * THIS MODULE PRECEDED BY A LINE THAT DENOTES THE APAR NUMBER. * 00220000 * * 00230000 * DO NOT GO PAST COLUMN 64 WITH YOUR DOC CHANGES. THE END OF * 00240000 * THE DASHED LINES WITH YOUR APAR NUMBER IN THE TEXT INDICATE * 00250000 * COLUMN 64. * 00260000 * * 00270000 **** RESTRICTIONS * 00280000 * * 00290000 * DO NOT EDIT OR UPDATE THIS FILE ON SAMPLIB AS THE * 00300000 * NEXT APAR THAT CHANGES THIS MODULE WILL DO A TOTAL REPLACE * 00310000 * OF IT THUS OVERLAYING YOUR CHANGES. IF YOU WISH TO MAKE * 00320000 * CHANGES TO THIS MODULE THEN DO IT IN YOUR OWN COPY OF THIS * 00330000 * MODULE. * 00340000 * * 00350000 * *** CHANGE ACTIVITY = * 00360000 * $00=LAPS0006, HPRF220, 970130, BDKURLD: INITIAL VERSION * 00370000 * $01=OW24771 , HPRF220, 970131, BDKURLD: Set Media Size support * 00380000 * $02=OW22539 , HPRF220, 970131, BDKURLD: Line merge support * 00390000 * $03=OW24868 , HPRF220, 970207, BDKUELJ: PRTERROR support * 00400000 * $04=OW25116 , HPRF220, 970210, BDKURLD: Invalid OPC response * 00410000 * $05=OW24057 , HPRF220, 970213, BDKUSCM: MODCA IOB Support * 00420000 * $06=OW24371 , HPRF220, 970220, BDKUJAU: APS935I MESSAGE * 00430000 * $07=OW25449 , HPRF220, 970303, BDKUELJ: Detect printer hang * 00440000 * $08=OW19657 , HPRF220, 970416, BDKURLD: Extended color support * 00450000 * $09=OW21530 , HPRF220, 970416, BDKURLD: Setup verification support * 00460000 * & GOCA set process color * 00470000 * $10=OW27610 , HPRF220, 970616, BDKURLD: Support action code '22' * 00480000 * with TCP/IP * 00490000 * $11=OW22894 , HPRF220, 970416, BDKULD: Color Mapping Table * 00500000 * $12=OW27622 , HPRF220, 970903, BDKULMM Multiple Resolution * 00510000 * $13=OW27623 , HPRF220, 971014, BDKUELJ New OUTPUT keywords * 00520000 * $14=OW29526 , HPRF220, 971021, BDKULMM Persistent NACK during I/O * 00530000 * for recovery * 00540000 * $15=OW29646 , HPRF220, 971024, BDKUELJ OVERLAY on PRINTDEV * 00550000 * $16=OW30000 , HPRF220, 971030, BDKULD Remove message APS559I * 00560000 * $17=OW30255 , HPRF220, 971118, BDKUELJ Redo message APS211I * 00570000 * $18=OW29924 , HPRF220, 971112, BDKUSCM Wide paper & CSE support * 00580000 * $19=OW26734 , HPRF220, 971208, BDKURLB One ACK per sheet * 00590000 * $20=OW29990 , HPRF220, 971203, BDKUSCM Page overlay rotation * 00600000 * $21=OW29992, HPRF220, 980225, BDKUMLC: Assign/Unassign support * 00610000 * $22=OW31717, HPRF220, 980310, BDKUELJ: Inhibit Recovery * 00620000 * $23=OW33942, HPRF220, 980714, BDKURLD: DPF & RPM support * 00630000 * $24=OW24360, HPRF220, 980828, BDKULMM: Finisher Support * 00640000 * $25=OW34806, HPRF220, 980909, BDKUSCM: Basic Nup & conditional * 00650000 * ejects * 00660000 * $26=OW35783, HPRF220, 981020, BDKUWLK: Download premature EOF * 00670000 * $27=OW35455, HPRF220, 981111, BDKUEAS: ABEND024/RC8AD but no * 00680000 * APS292I supporting * 00690000 * message. * 00700000 * $28=OW36139, HPRF220, 981109, BDKURLD: Save connect interval * 00710000 * timer abend * 00720000 * $29=OW36155, HPRF220, 981130, BDKULMM: Add support for stapler * 00730000 * X'22' NACKs * 00740000 * $30=0W36506, HPRF220,981124, BDKUEAS: Wrong MM/DM selected * 00750000 * in job with EDT/BDT * 00760000 * $31=0W37992, HPRF220, 990317, BDKURLD: Denote PSF version * 00770000 * $32=0W38417, HPRF220, 990430, BLDCWJ: Rolldown or CCM function * 00780000 * $33=0W39266, HPRF220, 990519, BLDEAS: Hold data set on RSSN0417 * 00780000 * $34=OW40216, HPRF220, 990721, BLDCWJ: ABEND24/323 IN APSLOPEN * * $35=OW39931, HPRF220, 990722, BLDCWJ: Rolldown/inhibit CCM Eldo+ * * $36=OW41705, HPRF220, 991104, BLDCWJ: loop when small page * * length set at printer * * $37=OW42286, HPRF220, 000111, BLDCWJ: APS502I issued * * $38=OW42838, HPRF220, 000131, BDKURLD: Handle session closed * * $39=OW41510, HPRF220, 000320, BDKULMM: Enable inline capture on * * WPM * * $40=OW43469, HPRF220,000321,BDKURLD: Add TCP/IP name to WTO * * messages * * $41=OW44001, HPRF220,000509,BDKURLD: Invalid TCP/IP prefix message * * length * 00790000 * $42=OW45057, HPRF220,000620,BDKURLD: No change, supercede OW43469 * * $43=OW44399, HPRF220,000515,BLDCWJ : Media Fidelity support * * * 00790000 **** END OF SPECIFICATIONS ******************************************* 00800000 00810000 All of the following changes are for Print Services 00820000 Facility/MVS Messages and Codes Version 2, 00830000 Release 2, Modification 0 (S544-3675-03). 00840000 00850000 -----------CHANGES FOR OW24771---------------------------------- 00860000 00870000 1. On page 163 following APS613I, add: 00880000 00890000 APS614I INVALID VALUE SPECIFIED FOR FORMLEN KEYWORD. 00900000 00910000 Explanation: The value given for FORMLEN was not numeric or 00920000 it contained more than two digits before the decimal point 00930000 or more than three digits following the decimal point, 00940000 or it was not followed by 'IN' or 'CM'. 00950000 00960000 System Action: The data set is not printed. 00970000 00980000 User Response: Correct the specification for FORMLEN and 00990000 resubmit the job. 01000000 01010000 System Programmer Response: No response is necessary. 01020000 01030000 Operator Response: No response is necessary. 01040000 01050000 Problem Determination: Items 2, 3. 01060000 01070000 -----------CHANGES FOR OW22539---------------------------------- 01080000 01090000 1. On page 255 change APS958I to read as follows. 01100000 01110000 PSF INSTALLATION EXITS WILL NOT BE INVOKED. 01120000 01130000 2. On page 255 change the "System Action" for APS958I to 01140000 read as follows. 01150000 01160000 System Action: Processing continues without installation 01170000 exits. 01180000 01190000 3. Remove the following sentence from the message text for 01200000 APS970I, APS971I, APS972I, APS973I, APS974I, APS976I, 01210000 APS977I, APS978I, APS979I, and APS980I. 01220000 01230000 The dataset will be held by the system. 01240000 01250000 4. Change the System Action to read as follows for 01260000 APS970I, APS971I, APS972I, APS973I, APS974I, APS976I, 01270000 APS977I, APS978I, and APS979I. 01280000 01290000 System Action: PSF stops processing and printing the 01300000 data set. In deferred printing mode PSF releases 01310000 the data set back to JES and requests that it be held 01320000 by the system. 01330000 01340000 5. On page 257 change the System Programmer Response for 01350000 APS970I to read as follows. 01360000 01370000 System Programmer Response: The installed version 01380000 of APSUX04/APSUX14 requested that 01390000 the 3800 line-mode conversion function be performed 01400000 for this data set. If the conversion function is in fact 01410000 required, PSF cannot determine the correct formatting 01420000 of each page, because no FCB is specified. Either specify 01430000 an installation default FCB, or request that the job be 01440000 printed in JES 3800 compatibility mode or on a 3900 printer 01450000 with the 3800 compatibility mode for 3900 RPQ 8B3997 01460000 installed. 01470000 01480000 If you do not want 3800 line-mode conversion for this 01490000 data set, change APSUX04/APSUX14 to specify no 01500000 conversion. 01510000 01520000 6. On page 257 change the System Programmer Response for 01530000 APS971I to read as follows. 01540000 01550000 System Programmer Response: If the data set should not be 01560000 converted from 3800 line mode to PSF line mode, change 01570000 APSUX04/APSUX14 to request that the is data set not be 01580000 converted. 01590000 01600000 7. On page 259 change the User Response for APS978I to 01610000 read as follows. 01620000 01630000 User Response: Ensure that data sets requiring 3800 01640000 line-mode conversion are routed to a printer other than 01650000 the 3800. Otherwise, print the data set using JES in 01660000 3800-1 compatiblity mode, or route it to a 3900 printer 01670000 with the 3800 Compatibility for 3900 RPQ 8B3997 installed; 01680000 or change APSUX04/APSUX14 so that conversion is never 01690000 requested for print jobs running to a 3800. 01700000 01710000 8. On page 259 change the 2nd sentence under the System 01720000 Programmer Response for APS978I to read as follows. 01730000 01740000 If 3800 line-mode conversion is not desired for the data 01750000 set, modify APSUX04/APSUX14 to request that no conversion 01760000 be done for the data set. 01770000 01780000 9. On page 260 change the "Explanation" for APS980I to read 01790000 as follows. 01800000 01810000 The data set being processed was identified as requiring 01820000 3800 line-mode conversion. However, the OPEN attempt 01830000 on SYS1.IMAGELIB failed 01840000 01850000 10. On page 260 change the "System Action" for APS980I to read 01860000 as follows. 01870000 01880000 PSF stops processing and printing the data set. In deferred 01890000 printing mode PSF will release the current data set back 01900000 to JES and will request that it be held by the system. 01910000 01920000 -----------CHANGES FOR OW24868---------------------------------- 01930000 01940000 1. On page 7, add 01950000 01960000 APS030I PRINT DATA SET DISPOSITION WAS NOT CHANGED AS 01970000 REQUESTED BY PRTERROR BECAUSE reason. 01980000 01990000 Explanation: The output data set was terminated due to an 02000000 error, but the dispostion of the data set was not changed for 02010000 one the following reasons: 02020000 02030000 HONOR PRTERROR IS NOT INITIALIZED. 02040000 The PRINTDEV initialization statement for this printer does 02050000 not specify PRTERROR=HONOR. 02060000 02070000 A PSF EXIT REQUESTED THE DATA SET BE HELD. 02080000 PSF installation exit APSUX06 or APSUX07 specified that the 02090000 data set should be held. 02100000 02110000 MANDATORY PRINT LABELING IS IN EFFECT. 02120000 The RACF (Resource Access Control Facility) class PSFMPL is 02130000 active on the system. 02140000 02150000 System Action: The default disposition for the error is taken 02160000 or, if an exit requested it, the data set is held. 02170000 02180000 User Response: If honor PRTERROR is not initialized, ask your 02190000 system programmer to initialize it. 02200000 02210000 System Programmer Response: If users are to be allowed to set 02220000 the error disposition, add PRTERROR=HONOR on the PSF 02230000 PRINTDEV statement for the printer. 02240000 02250000 Operator Response: No response is necessary. 02260000 02270000 Problem Determination: Items 2, 3, 12, 13. 02280000 02290000 2. For messages APS501I, APS503I, APS504I, APS707I, APS819I, 02300000 APS872I, APS874I, APS970I, APS971I, APS972I, APS973I, 02310000 APS974I, APS976I, APS977I, APS978I, APS979I, APS980I, 02320000 change the text in the System Action from 02330000 ... release the current data set back to JES and request 02340000 that it be held by the system. 02350000 to 02360000 ... release the current data set back to JES and request 02370000 that it be held by the system unless PRTERROR=QUIT was 02380000 specified on the OUTPUT statement. 02390000 02400000 -----------CHANGES FOR OW25116---------------------------------- 02410000 02420000 1. On page 289 add new abend reason code 0242 described as 02430000 follows. 02440000 02450000 0242 02460000 02470000 Explanation: This abend is issued by module 02480000 APSCOPCI-- 02490000 The actual medium presentation space width, actual medium 02500000 presentation space length, Xm extent of the physical 02510000 printable area in L-units, or Ym extent of the physical 02520000 printable area in L-units returned in the XOA Obtain Printer 02530000 Characteristics acknowledge reply was X'0000'. 02540000 02550000 System Action: PSF processing terminates abnormally. 02560000 02570000 System Programmer Response: This PSF abend reason code 02580000 indicates a logic error in the microcode of the printer. 02590000 Consult your hardware service representative. This is 02600000 NOT a PSF logic error. 02610000 02620000 -----------CHANGES FOR OW24057---------------------------------- 02630000 02640000 1. Add the following messages: 02650000 02660000 APS386I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: A 02670000 REQUIRED TRIPLET WITH ID X'4B' WAS MISSING FROM AN IOB 02680000 STRUCTURED FIELD. 02690000 02700000 EXPLANATION: The x or y axis origin for object content or an 02710000 object area size (X'4C') triplet was specified on an IOB but 02720000 no measurement units (X'4B)' triplet was specified. The 02730000 structured field is contained in a print data set or overlay. 02740000 02750000 SYSTEM ACTION: PSF terminates the page or overlay containing 02760000 the structured field in error. PSF attempts to locate the end 02770000 of the current page and resume processing on the next page. If 02780000 the end of the current page cannot be located, PSF stops 02790000 printing the data set. 02800000 02810000 PSF issues a message identifying the position of the structured 02820000 field in the input data stream or resource. PSF issues 02830000 additional messages that identify the processing environment 02840000 when the error was found. 02850000 02860000 USER RESPONSE: If you placed the IOB structured field in the 02870000 print data set or overlay, correct the error and resubmit the 02880000 print request. Refer to Mixed Object Document Content 02890000 Architecture Reference for more information about the structured 02900000 field. If you used a program to place the IOB structured field 02910000 in the print data set or overlay, contact your system 02920000 programmer. 02930000 02940000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 02950000 to place the IOB structured field in the print data set or 02960000 overlay, verify that the input to that program was valid. If it 02970000 was valid, refer to Advanced Function Printing: Diagnosis Guide 02980000 and Print Services Facility/MVS: Diagnosis Guide and Reference 02990000 for assistance in determining the source of the problem. 03000000 03010000 OPERATOR RESPONSE: No response is necessary. 03020000 03030000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 03040000 03050000 03060000 APS387I DATA IN AN INPUT RECORD IS INVALID: PARAMETER IN AN IOB 03070000 STRUCTURED FIELD CONTAINS UNACCEPTABLE DATA. 03080000 03090000 EXPLANATION: One of the parameters in the Include Object (IOB) 03100000 structured field is invalid. The object type specified is not 03110000 supported or is invalid OR the x or y offset of the object area 03120000 or the rotation value are not explicitly specified when the 03130000 reference coordinate system is set to X'00'. The IOB 03140000 structured field is contained in the print data set or an 03150000 overlay. 03160000 03170000 SYSTEM ACTION: PSF terminates the page or overlay containing 03180000 the structured field in error. PSF attempts to locate the end 03190000 of the current page and resume processing on the next page. If 03200000 the end of the current page cannot be located, PSF stops 03210000 printing the data set. 03220000 03230000 PSF issues a message identifying the position of the structured 03240000 field in the input data stream or resource. PSF issues 03250000 additional messages that identify the processing environment 03260000 when the error was found. 03270000 03280000 USER RESPONSE: If you placed the IOB structured field in the 03290000 print data set or overlay, correct the error and resubmit the 03300000 print request. Refer to Mixed Object Document Content 03310000 Architecture Reference for more information about the structured 03320000 field. If you used a program to place the IOB structured field 03330000 in the print data set or overlay, contact your system 03340000 programmer. 03350000 03360000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 03370000 to place the IOB structured field in the print data set or 03380000 overlay, verify that the input to that program was valid. If it 03390000 was valid, refer to Advanced Function Printing: Diagnosis Guide 03400000 and Print Services Facility/MVS: Diagnosis Guide and Reference 03410000 for assistance in determining the source of the problem. 03420000 03430000 OPERATOR RESPONSE: No response is necessary. 03440000 03450000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 03460000 03470000 03480000 APS388I DATA IN A PAGE SEGMENT IS INVALID: structured field 03490000 STRUCTURED FIELD IS NOT ALLOWED IN A PAGE SEGMENT 03500000 INCLUDED WITH AN IOB. 03510000 03520000 EXPLANATION: Only MODCA page segments are allowed to be 03530000 included with an IOB structured field. MODCA page segments 03540000 cannot contain IM1 image or PTOCA data. 03550000 03560000 SYSTEM ACTION: PSF terminates the page or overlay containing 03570000 the structured field in error. PSF attempts to locate the end 03580000 of the current page and resume processing on the next page. If 03590000 the end of the current page cannot be located, PSF stops 03600000 printing the data set. 03610000 03620000 PSF issues a message identifying the position of the structured 03630000 field in the input data stream or resource. PSF issues 03640000 additional messages that identify the processing environment 03650000 when the error was found. 03660000 03670000 USER RESPONSE: If you placed the IOB structured field in the 03680000 print data set or overlay, correct the error and resubmit the 03690000 print request. Refer to Mixed Object Document Content 03700000 Architecture Reference for more information about the structured 03710000 field. If you used a program to place the IOB structured field 03720000 in the print data set or overlay, contact your system 03730000 programmer. 03740000 03750000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 03760000 to place the IOB structured field in the print data set or 03770000 overlay, verify that the input to that program was valid. If it 03780000 was valid, refer to Advanced Function Printing: Diagnosis Guide 03790000 and Print Services Facility/MVS: Diagnosis Guide and Reference 03800000 for assistance in determining the source of the problem. 03810000 03820000 OPERATOR RESPONSE: No response is necessary. 03830000 03840000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 03850000 03860000 2. For messages: APS500I,APS502I,APS532I,APS548I 03870000 Change references to SEGMENT in the list for resource types to: 03880000 03890000 SEGMENT to SEGMENT/OCA 03900000 SECURITY SEGMENT to SECURITY SEGMENT/OCA 03910000 PAGE SEGMENT RESOURCE to PAGE SEGMENT/OCA RESOURCE 03920000 INLINE SEGMENT to INLINE SEGMENT/OCA 03930000 03940000 3. Change the text phrase "PAGE SEGMENT" in messages APS555I, 03950000 APS561I, and APS563I to "PAGE SEGMENT/OCA OBJECT". 03960000 03970000 4. Change the following message's message text & explanation: 03980000 03990000 APS278I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 04000000 OUTPUT OPTION SPECIFIED IN THE structured field name 04010000 IS INVALID OR UNSUPPORTED. 04020000 04030000 EXPLANATION: The structured field in error contained an invalid 04040000 Output Option value or the printer does not support the Output 04050000 Option value. The structured field can be contained in a bar 04060000 code object, graphics object, image object or it was 04070000 specified on an IOB structured field. The bar code object, 04080000 graphics object, image object, or IOB can be contained in an 04090000 overlay, MODCA page, or it can be embedded in line data. 04100000 04110000 5. Add abend: 04120000 04130000 0820 04140000 Explanation: This abend is issued by module APRIOBEX - 04150000 The library type indicated in the library parameter from 04160000 APSRNAME is unrecognizable. 04170000 System Action: PSF processing terminates abnormally. 04180000 System Programmer Response: This PSF abend reason code indicates 04190000 a possible logic error. Contact your service representative 04200000 in the IBM Support Center or use your electronic link with 04210000 IBM service for assistance regarding this error code. 04220000 04230000 -----------CHANGES FOR OW24371---------------------------------- 04240000 04250000 1. On page 250 replace the Explanation for APS934I with: 04260000 04270000 Explanation: 04280000 A network or printer error occurred, causing communication with 04290000 the printer to end. The TCP/IP session with the printer cannot 04300000 be reestablished, for one of the following reasons: 04310000 04320000 -The error condition cannot be retried. 04330000 -The PSF PRINTDEV specified FAILURE=STOP. 04340000 -The retry limit has been reached. 04350000 04360000 The APS934I message is issued from the PSF/MVS ESTAE and does 04370000 not have complete information if the error is a network error 04380000 or printer communication error. In some cases APS935I will 04390000 precede APS934I and has more detailed CAUSE information. If 04400000 the APS935I message is issued, always use APS935I to determine 04410000 the cause. 04420000 04430000 If PSF retried the error, you will have received corresponding 04440000 APS935I messages. 04450000 04460000 TCP/IP ERRNO(errno) indicates the TCP/IP error. 04470000 To interpret the errno, refer to TCP/IP for MVS: 04480000 Application Programming Interface Reference. 04490000 04500000 Common ERRNO's associated with this message are: 04510000 49 - can't reach destination, indicating a bad IP address 04520000 60 - printer may be powered off 04530000 61 - connection was refused. This may happen when the printer is 04540000 in the process of accepting a connection with another partner 04550000 and refuses other connections while completing the current 04560000 request. Another cause is connecting to a valid IP address 04570000 but the target system is not a printer or host that has the 04580000 IBM printer layer code. 04590000 04600000 PRINTER(prtnnnn) specifies the name of the PRINTDEV statement. 04610000 IP ADDRESS(ip-address) specifies the Internet Protocol (IP) 04620000 address of the TCP/IP-attached printer. CAUSE can be any of 04630000 the following: 04640000 04650000 - START SESSION FAILED - PSF failed to establish a session 04660000 with the printer because of either a timeout waiting 04670000 for a reply from the printer or a communication error. 04680000 PSF displays this reason when: 04690000 04700000 o If the printer is attached with an i-data 7913 IPDS Printer 04710000 LAN Attachment, either the printer or the i-data 7913 IPDS 04720000 PRINTER LAN Attachment is not powered on. 04730000 o The printer is not physically attached. 04740000 o The wrong IP address is specified in the PRINTDEV statement. 04750000 o The IP address specified in the PRINTDEV statement is a 04760000 duplicate of another ip address on the network. 04770000 04780000 - PRINTER ASSIGN FAILED - The host request to assign the printer 04790000 failed. The printer can be reached, but it did not accept the 04800000 assignment request 04810000 04820000 - PRINTER ASSIGNED ELSEWHERE - The printer(prtnnnn) at IP 04830000 address(ip-address) is being used by another host application. 04840000 Only one task such as PSF can communicate with the printer at 04850000 any given time. 04860000 04870000 - PRINTER ASSIGN TIMEOUT - The printer did not reply to a host 04880000 request for assignment of an IPDS conversation. 04890000 04900000 - INVALID MESSAGE VERSION - This indicates an 04910000 incompatibility between PSF and the printer. 04920000 If the communication failure occurs with a printer supported 04930000 by PSF, notify your system programmer of this error. 04940000 04950000 - NONACK RETRY - Communication with the printer was terminated, 04960000 but is a RETRY condition. PSF will try to re-establish 04970000 communication with the printer. 04980000 04990000 - NONACK NORETRY - Communication with the printer was 05000000 terminated. 05010000 PSF displays this reason when: 05020000 o The printer has a hardware failure. 05030000 o The connection with the printer is lost. 05040000 o An unknown communication failure. 05050000 05060000 - NONACK COMMERR - PSF lost communication with the printer 05070000 due to either a timeout waiting on a reply 05080000 from the printer or a communication error. PSF displays this 05090000 reason when: 05100000 o The physical connection with the printer is lost. 05110000 05120000 05130000 2. On page 251 replace the Explanation for APS935I with: 05140000 05150000 Explanation: 05160000 Communication with the printer was ended for a condition that 05170000 can be retried. 05180000 PSF has just retried to establish the session. 05190000 05200000 TCP/IP ERRNO(errno) indicates the TCP/IP error. 05210000 To interpret the errno, refer to 05220000 TCP/IP for MVS: Application Programming Interface Reference. 05230000 Common ERRNO's associated with this message are: 05240000 49 - can't reach destination, indicating a bad IP address 05250000 60 - printer may be powered off 05260000 61 - connection was refused. This may happen when the printer 05270000 is in the process of accepting a connection with another 05280000 partner and refuses other connections while completing 05290000 the current request. Another cause is connecting to a 05300000 valid IP address but the target system is not a printer 05310000 or host that has the IBM printer layer code. 05320000 05330000 PRINTER(prtnnnn) specifies the name of the PRINTDEV statement. 05340000 IPADDR(ip-address) specifies the Internet Protocol (IP) address 05350000 of the TCP/IP-attached printer. CONDITION can be any of the 05360000 following: 05370000 05380000 - SOCKET FAILED - PSF was not able to get a socket on MVS 05390000 05400000 - SOCKET CONNECT FAILED - PSF was not able to establish a socket 05410000 connection with the printer. The printer may be powered off. 05420000 05430000 - IOCTL FAILED - The socket connection requires a non-blocking 05440000 socket but the call to make the socket non-blocking failed. 05450000 05460000 - SETSOCKOPT FAILED - The call to set the KEEPALIVE option on 05470000 for the socket connect failed. 05480000 05490000 - START SESSION FAILED - PSF failed to establish a session 05500000 with the printer due to either a timeout waiting 05510000 for a reply from the printer, or a communication error. 05520000 A session is defined as a connection to the IBM printer layer 05530000 code executing in the printer, not a TCP/IP connection to 05540000 the printer. PSF displays this reason when: 05550000 05560000 o If the printer is attached with an i-data 7913 IPDS 05570000 Printer LAN Attachment, either the printer or the i-data 05580000 7913 IPDS Printer LAN Attachment is not powered on. 05590000 o The wrong IP address is specified in the PRINTDEV statement. 05600000 o The target system is not executing the IBM printer layer 05610000 code. 05620000 o The printer is being used by another PSF FSA on the same 05630000 host. 05640000 05650000 - PRINTER ASSIGN FAILED - The host request to assign the printer 05660000 failed. The printer can be reached, but it did not accept the 05670000 assignment request 05680000 05690000 - PRINTER ASSIGNED ELSEWHERE - The printer(prtnnnn) at IP 05700000 address(ip-address) is being used by another host application. 05710000 Only one task such as PSF can communicate with the printer at 05720000 any give time. 05730000 05740000 - PRINTER ASSIGN TIMEOUT - The printer did not reply to a host 05750000 request for assignment of an IPDS conversation. 05760000 05770000 - NONACK RETRY - Communication with the printer was terminated. 05780000 05790000 - NONACK COMMERR - PSF has lost communications with the printer 05800000 due to either a timeout waiting for a reply from the printer 05810000 or a communication error. PSF displays this message when: 05820000 o If the printer was attached but for some reason the 05830000 connection is severed though a hardware or software problem. 05840000 05850000 3. On page 251 for APS935I, replace the System Action with: 05860000 05870000 System action: 05880000 Start of the session has been retried, and PSF waits for the 05890000 activation to complete. If FAILURE=WCONNECT was specified on 05900000 the PRINTDEV statement in the PSF startup procedure, PSF 05910000 attempts to restart the session continuously, issuing the 05920000 APS935I message only when the ERRNO or REASON code changes 05930000 between retries. 05940000 05950000 05960000 4. On page 253 for APS948I, modify the INIT API 05970000 HUNG condition under the System Programmer Response to: 05980000 05990000 o INIT API HUNG - You must cancel the PSF address space, and 06000000 notify your IBM Support Center. 06010000 06020000 06030000 5. On page 253 for APS949I modify the Operator Response to: 06040000 06050000 Verify that the TCP/IP procedure with the tcp_ip name was 06060000 started. If the TCP/IP task has not been started, you must 06070000 cancel the writer procedure; then start the TCP/IP task and 06080000 restart the printer. 06090000 06100000 -----------CHANGES FOR OW25449---------------------------------- 06110000 06120000 1. On page 163 add 06130000 06140000 APS615I RESPTIME OR NORESP KEYWORD SPECIFIED WITHOUT THE OTHER 06150000 ON THE prtnnn PRINTDEV STATEMENT. 06160000 06170000 Explanation: The NORESP keyword defines the action to be taken 06180000 when the time specified by the RESPTIME keyword expires. If one 06190000 of these keywords is specified, both must be given. Only one of 06200000 them was specified. 06210000 06220000 System Action: Startup of the FSA for prtnnn was aborted. 06230000 06240000 User Response: N/A 06250000 06260000 System Programmer Response: Correct the PRINTDEV statement for 06270000 prtnnn. 06280000 06290000 Operator Response: Notify your system programmer that this 06300000 message was received. 06310000 06320000 Problem Determination: 1, 17, 24 06330000 06340000 06350000 2. On page 163 add 06360000 06370000 APS616I THE NORESP KEYWORD ON THE prtnnn PRINTDEV STATEMENT 06380000 CONTAINS AN INVALID ACTION PARAMETER. 06390000 06400000 Explanation: The NORESP keyword was specified on the PRINTDEV 06410000 statement for printer prtnnn with an invalid action type. 06420000 06430000 System Action: Startup of the FSA for prtnnn was aborted. 06440000 06450000 User Response: N/A 06460000 06470000 System Programmer Response: Correct the PRINTDEV statement for 06480000 prtnnn. 06490000 06500000 Operator Response: Notify your system programmer that this 06510000 message was received. 06520000 06530000 Problem Determination: 1, 17, 24 06540000 06550000 06560000 3. On page 163 add 06570000 06580000 APS617I THE FORMAT OF THE NOTIFY OPTION OF THE NORESP KEYWORD IS 06590000 INVALID ON THE prtnnn PRINTDEV STATEMENT. 06600000 06610000 Explanation: NORESP=NOTIFY.... was specified on the PRINTDEV 06620000 statement for printer prtnnn, but the format of the NOTIFY 06630000 option was incorrect. 06640000 06650000 System Action: Startup of the FSA for prtnnn was aborted. 06660000 06670000 User Response: N/A 06680000 06690000 System Programmer Response: Correct the PRINTDEV statement for 06700000 prtnnn. 06710000 06720000 Operator Response: Notify your system programmer that this 06730000 message was received. 06740000 06750000 Problem Determination: 1, 17, 24 06760000 06770000 06780000 4. On page 248 add 06790000 06800000 APS926I NORESP NOTIFY FAILED FOR prtnnn, RETURN CODE = rc. 06810000 06820000 Explanation: NORESP=NOTIFY was specified on the PRINTDEV 06830000 statement for printer prtnnn. When a no response timeout 06840000 occurred for this printer, the notify was attempted but 06850000 failed with the return code indicated. 06860000 06870000 System Action: The NORESP action is changed to NORESP = 06880000 NOTIFY(OPERATOR) and the notify messages were directed to the 06890000 system operator. 06900000 06910000 User Response: N/A 06920000 06930000 System Programmer Response: Correct the PRINTDEV statement for 06940000 prtnnn. 06950000 06960000 Operator Response: Notify your system programmer that this 06970000 message was received. 06980000 06990000 Problem Determination: 1, 17, 24 07000000 07010000 07020000 5. On page 252 add 07030000 07040000 APS940I REQUIRED RESPONSE NOT RECEIVED FROM prtnnn. 07050000 07060000 Explanation: The time specified by the PRINTDEV RESPTIME keyword 07070000 for prtnnn expired before PSF received a response from the 07080000 printer. 07090000 07100000 System Action: The action specified by the NORESP keyword on the 07110000 PRINTDEV statement is taken. 07120000 07130000 User Response: Have the person responsible for the printer check 07140000 the printer to determine why it is not responding to PSF and 07150000 correct the condition. 07160000 07170000 System Programmer Response: Have the person responsible for the 07180000 printer check the printer to determine why it is not responding 07190000 to PSF and correct the condition. 07200000 07210000 Operator Response: Have the person responsible for the printer 07220000 check the printer to determine why it is not responding to PSF 07230000 and correct the condition. 07240000 07250000 Problem Determination: 8, 12, 13, 19 07260000 07270000 6. On page 252 add 07280000 07290000 APS941I MISSING RESPONSE RECEIVED FROM prtnnn. 07300000 07310000 Explanation: This message follows APS940I and indicates that the 07320000 problem is corrected and the printer is now responding to PSF. 07330000 07340000 System Action: None 07350000 07360000 User Response: None 07370000 07380000 System Programmer Response: None 07390000 07400000 Operator Response: None 07410000 07420000 Problem Determination: N/A 07430000 07440000 07450000 7. On page 289, add 07460000 07470000 025A 07480000 07490000 Explanation: This abend is issued by module APSCNORS when the 07500000 RESPTIME timer expires before a response is received from the 07510000 printer if NORESP=TERMINATE was specified on the PRINTDEV 07520000 statement. 07530000 07540000 System Action: This abend is preceeded by message APS940I with 07550000 prtnnn identifying the FSA for which this occurred. The FSA for 07560000 the printer is terminated. 07570000 07580000 Operator/System Programmer Response: Determine why the printer 07590000 is not responding and correct the problem. Then, restart the 07600000 FSA. 07610000 07620000 8. On page 347, add 07630000 07640000 0E99 07650000 07660000 Explanation: This abend is issued by module APSNTERM when a 07670000 FREEMAIN failure occurs. 07680000 07690000 System Action: PSF processing terminates abnormally. 07700000 07710000 System Programmer Response: This PSF abend reason code indicates 07720000 a possible logic error. Contact your service representative in 07730000 the IBM Support Center or use your electronic link with IBM 07740000 service for assistance regarding this error code. 07750000 07760000 -----------CHANGES FOR OW19657---------------------------------- 07770000 07780000 1. On page 173, following the entry for APS703I add: 07790000 07800000 APS704I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 07810000 IMAGE COLOR VALUE SPECIFIED IS INVALID OR UNSUPPORTED. 07820000 07830000 EXPLANATION: The image color value specified is invalid or 07840000 unsupported by this printer. 07850000 The image color value is specified on any of the 07860000 following structured fields: 07870000 07880000 o the IM Image Input Descriptor (IID), 07890000 o the Image Data Descriptor (IDD) for IOCA images 07900000 07910000 The image or image cell may be contained in an overlay, a page 07920000 segment, or MO:DCA data. It may also be imbedded in a data set 07930000 containing line data, using a Begin Image(BIM) structured field. 07940000 07950000 SYSTEM ACTION: If the image is in a page, the printer you were 07960000 using may attempt to print the page in error. The entire page 07970000 may not print. If the page in error contains any positioning 07980000 errors, then print-error markers may be included on the printed 07990000 page. PSF continues processing of the current data set with the 08000000 page following the page in error, unless the printer reported 08010000 another error that required a more severe PSF recovery action. 08020000 08030000 If the image is in a resource, PSF stops processing the data 08040000 set that uses the resource in error. 08050000 08060000 USER RESPONSE: If the color value is unsupported by 08070000 this printer resubmit the print request to a printer 08080000 that does support this color value. 08090000 08100000 If the structured fields are invalid and 08110000 you created the structured fields for the resource or print data 08120000 set containing the image, correct the error in the referenced 08130000 structured field and resubmit the print request. Refer to Mixed 08140000 Object Document Content Architecture Reference for more 08150000 information about the structured field. If the structured field 08160000 has no error, the error may be a PSF or printer logic error. If 08170000 you used a program to create the structured fields for the 08180000 resource or print data set containing the image, contact your 08190000 system programmer. 08200000 08210000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 08220000 to create the structured fields for the print data set or the 08230000 resource with the error, verify that the input to that program 08240000 was valid. If the input was valid, refer to Advanced Function 08250000 Printing: Diagnosis Guide and Print Services Facility/MVS: 08260000 Diagnosis Guide and Reference for assistance in determining the 08270000 source of the problem. If the error involves separator pages or 08280000 the message data set, use the information provided in the User 08290000 response section to correct the error. 08300000 08310000 OPERATOR RESPONSE: If the message appears on the operator's 08320000 console, it indicates that the resource containing the error is 08330000 defined for a separator page or the message data set in the PSF 08340000 startup procedure. Inform your system programmer. 08350000 08360000 PROBLEM DETERMINATION: Items 1, 2, 17, 27. 08370000 08380000 2. On page 199, preceding the entry for APS771I add: 08390000 08400000 APS770I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 08410000 COLOR SPACE VALUE IN A X'4E' TRIPLET OR SET 08420000 EXTENDED COLOR CONTROL SEQUENCE IS INVALID OR 08430000 UNSUPPORTED. 08440000 08450000 EXPLANATION: The color space field in a X'4E' triplet 08460000 or Set Extended Color control sequence contained an invalid or 08470000 unsupported value for this printer. 08480000 08490000 The X'4E' triplet might have occurred on 08500000 the following structured fields: 08510000 08520000 o a Page Descriptor (PGD), 08530000 o an Object Area Descriptor (OBD) 08540000 08550000 The PGD is contained in an Active Environment Group (AEG) for a 08560000 page or an overlay and the OBD is contained in an Object 08570000 Environment Group(OEG) for a graphics, image or bar code object. 08580000 08590000 The Set Extended Color control sequence is located in a 08600000 Presentation Text Data (PTX) structured field. The structured 08610000 field may be contained in MO:DCA data, an overlay, or a page 08620000 segment; or it may be imbedded in a data set containing line 08630000 data. 08640000 08650000 SYSTEM ACTION: The printer you were using may attempt 08660000 to print the page in error. The entire page may not be 08670000 printed. If the page in error contains any positioning errors, 08680000 then print-error markers may be included on the printed page. 08690000 PSF continues processing of the current data set with the page 08700000 following the page in error, unless the printer reported 08710000 another error that required a more severe PSF recovery action. 08720000 08730000 If the object is in a resource, PSF stops processing the data 08740000 set that uses the resource in error. 08750000 08760000 USER RESPONSE: If the structured fields are invalid and you 08770000 created the structured fields for the resource or print data set 08780000 containing the image, correct the error in the referenced 08790000 structured field and resubmit the print request. Refer to Mixed 08800000 Object Document Content Architecture Reference for more 08810000 information about the structured field. If the structured field 08820000 has no error, the error may be a PSF or printer logic error. If 08830000 you used a program to create the structured fields for the 08840000 resource or print data set containing the image, contact 08850000 your system programmer. 08860000 08870000 If the color space value is unsupported by 08880000 this printer resubmit the print request to a printer 08890000 that does support this color space value. 08900000 08910000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 08920000 to create the structured fields for the print data set or the 08930000 resource with the error, verify that the input to that program 08940000 was valid. If the input was valid, refer to Advanced Function 08950000 Printing: Diagnosis Guide and Print Services Facility/MVS: 08960000 Diagnosis Guide and Reference for assistance in determining the 08970000 source of the problem. If the error involves separator pages or 08980000 the message data set, use the information provided in the User 08990000 response section to correct the error. 09000000 09010000 OPERATOR RESPONSE: If the message appears on the operator's 09020000 console, it indicates that the resource containing the error is 09030000 defined for a separator page or the message data set in the PSF 09040000 startup procedure. Inform your system programmer. 09050000 09060000 PROBLEM DETERMINATION: Items 1, 2, 17, 27. 09070000 09080000 3. On page 211, following the entry for APS805I add: 09090000 09100000 APS806I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 09110000 COLOR VALUE FIELD IN A X'4E' TRIPLET OR SET EXTENDED 09120000 COLOR CONTROL SEQUENCE IS INVALID OR UNSUPPORTED. 09130000 09140000 EXPLANATION: The color value field in a X'4E' triplet or Set 09150000 Extended Color control sequence contained an invalid or 09160000 unsupported value for this printer. 09170000 The X'4E' triplet might have occurred on 09180000 the following structured fields: 09190000 09200000 o a Page Descriptor (PGD), 09210000 o an Object Area Descriptor (OBD) 09220000 09230000 The PGD is contained in an Active Environment Group (AEG) for a 09240000 page or an overlay and the OBD is contained in an Object 09250000 Environment Group(OEG) for a graphics, image or bar code object. 09260000 09270000 The Set Extended Color control sequence is located in a 09280000 Presentation Text Data (PTX) structured field. The structured 09290000 field may be contained in MO:DCA data, an overlay, or a page 09300000 segment; or it may be imbedded in a data set containing line 09310000 data. 09320000 09330000 SYSTEM ACTION: The printer you were using may attempt to print 09340000 the page in error using a substituted color value. The entire 09350000 page may not be 09360000 printed. If the page in error contains any positioning errors, 09370000 then print-error markers may be included on the printed page. 09380000 PSF continues processing of the current data set with the page 09390000 following the page in error, unless the printer reported another 09400000 error that required a more severe PSF recovery action. 09410000 09420000 If the object is in a resource, PSF stops processing the data 09430000 set that uses the resource in error. 09440000 09450000 USER RESPONSE: If the color value is unsupported by 09460000 this printer resubmit the print request to a printer 09470000 that does support this color value. 09480000 09490000 If you created the structured fields for the resource 09500000 or print data set, correct the error in the referenced 09510000 structured field and resubmit the print request. Refer to Mixed 09520000 Object Document Content Architecture Reference for more 09530000 information about the structured field. If the structured field 09540000 has no error, the error may be a PSF or printer logic error. If 09550000 you used a program to create the structured fields for the 09560000 resource or print data set containing the image, contact 09570000 your system programmer. 09580000 09590000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 09600000 to create the structured fields for the print data set or the 09610000 resource with the error, verify that the input to that program 09620000 was valid. If the input was valid, refer to Advanced Function 09630000 Printing: Diagnosis Guide and Print Services Facility/MVS: 09640000 Diagnosis Guide and Reference for assistance in determining the 09650000 source of the problem. If the error involves separator pages or 09660000 the message data set, use the information provided in the User 09670000 response section to correct the error. 09680000 09690000 OPERATOR RESPONSE: If the message appears on the operator's 09700000 console, it indicates that the resource containing the error is 09710000 defined for a separator page or the message data set in the PSF 09720000 startup procedure. Inform your system programmer. 09730000 09740000 PROBLEM DETERMINATION: Items 1, 2, 17, 27. 09750000 09760000 4. On page 215, following the entry for APS813I add: 09770000 09780000 APS814I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 09790000 SHADING OR COVERAGE VALUE IN A X'4E' TRIPLET OR SET 09800000 EXTENDED COLOR CONTROL SEQUENCE IS INVALID. 09810000 09820000 EXPLANATION: The percent coverage, the percent shading or both 09830000 fields in a X'4E' triplet or Set Extended Color control 09840000 sequence contained an invalid value for this printer. 09850000 The X'4E' triplet 09860000 might have occurred on the following structured fields: 09870000 09880000 o a Page Descriptor (PGD), 09890000 o an Object Area Descriptor (OBD) 09900000 09910000 The PGD is contained in an Active Environment Group (AEG) for a 09920000 page or an overlay and the OBD is contained in an Object 09930000 Environment Group(OEG) for a graphics, image or bar code object. 09940000 09950000 The Set Extended Color control sequence is located in a 09960000 Presentation Text Data (PTX) structured field. The structured 09970000 field may be contained in MO:DCA data, an overlay, or a page 09980000 segment; or it may be imbedded in a data set containing line 09990000 data. 10000000 10010000 SYSTEM ACTION: The printer you were using may attempt 10020000 to print the page in error. The entire page may not be 10030000 printed. If the page in error contains any positioning errors, 10040000 then print-error markers may be included on the printed page. 10050000 PSF continues processing of the current data set with the page 10060000 following the page in error, unless the printer reported 10070000 another error that required a more severe PSF recovery action. 10080000 10090000 If the object is in a resource, PSF stops processing the data 10100000 set that uses the resource in error. 10110000 10120000 USER RESPONSE: If the structured fields are invalid and you 10130000 created the structured fields for the resource or print data set 10140000 containing the image, correct the error in the referenced 10150000 structured field and resubmit the print request. Refer to Mixed 10160000 Object Document Content Architecture Reference for more 10170000 information about the structured field. If the structured field 10180000 has no error, the error may be a PSF or printer logic error. If 10190000 you used a program to create the structured fields for the 10200000 resource or print data set containing the image, contact 10210000 your system programmer. 10220000 10230000 If the color space value is unsupported by 10240000 this printer resubmit the print request to a printer 10250000 that does support this color space value. 10260000 10270000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 10280000 to create the structured fields for the print data set or the 10290000 resource with the error, verify that the input to that program 10300000 was valid. If the input was valid, refer to Advanced Function 10310000 Printing: Diagnosis Guide and Print Services Facility/MVS: 10320000 Diagnosis Guide and Reference for assistance in determining the 10330000 source of the problem. If the error involves separator pages or 10340000 the message data set, use the information provided in the User 10350000 response section to correct the error. 10360000 10370000 OPERATOR RESPONSE: If the message appears on the operator's 10380000 console, it indicates that the resource containing the error is 10390000 defined for a separator page or the message data set in the PSF 10400000 startup procedure. Inform your system programmer. 10410000 10420000 PROBLEM DETERMINATION: Items 1, 2, 17, 27. 10430000 10440000 5. On page 223, following the entry for APS837I add: 10450000 10460000 APS838I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 10470000 NUMBER OF BITS SPECIFIED FOR A COLOR COMPONENT IN 10480000 A X'4E' TRIPLET OR SET EXTENDED COLOR CONTROL SEQUENCE 10490000 IS INVALID OR UNSUPPORTED. 10500000 10510000 EXPLANATION: An invalid or unsupported value was specified in 10520000 the Colsize1, Colsize2, Colsize3, or Colsize4 field(s) of a 10530000 X'4E' triplet or a Set Extended Color control sequence for 10540000 this printer. 10550000 10560000 The X'4E' triplet might have occurred on 10570000 the following structured fields: 10580000 10590000 o a Page Descriptor (PGD), 10600000 o an Object Area Descriptor (OBD) 10610000 10620000 The PGD is contained in an Active Environment Group (AEG) for a 10630000 page or an overlay and the OBD is contained in an Object 10640000 Environment Group(OEG) for a graphics, image or bar code object. 10650000 10660000 The Set Extended Color control sequence is located in a 10670000 Presentation Text Data (PTX) structured field. The structured 10680000 field may be contained in MO:DCA data, an overlay, or a page 10690000 segment; or it may be imbedded in a data set containing line 10700000 data. 10710000 10720000 SYSTEM ACTION: The printer you were using may attempt 10730000 to print the page in error. The entire page may not be 10740000 printed. If the page in error contains any positioning errors, 10750000 then print-error markers may be included on the printed page. 10760000 PSF continues processing of the current data set with the page 10770000 following the page in error, unless the printer reported 10780000 another error that required a more severe PSF recovery action. 10790000 10800000 If the object is in a resource, PSF stops processing the data 10810000 set that uses the resource in error. 10820000 10830000 USER RESPONSE: If the structured fields are invalid and you 10840000 created the structured fields for the resource or print data set 10850000 containing the image, correct the error in the referenced 10860000 structured field and resubmit the print request. Refer to Mixed 10870000 Object Document Content Architecture Reference for more 10880000 information about the structured field. If the structured field 10890000 has no error, the error may be a PSF or printer logic error. If 10900000 you used a program to create the structured fields for the 10910000 resource or print data set containing the image, contact 10920000 your system programmer. 10930000 10940000 If the color component is unsupported by 10950000 this printer resubmit the print request to a printer 10960000 that does support this color component. 10970000 10980000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 10990000 to create the structured fields for the print data set or the 11000000 resource with the error, verify that the input to that program 11010000 was valid. If the input was valid, refer to Advanced Function 11020000 Printing: Diagnosis Guide and Print Services Facility/MVS: 11030000 Diagnosis Guide and Reference for assistance in determining the 11040000 source of the problem. If the error involves separator pages or 11050000 the message data set, use the information provided in the User 11060000 response section to correct the error. 11070000 11080000 OPERATOR RESPONSE: If the message appears on the operator's 11090000 console, it indicates that the resource containing the error is 11100000 defined for a separator page or the message data set in the PSF 11110000 startup procedure. Inform your system programmer. 11120000 11130000 PROBLEM DETERMINATION: Items 1, 2, 17, 27. 11140000 11150000 6. On page 226 update the message text and the explanation for 11160000 message APS848I to read as follows: 11170000 11180000 APS848I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE SET 11190000 TEXT COLOR CONTROL SEQUENCE CONTAINS AN INVALID OR 11200000 UNSUPPORTED TEXT COLOR OR PRECISION. 11210000 11220000 EXPLANATION: The Set Text Color (STC) control sequence contains 11230000 an invalid or unsupported value for either the Text Color 11240000 parameter or the Precision parameter. The control sequence is... 11250000 (The rest of the explanation remains as it is written) 11260000 11270000 -----------CHANGES FOR OW21530---------------------------------- 11280000 11290000 1. On page 101 add the following new messages after APS382I. 11300000 11310000 11320000 APS383I THE PRESENTATION SYSTEM SETUP ID SPECIFIED IN THE MMC 11330000 STRUCTURED FIELD (identifier) IS NOT CURRENTLY AVAILABLE 11340000 AT THE DEVICE. THE DATA SET WILL BE HELD BY THE SYSTEM. 11350000 11360000 EXPLANATION: The Presentation System Setup ID in the Medium 11370000 Modification Control (MMC) structured field contains a Setup ID 11380000 that is not currently available at the printer, or the printer 11390000 does not support setup IDs. The MMC structured field is 11400000 contained in the form definition. 11410000 11420000 SYSTEM ACTION: PSF stops processing and printing the data set. 11430000 PSF issues additional messages identifying the processing 11440000 environment when the error was found. PSF releases the current 11450000 data set back to JES and requests that it be held by the 11460000 system. 11470000 11480000 USER RESPONSE: To receive the printed output with the setup ID 11490000 identified, either: 11500000 11510000 o Specify the FORMS keyword on the OUTPUT statement of the 11520000 JCL with a parameter as determined by local procedures or 11530000 11540000 o Request to the operator that the identified setup IDs be 11550000 made available on the printer or 11560000 11570000 o Submit the job to a printer containing the identified setup 11580000 ID. 11590000 11600000 If the setup ID identified is not what you wanted, either: 11610000 11620000 o Specify a form definition containing a different or no 11630000 setup ID or 11640000 11650000 o Modify the form definition to require a different 11660000 presentation system setup ID or remove the use of the 11670000 presentation system setup ID. 11680000 11690000 SYSTEM PROGRAMMER RESPONSE: If this message appears on the 11700000 operator's console, use the information provided in the 11710000 Operator Response section. If the Setup ID is not what you 11720000 wanted, modify the PSF writer procedure as described in the 11730000 User Response section. 11740000 11750000 OPERATOR RESPONSE: If this message appears on the operator's 11760000 console, it indicates that the resource containing the Setup ID 11770000 is defined for a separator page or the message data set in the 11780000 PSF startup procedure. If the Setup ID cannot be made 11790000 available on the printer at all times, then contact your system 11800000 programmer. 11810000 11820000 Refer to the operator's manual for your printer or your post 11830000 processing device to determine how to make the determined Setup 11840000 ID available for use. 11850000 11860000 PROBLEM DETERMINATION: None. 11870000 11880000 11890000 APS384I DATA IN A FORMDEF RESOURCE IS INVALID: THE SET OF 11900000 MODIFICATIONS SPECIFIED IN THE MCC STRUCTURED FIELD 11910000 INCLUDES CONFLICTING PRESENTATION SYSTEM SETUP ID 11920000 VALUES. 11930000 11940000 EXPLANATION: Multiple MMC structured fields referenced by the 11950000 MCC structured field do not use the exact same set of 11960000 Presentation System Setup ID values. 11970000 11980000 SYSTEM ACTION: The form definition containing the error is not 11990000 used, and one of the following occurs: 12000000 12010000 o PSF is not initialized for either the default form 12020000 definition or a form definition specified for printing 12030000 messages or separator pages. 12040000 12050000 o PSF cannot begin printing the data set for a form 12060000 definition specified on a user's JCL OUTPUT statement, and 12070000 tries to print the next data set. 12080000 12090000 PSF issues a message identifying the position of the structured 12100000 field in the form definition. PSF issues additional messages 12110000 identifying the processing environment when the error was 12120000 found. 12130000 12140000 USER RESPONSE: If you created the structured fields for the 12150000 form definition, correct the error and resubmit the print 12160000 request. Refer to Mixed Object Document Content Architecture 12170000 Reference and Advanced Function Presentation: Programming Guide 12180000 and Line Data Reference for more information about the 12190000 structured field. If the structured field has no error, the 12200000 error may be a PSF logic error. If you used a program to 12210000 create the structured fields for the form definition, contact 12220000 your system programmer. 12230000 12240000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 12250000 used to create the structured fields for the form definition 12260000 with the error, verify that the input to that program was 12270000 valid. If the input was valid, refer to Advanced Function 12280000 Printing: Diagnosis Guide and Print Services Facility/MVS: 12290000 Diagnosis Guide and Reference for assistance in determining the 12300000 source of the problem. 12310000 12320000 OPERATOR RESPONSE: If this message appears on the operator's 12330000 console, it indicates that the resource containing the error is 12340000 defined for a separator page, for the message data set, or as 12350000 the default resource for user print data sets in the PSF 12360000 startup procedure. Inform your system programmer. 12370000 12380000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 12390000 12400000 12410000 APS385I DATA IN A FORMDEF RESOURCE IS INVALID: THE 12420000 MODIFICATIONS SPECIFIED IN THE MMC STRUCTURED FIELD 12430000 INCLUDE UNPAIRED 'B4'X AND 'B5'X KEYWORDS. 12440000 12450000 EXPLANATION: The 'B4'X / 'B5'X keywords must be paired in the 12460000 Medium Modification Control (MMC) structured field if 12470000 Presentation System Setup IDs are to be specified. This formdef 12480000 has one or the other keyword but not both or the keyword pairs 12490000 are not adjacent with the 'B4'X keyword first. The MMC 12500000 structured field is contained in the form definition. 12510000 12520000 SYSTEM ACTION: The form definition containing the error is not 12530000 used, and one of the following occurs: 12540000 12550000 o PSF is not initialized for either the default form 12560000 definition or a form definition specified for printing 12570000 messages or separator pages. 12580000 12590000 o PSF cannot begin printing the data set for a form 12600000 definition specified on a user's JCL OUTPUT statement, and 12610000 tries to print the next data set. 12620000 12630000 PSF issues a message identifying the position of the structured 12640000 field in the form definition. PSF issues additional messages 12650000 identifying the processing environment when the error was 12660000 found. 12670000 12680000 USER RESPONSE: If you created the structured fields for the 12690000 form definition, correct the error and resubmit the print 12700000 request. Refer to Mixed Object Document Content Architecture 12710000 Reference and Advanced Function Presentation: Programming Guide 12720000 and Line Data Reference for more information about the 12730000 structured field. If the structured field has no error, the 12740000 error may be a PSF logic error. If you used a program to 12750000 create the structured fields for the form definition, contact 12760000 your system programmer. 12770000 12780000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 12790000 used to create the structured fields for the form definition 12800000 with the error, verify that the input to that program was 12810000 valid. If the input was valid, refer to Advanced Function 12820000 Printing: Diagnosis Guide and Print Services Facility/MVS: 12830000 Diagnosis Guide and Reference for assistance in determining the 12840000 source of the problem. If the error involves separator pages 12850000 or the message data set, use the information provided in the 12860000 User Response section to correct the error. 12870000 12880000 OPERATOR RESPONSE: If this message appears on the operator's 12890000 console, it indicates that the resource containing the error is 12900000 defined for a separator page, for the message data set, or as 12910000 the default resource for user print data sets in the PSF 12920000 startup procedure. Inform your system programmer. 12930000 12940000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 12950000 12960000 2. On page 199 make the following changes to APS770I. 12970000 12980000 Replace the message text for APS770I with the following: 12990000 13000000 APS770I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 13010000 THE COLOR SPACE VALUE IN A X'4E' TRIPLET, SET EXTENDED 13020000 COLOR CONTROL SEQUENCE OR SET PROCESS COLOR DRAWING ORDER 13030000 IS INVALID OR UNSUPPORTED. 13040000 13050000 Replace the first sentence of the Explanation for APS770I 13060000 with the following: 13070000 13080000 EXPLANATION: The color space field in a X'4E' triplet, 13090000 Set Extended Color control sequence or Set Process Color 13100000 drawing order contained an invalid or unsupported value 13110000 for this printer. 13120000 13130000 Add a new paragraph to the end of the EXPLANATION for 13140000 message APS770I: 13150000 13160000 The Set Process Color drawing order is located in a 13170000 Graphics Data (GAD) structured field. The structured 13180000 field may be contained in MO:DCA data, an overlay, or a 13190000 page segment; or it may imbedded in a data set containing 13200000 line data. 13210000 13220000 3. On page 211 make the following changes to message APS806I: 13230000 13240000 Replace the message text: 13250000 APS806I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 13260000 THE COLOR VALUE FIELD IN A X'4E' TRIPLET, SET EXTENDED 13270000 COLOR CONTROL SEQUENCE OR SET PROCESS COLOR DRAWING ORDER 13280000 IS INVALID OR UNSUPPORTED. 13290000 13300000 Replace the first sentence of the Explanation: 13310000 13320000 EXPLANATION: The color value field in a X'4E' triplet, 13330000 Set Extended Color control sequence or Set Process Color 13340000 drawing order contained an invalid or unsupported value 13350000 for this printer. 13360000 13370000 Add a new paragraph to the end of the EXPLANATION: 13380000 13390000 The Set Process Color drawing order is located in a 13400000 Graphics Data (GAD) structured field. The structured 13410000 field may be contained in MO:DCA data, an overlay, or a 13420000 page segment; or it may imbedded in a data set containing 13430000 line data. 13440000 13450000 4. On page 215 make the following changes to message APS814I: 13460000 13470000 Replace the message text: 13480000 APS814I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 13490000 THE SHADING OR COVERAGE VALUE IN A X'4E' TRIPLET, SET 13500000 EXTENDED COLOR CONTROL SEQUENCE OR SET PROCESS COLOR 13510000 DRAWING ORDER IS INVALID OR UNSUPPORTED. 13520000 13530000 Replace the first sentence of the Explanation: 13540000 13550000 EXPLANATION: The percent coverage, the percent 13560000 shading or both fields in a X'4E' triplet, 13570000 Set Extended Color control sequence or Set Process Color 13580000 drawing order contained an invalid or unsupported value 13590000 for this printer. 13600000 13610000 Add a new paragraph to the end of the EXPLANATION: 13620000 13630000 The Set Process Color drawing order is located in a 13640000 Graphics Data (GAD) structured field. The structured 13650000 field may be contained in MO:DCA data, an overlay, or a 13660000 page segment; or it may imbedded in a data set containing 13670000 line data. 13680000 13690000 5. On page 223 make the following changes to message APS838I: 13700000 13710000 Replace the message text: 13720000 APS838I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 13730000 THE NUMBER OF BITS SPECIFIED FOR A COLOR COMPONENT 13740000 IN A X'4E' TRIPLET, SET 13750000 EXTENDED COLOR CONTROL SEQUENCE OR SET PROCESS COLOR 13760000 DRAWING ORDER IS INVALID OR UNSUPPORTED. 13770000 13780000 Replace the first sentence of the Explanation: 13790000 13800000 EXPLANATION: An invalid or unsupported value was 13810000 specified in the Colsize1, Colsize2, Colsize3 or 13820000 Colsize4 field(s) of a X'4E' triplet, 13830000 Set Extended Color control sequence or Set Process Color 13840000 drawing order contained an invalid or unsupported value 13850000 for this printer. 13860000 13870000 Add a new paragraph to the end of the EXPLANATION: 13880000 13890000 The Set Process Color drawing order is located in a 13900000 Graphics Data (GAD) structured field. The structured 13910000 field may be contained in MO:DCA data, an overlay, or a 13920000 page segment; or it may imbedded in a data set containing 13930000 line data. 13940000 13950000 6. On page 287 change the "Explanation" for reason code 0235 13960000 to read as follows. 13970000 13980000 Explanation: This abend is issued by module APSCOPCI - 13990000 APSCOPCI could not get storage for the 14000000 multiple output bin array or the Set-Up 14010000 ID area. 14020000 14030000 -----------CHANGES FOR OW27610---------------------------------- 14040000 14050000 1. On page 253 add APS947I before APS948I. 14060000 14070000 APS947I COMMUNICATION WITH TCP/IP ATTACHED PRINTER(prtnnnn) 14080000 WAS TERMINATED DUE TO PERMANENT HARDWARE ERROR. 14090000 14100000 Explanation: The printer detected a device-inoperative 14110000 condition. PRINTER(prtnnnn) specifies the name of the 14120000 PRINTDEV statement. 14130000 14140000 System Action: Communication with the TCP/IP attached printer 14150000 is ended. PSF stops the printer. This permanent hardware 14160000 error should be corrected before PSF is restarted. 14170000 14180000 User Response: No response is necessary. 14190000 14200000 System Programmer Response: No response is necessary. 14210000 14220000 Operator Response: Consult the person responsible for the 14230000 remote printer. 14240000 14250000 Problem Determination: Items 1, 17, 19 14260000 14270000 2. On page 253 change the System Programmer Response for APS949I 14280000 to read as follows. 14290000 14300000 Verify that the tcpip_name is the TCP/IP address space name. 14310000 This is the TCP/IP started task name that is in the TCP/IP 14320000 profile data set with the TCPIPJOBNAME keyword. Unless the 14330000 TCP/IP address space name was specified on the EXEC 14340000 statement in the PSF writer procedure, then PSF 14350000 will use the default name, TCPIP. Check the ERRNO value in 14360000 IBM TCP/IP for MVS: Application Programming Interface 14370000 Reference. 14380000 14390000 3. On page 290 change abend reason code 264 to read as follows. 14400000 14410000 0264 14420000 14430000 Explanation: This abend is issued by module 14440000 APSCCLR-- 14450000 14460000 APSCCLR was called for a printer failure with an invalid 14470000 action code '22' sense code for a TCP/IP connection. 14480000 14490000 System Action: PSF processing terminates abnormally. 14500000 14510000 System Programmer Response: This PSF abend reason code 14520000 results from a possible logic error in either the microcode 14530000 of the printer or in PSF. Contact your service representative 14540000 in the IBM Support Center or use your electronic link with 14550000 IBM service for assistance regarding this error code. 14560000 14570000 -----------CHANGES FOR OW22894---------------------------------- @11A 14580000 14590000 1. On page 62, change the message text for APS263I: 14600000 14610000 o Change IPO to MPO in message text only. The message explanation 14620000 is correct as is. 14630000 14640000 2. On page 327, delete the documentation for ABEND reason code 0925. 14650000 14660000 14670000 -----------CHANGES FOR OW27622---------------------------------- 14680000 14690000 pg 101 add these new messages after message APS382I: 14700000 14710000 APS389I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 14720000 THE METRIC TECHNOLOGY, THE UNIT BASE OR THE UNITS 14730000 PER UNIT BASE FIELD IS INVALID IN THE X'84' 14740000 TRIPLET ON THE MCF2. 14750000 14760000 EXPLANATION: The metric technology, the unit base, or the 14770000 units per unit base value in the X'84' triplet on the MCF2 14780000 structured field is invalid. 14790000 14800000 SYSTEM ACTION: PSF stops processing the current page. PSF 14810000 attempts to find the end of the current page and resume 14820000 printing on the next page. If unable to find the end of the 14830000 page, PSF stops printing the data set. PSF issues a message 14840000 identifying the position of the structured field in the input 14850000 data stream or resource. PSF issues additional messages 14860000 identifying the processing environment in which the error 14870000 occurred. 14880000 14890000 USER RESPONSE: If you created the structured fields for the 14900000 print data set or the resource, correct the error and resubmit 14910000 the print request. Refer to Mixed Object Document Content 14920000 Architecture Reference for more information about the 14930000 structured field. If the structured field has no error, the 14940000 error may be a PSF logic error. If you used a program to 14950000 create the structured fields for the print data set or the 14960000 resource, contact your system programmer. 14970000 14980000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 14990000 used to create the structured fields for the print data set or 15000000 the resource with the error, verify that the input to that 15010000 program was valid. If the input was valid, refer to Advanced 15020000 Function Printing: Diagnosis Guide and Print Services 15030000 Facility/MVS: Diagnosis Guide and Reference for assistance in 15040000 determining the source of the problem. If the error involves 15050000 separator pages or the message data set, use the information 15060000 provided in the User Response section to correct the error. 15070000 15080000 OPERATOR RESPONSE: If this message displays on the operator's 15090000 console, it indicates that the resource containing the error is 15100000 defined for a separator page, for the message data set, or as 15110000 the default resource for user print data sets in the PSF 15120000 startup procedure. Inform your system programmer. 15130000 15140000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 15150000 15160000 15170000 15180000 APS390I DATA IN A FORMDEF RESOURCE IS INVALID: 15190000 THE FONT UNAVAILABLE EXCEPTION CONTINUATION ACTION 15200000 IS INVALID IN THE X'78' TRIPLET ON THE PFC. 15210000 15220000 EXPLANATION: A document environment group in the current form 15230000 definition contains a Presentation Fidelity Control (PFC) 15240000 structured field with an invalid value specified for the 15250000 font unavailable continuation action. 15260000 15270000 SYSTEM ACTION: The X'78' triplet on the PFC is ignored and 15280000 processing continues. PSF issues additional messages 15290000 identifying the processing environment in which the error 15300000 occurred. 15310000 15320000 USER RESPONSE: If you created the structured fields for the 15330000 form definition, correct the error and resubmit the print 15340000 request. For more information about the structured field, refer 15350000 to Mixed Object Document Content Architecture Reference and 15360000 Advanced Function Presentation: Programming Guide and Line Data 15370000 Reference. If the structured field has no error, the error may 15380000 be a PSF logic error. If you used a program to create the 15390000 structured fields for the form definition, consult your system 15400000 programmer. 15410000 15420000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 15430000 used to create the structured fields for the form definition 15440000 with the error, verify that the input to that program was 15450000 valid. If the input was valid, refer to Advanced Function 15460000 Printing: Diagnosis Guide and Print Services Facility/MVS: 15470000 Diagnosis Guide and Reference for assistance in determining the 15480000 source of the problem. If the error involves separator pages 15490000 or the message data set, use the information provided in the 15500000 User Response section to correct the error. 15510000 15520000 OPERATOR RESPONSE: If this message displays on the operator's 15530000 console, it indicates that the resource containing the error is 15540000 defined for a separator page, for the message data set, or as 15550000 the default resource for user print data sets in the PSF 15560000 startup procedure. Inform your system programmer. 15570000 15580000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 15590000 15600000 15610000 15620000 APS391I THE METRIC TECHNOLOGY AND RESOLUTION IN THE FONT 15630000 DO NOT MATCH THE SPECIFIED VALUES. 15640000 15650000 EXPLANATION: The metric technology and resolution values 15660000 specified in the X'84' triplet on the MCF2 structured field, 15670000 the RESFMT keyword on the OUTPUT statement or by the 15680000 Resource-Management Exit (APSUX07) do not match the 15690000 values in the Font Control (FNC) structured field. The FNC 15700000 structured field is in the font character set. These fields 15710000 are required to match the specified values when the Presentation 15720000 Fidelity Control(PFC) has the Font Fidelity triplet continuation 15730000 rule set to "Stop presentation". The PFC structured field is 15740000 specified in the form definition. 15750000 15760000 SYSTEM ACTION: PSF cannot print the current page. PSF 15770000 attempts to find the end of the current page and resume 15780000 printing on the next page. If unable to find the end of the 15790000 page, PSF stops printing the data set. 15800000 15810000 PSF issues a message identifying the position of the structured 15820000 field in the input data stream or resource. PSF issues 15830000 additional messages identifying the processing environment in 15840000 which the error occurred. 15850000 15860000 USER RESPONSE: Determine whether the font required any 15870000 preprocessing to match the resolution of the device; if so, 15880000 ensure that this was done. For more information about 15890000 converting 240-pel fonts to 300-pel fonts, refer to Print 15900000 Services Facility/MVS: System Programming Guide. If you 15910000 created the structured fields for the font, correct the error 15920000 and resubmit the print request. Refer to Advanced Function 15930000 Printing: Host Font Data Stream Reference for more information 15940000 about the structured field. If the structured field has no 15950000 error, the error may be a PSF logic error. If you used a 15960000 program to create the structured fields for the font, contact 15970000 your system programmer. 15980000 15990000 SYSTEM PROGRAMMER RESPONSE: If the PRINTDEV JCL statement 16000000 in the PSF startup procedure does not specify the correct 16010000 font library for the resolution of the printer, correct it. 16020000 16030000 If an IBM licensed program was used to create the structured 16040000 fields for the font with the error, verify that the input to 16050000 that program was valid. If the input was valid, refer to Mixed 16060000 Object Document Content Architecture Reference and Print 16070000 Services Facility/MVS: System Programming Guide for assistance 16080000 in determining the source of the problem. If the error 16090000 involves separator pages or the message data set, use the 16100000 information provided in the User Response section to correct 16110000 the error. 16120000 16130000 OPERATOR RESPONSE: If this message displays on the operator's 16140000 console, it indicates that the resource containing the error is 16150000 defined for a separator page or the message data set in the PSF 16160000 startup procedure. Inform your system programmer. 16170000 16180000 PROBLEM DETERMINATION: Items 1, 2, 3, 8, 13, 17, 19. 16190000 16200000 16210000 pg 301 add new abend codes 16220000 16230000 0730 16240000 16250000 EXPLANATION: This abend is issued by module 16260000 APSRMPSG-- 16270000 The module was unable to GETMAIN storage for the APSRSWRK 16280000 control block. PSF cannot execute without sufficient 16290000 storage space to build its basic control blocks. 16300000 16310000 SYSTEM ACTION: PSF processing terminates abnormally. This 16320000 PSF abend reason code indicates that the REGION size should 16330000 be increased. If the print request is processing in 16340000 direct-printing mode, this REGION size is for the job or 16350000 step containing the request. If the print request is 16360000 processing in deferred-printing mode, increase the REGION 16370000 parameter used in the PSF startup procedure. 16380000 16390000 0736 16400000 16410000 EXPLANATION: This abend is issued by module 16420000 APSRMFNT-- 16430000 The module was unable to GETMAIN storage for the APSRSWRK 16440000 control block. PSF cannot execute without sufficient 16450000 storage space to build its basic control blocks. 16460000 16470000 SYSTEM ACTION: PSF processing terminates abnormally. This 16480000 PSF abend reason code indicates that the REGION size should 16490000 be increased. If the print request is processing in 16500000 direct-printing mode, this REGION size is for the job or 16510000 step containing the request. If the print request is 16520000 processing in deferred-printing mode, increase the REGION 16530000 parameter used in the PSF startup procedure. 16540000 16550000 0740 16560000 16570000 EXPLANATION: This abend is issued by module 16580000 APSRMOVL-- 16590000 The module was unable to GETMAIN storage for the APSRSWRK 16600000 control block. PSF cannot execute without sufficient 16610000 storage space to build its basic control blocks. 16620000 16630000 SYSTEM ACTION: PSF processing terminates abnormally. This 16640000 PSF abend reason code indicates that the REGION size should 16650000 be increased. If the print request is processing in 16660000 direct-printing mode, this REGION size is for the job or 16670000 step containing the request. If the print request is 16680000 processing in deferred-printing mode, increase the REGION 16690000 parameter used in the PSF startup procedure. 16700000 16710000 pg 312 add the following new abend code 16720000 16730000 0959 16740000 16750000 EXPLANATION: This abend is issued by module 16760000 APSLINIT-- 16770000 The module was unable to GETMAIN storage for the Library 16780000 Link List. PSF cannot execute without sufficient 16790000 storage space to build its basic control blocks. 16800000 16810000 SYSTEM ACTION: PSF processing terminates abnormally. This 16820000 PSF abend reason code indicates that the REGION size should 16830000 be increased. If the print request is processing in 16840000 direct-printing mode, this REGION size is for the job or 16850000 step containing the request. If the print request is 16860000 processing in deferred-printing mode, increase the REGION 16870000 parameter used in the PSF startup procedure. 16880000 16890000 -----------CHANGES FOR OW27623---------------------------------- 16900000 16910000 1. On page 47, replace the Explanation for APS211I. 16920000 16930000 Explanation: PSF/MVS is included in the base code of OS/390 to 16940000 allow you to print only BookManager softcopy BOOKs created by 16950000 use of BookManager BUILD/MVS and viewable by use of BookManager 16960000 READ/MVS. Because PSF/MVS is not enabled for full function, it 16970000 cannot print data sets other than softcopy BOOKs. For you to be 16980000 able to print other data sets, your system programmer must 16990000 enable PSF/MVS. 17000000 17010000 The data set you tried to print did not contain the identifier 17020000 that BookManager generates to identify a softcopy BOOK so that 17030000 you could print it with OS/390 Softcopy Print. 17040000 17050000 2. On page 48, replace the System Programmer Response for 17060000 APS211I. 17070000 17080000 System Programmer Response: If PSF is running on a version of 17090000 MVS earlier than OS/390 Version 1 Release 2, or if the user is 17100000 trying to print a valid BookManager BOOK, consult IBM service. 17110000 If PSF is running on OS/390 Version 1 Release 2 or later and 17120000 you have a PSF license, ensure that the PARMLIB contains a 17130000 correct PSF PRODUCT statement and that PSF has been restarted 17140000 since this product statement was put in the PARMLIB. 17150000 17160000 3. On page 51 add the following new message. 17170000 17180000 APS223I A FORMDEF RESOURCE REQUESTED ENHANCED N_UP AND A 17190000 CONFLICTING VALUE FOR DUPLEX WAS SPECIFIED ON 17200000 THE OUTPUT STATEMENT. 17210000 17220000 Explanation: When enhanced N_UP is requested, the duplex 17230000 keyword on the OUTPUT statement cannot be used to change from 17240000 duplex (specified in the formdef) to simplex or vice versa. The 17250000 reason is that with enhanced N_UP, the Page Position (PGP) 17260000 Format 2 structured field specifies the partition number and 17270000 sheet side for each page placed on a sheet. If the duplex value 17280000 is changed from duplex to simplex or vice versa, PSF/MVS does 17290000 not have the information it needs to place the pages. 17300000 17310000 The only valid options for the duplex keyword when enhanced N_UP 17320000 is specified in the formdef are: 17330000 17340000 If the formdef requests normal or tumble duplex, you may 17350000 specify either duplex=normal or duplex=tumble on the output 17360000 statement. 17370000 17380000 If the formdef requests simplex, you may specify duplex=no 17390000 on the output statement. 17400000 17410000 System Action: PSF stops processing the current data set and 17420000 issues additional messages that identify the processing 17430000 environment when the error was found. 17440000 17450000 User Response: Resubmit the job without requesting the duplex 17460000 keyword on the output statement. 17470000 17480000 System Programmer Response: None 17490000 17500000 Operator Response: None 17510000 17520000 Problem Determination: Items 12, 17, 19. 17530000 17540000 17550000 4. On page 163, change the message description for APS614I. 17560000 (This message was added by apar OW24771.) 17570000 17580000 APS614I THE VALUE SPECIFIED FOR THE keyword KEYWORD ON THE 17590000 OUTPUT STATEMENT IS NOT VALID. 17600000 17610000 Explanation: The value given for the indicated keyword 17620000 contained embedded blanks or too many decimal digits or 17630000 it specifies an unrecognized unit. 17640000 17650000 System Action: The data set is not printed. 17660000 17670000 User Response: Correct the specification for the keyword and 17680000 resubmit the job. 17690000 17700000 System Programmer Response: If the error is on an OUTPUT 17710000 statement for a separator page or the message data set, 17720000 correct the specification for the keyword in the PSF 17730000 startup procedure and restart the FSA. 17740000 17750000 Operator Response: No response is necessary. 17760000 17770000 Problem Determination: Items 2, 3. 17780000 17790000 17800000 5. On page 182 add the following new message. 17810000 17820000 APS730I THE SUM OF THE OUTPUT AND/OR PRINTDEV STATEMENT MEDIUM 17830000 OVERLAYS AND MEDIUM MAP OVERLAYS FOR A PHYSICAL PAGE 17840000 EXCEEDS WHAT THE PRINTER CAN SUPPORT. 17850000 17860000 Explanation: When the number of overlays specified in the 17870000 Medium Modification Control (MMC) structured field and the 17880000 number of medium overlays specified on the OUTPUT and / or 17890000 PRINTDEV statement are added, the total exceeds what this 17900000 printer can support on a physical page (one side of a sheet). 17910000 The MMC structured field is contained in the form definition. 17920000 17930000 The limit for the total number of overlays depends on the 17940000 printer you use. 17950000 17960000 System Action: The data set that was being processed at the 17970000 time of the error is marked unprintable and is terminated. 17980000 PSF will release the current data set back to JES and will 17990000 request that it be held by the system. 18000000 18010000 User Response: Change the output class for the next 18020000 submission. Consult the system operator to have the print 18030000 request released to a printer that can print the total 18040000 number of overlays on that page. If you do not have access 18050000 to a printer that can support that number of overlays on a 18060000 page then the number of overlays will need to be decreased. 18070000 If you created the form definition that contains 18080000 the MMC structured field, you will have to remove one or more of 18090000 the overlays, depending on how many OUTPUT / PRINTDEV statement 18100000 medium overlays were specified. Refer to Mixed Object Document 18110000 Content Architecture Reference for more information about the 18120000 structured field. Resubmit the print request. If the total 18130000 number of user overlays and OUTPUT / PRINTDEV statement medium 18140000 overlays is less than or equal to what this printer should 18150000 support the error may be a PSF logic error. 18160000 18170000 System Programmer Response: If the error involves separator 18180000 pages or the message data set, use the information provided in 18190000 the User Response section to correct the error. 18200000 18210000 Operator Response: If this message displays on the operator's 18220000 console, it indicates that the resource containing the error is 18230000 defined for a separator page or the message data set in the PSF 18240000 startup procedure. Inform your system programmer. 18250000 18260000 Problem Determination: Items 2, 17, 28. 18270000 18280000 -----------CHANGES FOR OW29526---------------------------------- 18290000 18300000 pg 311, Add the following new abend: 18310000 18320000 0606 18330000 18340000 EXPLANATION: This abend is issue by module 18350000 APSERRM-- 18360000 APSERRM detected that the printer is reporting an 18370000 excessive number of NACKs in response 18380000 to the I/O issued for performing recovery. 18390000 18400000 SYSTEM ACTION: PSF processing terminates abnormally. 18410000 18420000 SYSTEM PROGRAMMING RESPONSE: This PSF abend could indicate 18430000 a logic error in the printer microcode. Contact your 18440000 service representaive for the printer involved. 18450000 18460000 -----------CHANGES FOR OW29646---------------------------------- 18470000 18480000 Update the Operator Response for message APS730I. This 18490000 message was added by APAR OW27623. 18500000 18510000 Operator Response: If you are running under Job Entry 18520000 Subsystem (JES), use the JES data-set release commands 18530000 to release the data set to a printer which can handle 18540000 a larger number of medium overlays. For a JES command to 18550000 release the data set for printing, refer to the publication 18560000 containing JES commands for your operating system. 18570000 18580000 -----------CHANGES FOR OW30000 --------------------------------- 18590000 18600000 1. On page 151, remove message APS559I. 18610000 18620000 -----------CHANGES FOR OW30255---------------------------------- 18630000 18640000 1. On page 47, replace the complete text for APS211I. 18650000 18660000 APS211I THE PRINT DATA SET IS NOT RECOGNIZED AS A SOFTCOPY BOOK. 18670000 PSF IS ENABLED ONLY FOR SOFTCOPY PRINT. 18680000 18690000 Explanation: PSF/MVS is included in the base code of OS/390 R2 18700000 and later to allow you to print only BookManager softcopy BOOKs 18710000 created by use of BookManager BUILD/MVS and viewable by use of 18720000 BookManager READ/MVS. Because PSF/MVS is NOT ENABLED for FULL 18730000 function, it cannot print data sets other than softcopy BOOKs. 18740000 For you to be able to print other data sets, your system 18750000 programmer must enable PSF/MVS. 18760000 18770000 The data set you tried to print did not contain the identifier 18780000 that BookManager generates to identify a softcopy BOOK so that 18790000 you could print it with OS/390 Softcopy Print. 18800000 18810000 System Action: PSF stops processing the data set. The message 18820000 is followed by another message, such as APS225I, describing 18830000 what PSF has done with the data set. 18840000 18850000 User Response: If you think FULL function of PSF is ENABLED, 18860000 or that you are receiving this message in error, consult 18870000 your system programmer. 18880000 18890000 System Programmer Response: To be able to print Non-Softcopy 18900000 BOOKs, PSF MUST be ENABLED for FULL function. 18910000 This is accomplished by including the proper PRODUCT statement 18920000 in PARMLIB member IFAPRD00 and then issuing SET PROD=00 on the 18930000 operator's console. After ENABLING PSF, make sure that the PSF 18940000 STARTED TASK is CANCELLED, and then RESTARTED. 18950000 18960000 If the user is receiving this message for a SOFTCOPY BOOK, 18970000 contact your service representative in the IBM SUPPORT 18980000 CENTER or use your electronic link with IBM service for 18990000 assistance regarding this message. 19000000 19010000 Operator Response: No response is necessary. 19020000 19030000 Problem Determination: Items 1, 2, 13, 17,31. 19040000 19050000 -----------CHANGES FOR OW29924---------------------------------- 19060000 19070000 Update the Explanation & System Programmer response for message 19080000 APS209I: 19090000 19100000 EXPLANATION: Installation exit APSUX07 requested that the media 19110000 origin be changed to match the 3800 media origin, but the form 19120000 definition specified capabilities that are not supported by the 19130000 3800, such as N_UP or Presentation System Setup IDs. These 19140000 functions are not acceptable when the media origin is being 19150000 overridden. 19160000 19170000 SYSTEM PROGRAMMER RESPONSE: Refer to the PSF/MVS System 19180000 Programming Guide for functions that aren't available with the 19190000 media origin override. 19200000 19210000 -----------CHANGES FOR OW26734---------------------------------- 19220000 19230000 1. Modify the abend reason code 2E6 on page 300 to read as 19240000 follows. 19250000 19260000 02E6 19270000 19280000 EXPLANATION: This abend is issued by module APSCPRCT-- 19290000 APSCPRCT detected that the page counter received from the 19300000 printer does not match the PSF simulated received page counter. 19310000 Either the printer did not increment the page counter by 1 or it 19320000 is a PSF logic error. 19330000 19340000 SYSTEM ACTION: PSF processing terminates abnormally. 19350000 19360000 SYSTEM PROGRAMMER RESPONSE: This PSF abend reason code results 19370000 from a possible logic error in either the microcode of the 19380000 printer or in PSF. Contact your service representative in the 19390000 IBM Support Center or use your electronic link with IBM service 19400000 for assistance regarding this error code. 19410000 19420000 2. Add the new abend reason code 663 on page 317 after abend 19430000 reason code 662. 19440000 19450000 0663 19460000 19470000 EXPLANATION: This abend is issued by module APSERRM-- 19480000 APSERRM called APSCPRCT to determine the transaction in error 19490000 and APSCPRCT was unable to do so. 19500000 19510000 SYSTEM ACTION: PSF processing terminates abnormally. 19520000 19530000 SYSTEM PROGRAMMER RESPONSE: This PSF abend reason code results 19540000 from a possible logic error in either the microcode of the 19550000 printer or in PSF. Contact your service representative in the 19560000 IBM Support Center or use your electronic link with IBM 19570000 service for assistance regarding this error code. 19580000 19590000 19600000 -----------CHANGES FOR OW29990---------------------------------- 19610000 19620000 Add the following new message: 19630000 19640000 APS499I DATA IN AN INPUT RECORD IS INVALID: THE ORIENTATION 19650000 FIELD IN AN INCLUDE PAGE OVERLAY COMMAND CONTAINS AN 19660000 INVALID VALUE. 19670000 19680000 EXPLANATION: The OvlyOrent field in the Include Page 19690000 Overlay(IPO) command has an invalid value. The IPO structured 19700000 field is contained in a MO:DCA document. 19710000 19720000 SYSTEM ACTION: The printer you were using may attempt to print 19730000 the page in error. The entire page may not be printed. If the 19740000 page in error contains any positioning errors, then print-error 19750000 markers may be included on the printed page. PSF continues 19760000 processing the current data set with the page following the 19770000 page in error, unless the printer reported another error that 19780000 required a more severe PSF recovery action. 19790000 19800000 USER RESPONSE: If you created the structured fields, correct 19810000 the error and resubmit the print request. Refer to Mixed 19820000 Object Document Content Architecture Reference for more 19830000 information about the structured field. If the structured 19840000 field has no error, the error may be a PSF or printer logic 19850000 error. If you used a program to create the structured fields 19860000 contact your system programmer. 19870000 19880000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 19890000 used to create the structured fields for the page with the 19900000 error, verify that the input to that program was valid. If 19910000 the input was valid, refer to Advanced Function Printing: 19920000 Diagnosis Guide and Print Services Facility/MVS Diagnosis Guide 19930000 and Reference for assistance in determining the source of the 19940000 problem. If the error involves separator pages or the 19950000 message data set, use the information provided in the User 19960000 Response section to correct the error. 19970000 19980000 OPERATOR RESPONSE: If this message displays on the operator's 19990000 console, it indicates that the error occurred on a separator 20000000 page or the message data set in the PSF startup procedure. 20010000 Inform your system programmer. 20020000 20030000 PROBLEM DETERMINATION: Items 2, 3, 8, 13, 17. 20040000 20050000 -----------CHANGES FOR OW29992---------------------------------- 20060000 20070000 1. On page 121, add the following message 20080000 20090000 APS445I PRINTER(prtnnn) IS UNUSABLE - ASSIGNED TO ANOTHER SYSTEM 20100000 20110000 EXPLANATION: PSF attempted to issue I/O to the printer, but the 20120000 printer was assigned (reserved) to another system. The 20130000 printer multi-host feature was enabled which causes the 20140000 printer to enforce that only one system can use the printer at 20150000 a time. The printer detected and reported the error with an 20160000 action code X'25' (sense byte 2). For more information about 20170000 this error, refer to the printer publications for the printer 20180000 that reported this error. 20190000 20200000 SYSTEM ACTION: PSF issues this message and terminates with an 20210000 abend 024 RCE33 or abend024 RCE35. 20220000 20230000 SYSTEM PROGRAMMER RESPONSE: If sharing of the printer among 20240000 multiple PSF/MVS hosts is not needed, disable the multi-host 20250000 feature at the printer console. For more information 20260000 concerning the sharing of a printer among multiple PSFs, refer 20270000 to the PSF/MVS System Programming Guide. 20280000 20290000 OPERATOR RESPONSE: Determine which system the printer is 20300000 assigned to and, when appropriate, vary the printer offline 20310000 from that system and vary the printer online to the desired 20320000 system. Restart PSF. 20330000 20340000 PROBLEM DETERMINATION: Items 1 20350000 20360000 20370000 2. On page 135, add the following message 20380000 20390000 APS479I PRINTER(prtnnn) IS UNUSABLE-NOT ASSIGNED TO THIS SYSTEM 20400000 20410000 EXPLANATION: PSF attempted to issue I/O to the printer, but the 20420000 printer was not assigned (reserved) to this system. The 20430000 printer multi-host feature was enabled which causes the 20440000 printer to enforce that only one PSF can use the printer at 20450000 a time. The printer detected and reported the error with an 20460000 action code X'24' (sense byte 2). For more information about 20470000 this error, refer to the printer publications for the printer 20480000 that reported this error. 20490000 20500000 SYSTEM ACTION: PSF issues this message and terminates with an 20510000 abend 024 RCE34 or abend024 RCE36. 20520000 20530000 SYSTEM PROGRAMMER RESPONSE: If sharing of the printer among 20540000 multiple PSF/MVS hosts is not needed, disable the multi-host 20550000 feature at the printer console. For more information 20560000 concerning the sharing of a printer among multiple PSFs, refer 20570000 to the PSF/MVS System Programming Guide. 20580000 20590000 OPERATOR RESPONSE: Determine which system the printer should 20600000 be assigned to and, when available, vary the printer online to 20610000 the system. This may require the printer be varied offline 20620000 from another system. Restart PSF. 20630000 20640000 PROBLEM DETERMINATION: Items 1 20650000 20660000 20670000 3. On page 346 add new abend reason code 0E33 described as 20680000 follows. 20690000 20700000 0E33 20710000 20720000 Explanation: This abend is issued by module APSERRM 20730000 20740000 PSF attempted to do I/O to a printer that was assigned 20750000 (reserved) to another system. 20760000 20770000 System Action: PSF processing terminates abnormally. No 20780000 system dump is generated. 20790000 20800000 System Programmer Response: This PSF abend reason code 20810000 indicates a probable incorrect operational procedure. Refer 20820000 to the associated APS445I message to correct this error. 20830000 20840000 20850000 4. On page 346 add new abend reason code 0E34 described as 20860000 follows. 20870000 20880000 0E34 20890000 20900000 Explanation: This abend is issued by module APSERRM 20910000 20920000 PSF attempted to do I/O to a printer that was not assigned 20930000 (reserved) to the system. 20940000 20950000 System Action: PSF processing terminates abnormally. No 20960000 system dump is generated. 20970000 20980000 System Programmer Response: This PSF abend reason code 20990000 indicates a probable incorrect operational procedure. Refer 21000000 to the associated APS479I message to correct this error. 21010000 21020000 21030000 5. On page 346 add new abend reason code 0E35 described as 21040000 follows. 21050000 21060000 0E35 21070000 21080000 Explanation: This abend is issued by module APSEATCD 21090000 21100000 PSF attempted to do I/O to a printer that was assigned 21110000 (reserved) to another system. 21120000 21130000 System Action: PSF processing terminates abnormally. No 21140000 system dump is generated. 21150000 21160000 System Programmer Response: This PSF abend reason code 21170000 indicates a probable incorrect operational procedure. Refer 21180000 to the associated APS445I message to correct this error. 21190000 21200000 21210000 6. On page 346 add new abend reason code 0E36 described as 21220000 follows. 21230000 21240000 0E36 21250000 21260000 Explanation: This abend is issued by module APSEATCD 21270000 21280000 PSF attempted to do I/O to a printer that was not assigned 21290000 (reserved) to the system. 21300000 21310000 System Action: PSF processing terminates abnormally. No 21320000 system dump is generated. 21330000 21340000 System Programmer Response: This PSF abend reason code 21350000 indicates a probable incorrect operational procedure. Refer 21360000 to the associated APS479I message to correct this error. 21370000 21380000 21390000 -----------CHANGES FOR OW31717---------------------------------- 21400000 21410000 On page 6, add the following message 21420000 21430000 APS020I PRINTING TERMINATED BECAUSE RECOVERY IS INHIBITED. 21440000 21450000 EXPLANATION: An exception occurred for which the normal PSF 21460000 recovery is to resend pages to the printer which may have 21470000 already printed. APSUX07 specified that this recovery should 21480000 not be performed. 21490000 21500000 SYSTEM ACTION: The current print job is terminated. 21510000 21520000 USER RESPONSE: Resubmit the print job to reprint the portion 21530000 of the print data which was not complete, if needed. 21540000 21550000 SYSTEM PROGRAMMER RESPONSE: No response is required. 21560000 21570000 OPERATOR RESPONSE: No response is required. 21580000 21590000 PROBLEM DETERMINATION: Items 2, 3, 8 21600000 21610000 21620000 On page 17, add the following messages 21630000 21640000 APS080I INHIBIT RECOVERY WAS IGNORED BECAUSE IT WAS NOT 21650000 SPECIFIED FOR THE FIRST DATA SET OF THE JOB. 21660000 21670000 EXPLANATION: XTP7IHIB was set off for the first data set of the 21680000 job, but APSUX07 set it on for a subsequent step of the job. 21690000 PSF must perform the same level recovery for the entire job. 21700000 21710000 SYSTEM ACTION: Recovery is allowed for the entire job. 21720000 21730000 USER RESPONSE: Notify your system programmer. 21740000 21750000 SYSTEM PROGRAMMER RESPONSE: Change exit APSUX07 so that it sets 21760000 XTP7IHIB the same for each data set of a job. 21770000 21780000 OPERATOR RESPONSE: No response is required. 21790000 21800000 PROBLEM DETERMINATION: Items 2, 3, 8 21810000 21820000 21830000 APS081I RECOVERY IS INHIBITED BECAUSE IT WAS SPECIFIED FOR THE 21840000 THE FIRST DATA SET OF THE JOB. 21850000 21860000 EXPLANATION: PSF exit APSUX07 set XTP7IHIB on for the first data 21870000 set of the job, but not for a susbsequent step of the job. PSF 21880000 must perform the same level recovery for the entire job. 21890000 21900000 SYSTEM ACTION: Recovery is inhibited for the entire job. 21910000 21920000 USER RESPONSE: Notify your system programmer. 21930000 21940000 SYSTEM PROGRAMMER RESPONSE: Change exit APSUX07 so that it sets 21950000 XTP7IHIB the same for each data set of a job. 21960000 21970000 OPERATOR RESPONSE: No response is required. 21980000 21990000 PROBLEM DETERMINATION: Items 2, 3, 8 22000000 22010000 -----------CHANGES FOR OW33942---------------------------------- 22020000 22030000 1. On page 252 add message APS942I. 22040000 22050000 APS942I AUTOMATIC RESOLUTION MODE NOT SUPPORTED WHEN ATTACHED 22060000 TO EITHER DPF OR RPM3. SWITCH THE PRINTER OUT OF 22070000 AUTOMATIC RESOLUTION MODE. 22080000 22090000 Explanation: PSF is connected to the printer with an 22100000 intermediate device of either DPF or RPM3 and the printer 22110000 is in automatic resolution mode. This configuration is not 22120000 supported. 22130000 22140000 System Action: The PSF FSA for the printer is terminated with 22150000 an abend 024 and abend reason code 0243. 22160000 22170000 User Response: No response is necessary. 22180000 22190000 System Programmer Response: Switch the printer out of automatic 22200000 resolution mode. 22210000 22220000 Operator Response: Inform your system programmer that this 22230000 error occurred. 22240000 22250000 Problem Determination: 1, 18 22260000 22270000 2. On page 289 add abend reason code 245 after abend reason 22280000 code 242. 22290000 22300000 0245 22310000 22320000 Explanation: This abend is issued by module 22330000 APSCOPCI-- 22340000 APSCOPCI detected that PSF was connected to the printer with 22350000 an intermediate device of either DPF or RPM3 and the 22360000 printer was in automatic resolution mode. 22370000 22380000 System Action: PSF processing terminates abnormally. 22390000 22400000 System Programmer Response: This PSF abend reason code 22410000 indicates that the printer was in automatic resolution mode 22420000 and that PSF was connected to the printer via DPF or RPM3. 22430000 DPF and RPM3 do not support a printer in automatic resolution 22440000 mode. Switch the printer out of automatic resolution mode. 22450000 22460000 -----------CHANGES FOR OW24360---------------------------------- 22470000 22480000 Add the following new messages to the PSF Messages section 22490000 starting on page 5. 22500000 22510000 ********************************************************** 22520000 22530000 APS123I GROUP LEVEL MEDIUM FINISHING REQUESTED BUT THE PRINTER 22540000 DOES NOT SUPPORT GROUP LEVEL MEDIUM FINISHING. THE PROCESSING 22550000 OF THE DATA SET CONTINUES WITHOUT GROUP LEVEL MEDIUM FINISHING. 22560000 22570000 EXPLANATION: A document environment group in the current form 22580000 definition contains a Medium Finishing Control (MFC) structured 22590000 field but the printer does not support group level MFCs. 22600000 22610000 SYSTEM ACTION: The MFC is ignored and processing continues. 22620000 PSF issues additional messages identifying the processing 22630000 environment in which the error occurred. 22640000 22650000 USER RESPONSE: If you created the structured fields for the 22660000 form definition, correct the error and resubmit the print 22670000 request. For more information about the structured field, refer 22680000 to Mixed Object Document Content Architecture Reference. 22690000 If the structured field has no error, the error may 22700000 be a PSF logic error. If you used a program to create the 22710000 structured fields for the form definition, consult your system 22720000 programmer. 22730000 22740000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 22750000 used to create the structured fields for the form definition 22760000 with the error, verify that the input to that program was 22770000 valid. If the input was valid, refer to Advanced Function 22780000 Printing: Diagnosis Guide and Print Services Facility/MVS: 22790000 Diagnosis Guide and Reference for assistance in determining the 22800000 source of the problem. If the error involves separator pages 22810000 or the message data set, use the information provided in the 22820000 User Response section to correct the error. 22830000 22840000 OPERATOR RESPONSE: If this message displays on the operator's 22850000 console, it indicates that the resource containing the error is 22860000 defined for a separator page, for the message data set, or as 22870000 the default resource for user print data sets in the PSF 22880000 startup procedure. Inform your system programmer. 22890000 22900000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 22910000 22920000 ********************************************************** 22930000 22940000 APS128I SHEET LEVEL MEDIUM FINISHING REQUESTED BUT THE PRINTER 22950000 DOES NOT SUPPORT SHEET LEVEL MEDIUM FINISHING. THE PROCESSING 22960000 OF THE DATA SET CONTINUES WITHOUT SHEET LEVEL MEDIUM FINISHING. 22970000 22980000 EXPLANATION: A medium map in the current form definition contains 22990000 a Medium Finishing Control (MFC) structured field but the printer 23000000 does not support medium level MFCs. 23010000 23020000 SYSTEM ACTION: The MFC is ignored and processing continues. 23030000 PSF issues additional messages identifying the processing 23040000 environment in which the error occurred. 23050000 23060000 USER RESPONSE: If you created the structured fields for the 23070000 form definition, correct the error and resubmit the print 23080000 request. For more information about the structured field, refer 23090000 to Mixed Object Document Content Architecture Reference. 23100000 If the structured field has no error, the error may 23110000 be a PSF logic error. If you used a program to create the 23120000 structured fields for the form definition, consult your system 23130000 programmer. 23140000 23150000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 23160000 used to create the structured fields for the form definition 23170000 with the error, verify that the input to that program was 23180000 valid. If the input was valid, refer to Advanced Function 23190000 Printing: Diagnosis Guide and Print Services Facility/MVS: 23200000 Diagnosis Guide and Reference for assistance in determining the 23210000 source of the problem. If the error involves separator pages 23220000 or the message data set, use the information provided in the 23230000 User Response section to correct the error. 23240000 23250000 OPERATOR RESPONSE: If this message displays on the operator's 23260000 console, it indicates that the resource containing the error is 23270000 defined for a separator page, for the message data set, or as 23280000 the default resource for user print data sets in the PSF 23290000 startup procedure. Inform your system programmer. 23300000 23310000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 23320000 23330000 ********************************************************** 23340000 23350000 APS241I SYSTEM ACTION TAKEN: THE ERRORS OCCURRED DURING PROCESSING 23360000 OF FINISHING OPERATION TRIPLETS. THESE FINISHING OPERATION 23370000 TRIPLETS WILL NOT BE USED IN THE PROCESSING OF THE DATA 23380000 SET. THE PROCESSING OF THE DATA SET CONTINUES. 23390000 23400000 EXPLANATION: A finishing operation triplet is invalid or forms 23410000 an invalid request because it is not compatible with other 23420000 triplets in the same request. The triplet is not used to 23430000 process this data set. Informational messages preceding this message 23440000 explain why the finishing operation triplet could not be used. 23450000 23460000 SYSTEM ACTION: The triplet is ignored and processing continues. 23470000 PSF issues additional messages identifying the processing 23480000 environment in which the error occurred. 23490000 23500000 USER RESPONSE: If you created the structured fields for the 23510000 form definition, correct the error and resubmit the print 23520000 request. For more information about the structured field, refer 23530000 to Mixed Object Document Content Architecture Reference. 23540000 If the structured field has no error, the error may 23550000 be a PSF logic error. If you used a program to create the 23560000 structured fields for the form definition, consult your system 23570000 programmer. 23580000 23590000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 23600000 used to create the structured fields for the form definition 23610000 with the error, verify that the input to that program was 23620000 valid. If the input was valid, refer to Advanced Function 23630000 Printing: Diagnosis Guide and Print Services Facility/MVS: 23640000 Diagnosis Guide and Reference for assistance in determining the 23650000 source of the problem. If the error involves separator pages 23660000 or the message data set, use the information provided in the 23670000 User Response section to correct the error. 23680000 23690000 OPERATOR RESPONSE: If this message displays on the operator's 23700000 console, it indicates that the resource containing the error is 23710000 defined for a separator page, for the message data set, or as 23720000 the default resource for user print data sets in the PSF 23730000 startup procedure. Inform your system programmer. 23740000 23750000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 23760000 23770000 ********************************************************** 23780000 23790000 APS392I DATA IN A FORMDEF RESOURCE IS INVALID: THE SCOPE VALUE 23800000 IN THE MFC IS INVALID. EITHER DOCUMENT LEVEL OR PRINT 23810000 FILE LEVEL FINISHING WAS SPECIFIED IN THE MEDIUM MAP OR 23820000 MEDIUM LEVEL FINISHING WAS SPECIFIED IN THE DEG. 23830000 23840000 EXPLANATION: Either a document environment group or a medium 23850000 map in the current form definition contains a Medium Finishing 23860000 Control (MFC) structured field with an invalid value specified 23870000 for the scope. 23880000 23890000 SYSTEM ACTION: The MFC is ignored and processing continues. 23900000 PSF issues additional messages identifying the processing 23910000 environment in which the error occurred. 23920000 23930000 USER RESPONSE: If you created the structured fields for the 23940000 form definition, correct the error and resubmit the print 23950000 request. For more information about the structured field, refer 23960000 to Mixed Object Document Content Architecture Reference. 23970000 If the structured field has no error, the error may 23980000 be a PSF logic error. If you used a program to create the 23990000 structured fields for the form definition, consult your system 24000000 programmer. 24010000 24020000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was 24030000 used to create the structured fields for the form definition 24040000 with the error, verify that the input to that program was 24050000 valid. If the input was valid, refer to Advanced Function 24060000 Printing: Diagnosis Guide and Print Services Facility/MVS: 24070000 Diagnosis Guide and Reference for assistance in determining the 24080000 source of the problem. If the error involves separator pages 24090000 or the message data set, use the information provided in the 24100000 User Response section to correct the error. 24110000 24120000 OPERATOR RESPONSE: If this message displays on the operator's 24130000 console, it indicates that the resource containing the error is 24140000 defined for a separator page, for the message data set, or as 24150000 the default resource for user print data sets in the PSF 24160000 startup procedure. Inform your system programmer. 24170000 24180000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 24190000 24200000 ********************************************************** 24210000 24220000 APS393I THE INPUT BIN SPECIFIED IN THE MMC STRUCTURED FIELD OR 24230000 ON THE OUTPUT STATEMENT IS AN INSERTER BIN AND IS 24240000 DISABLED. AN ALTERNATIVE BIN WAS SUBSTITUTED. 24250000 24260000 EXPLANATION: The Medium Modification Control (MMC) structured 24270000 field or the output statement requested an input bin that is 24280000 supported by the printer but is disabled. This bin is an 24290000 inserter bin. The MMC structured field is contained in a 24300000 medium map in the form 24310000 definition. The output statement is in the JCL. 24320000 24330000 SYSTEM ACTION: PSF continues processing, selecting paper from 24340000 an alternative bin that is not an inserter bin. 24350000 24360000 USER RESPONSE: If the output is not acceptable, submit the 24370000 print request to a printer that has the specified bin available, 24380000 or ensure that the bin is enabled on the original printer before 24390000 resubmitting the print request. 24400000 24410000 SYSTEM PROGRAMMER RESPONSE: No response is necessary. 24420000 24430000 OPERATOR RESPONSE: No response is necessary. 24440000 24450000 PROBLEM DETERMINATION: None. 24460000 24470000 ********************************************************** 24480000 24490000 APS631I A STAPLE JAM HAS OCCURRED WHILE ACCUMULATING 24500000 SHEETS FOR A FINISHING OPERATION. PARTIAL OR DUPLICATE 24510000 PAGES MAY BE PRINTED. 24520000 24530000 Explanation: The staple mechanism on a printer or post 24540000 processor has jammed or has caused a physical-media jam. 24550000 The printer detected and reported an asynchronous 24560000 intervention-required error with an action code of X'0A' 24570000 (sense byte 2). For more information about this error, 24580000 refer to the printer publications for the printer that 24590000 reported this error. 24600000 24610000 System Action: PSF retransmits pages to the printer 24620000 starting from the Jam Recovery Printer Counter. Pages 24630000 may be duplicated during recovery. If repositioning is 24640000 not supported in the current environment, the data 24650000 set is terminated. 24660000 24670000 User Response: The printed output may be acceptable. 24680000 If any pages were duplicated, you may want to 24690000 resubmit the print request. If the error condition 24700000 persists, consult your system programmer. 24710000 24720000 System Programmer Response: If the error condition persists, 24730000 follow the procedures described in Print Services Facility/MVS: 24740000 Diagnosis Guide and Reference before contacting the IBM 24750000 Support Center. 24760000 24770000 Operator Response: Refer to the operator's guide for the 24780000 printer that reported this error and clear the paper from 24790000 the printer and post processor. PSF assumes that pages 24800000 between the Jam Recovery Printer Counter and the Stacked 24810000 Printer Counter are not damaged and do not need to be reprinted. 24820000 If any pages between these two printer counters do need to 24830000 be reprinted, use the Job Entry Subsystem (JES) BACKSPACE 24840000 command. 24850000 24860000 Problem Determination: Items 1, 8, 18 24870000 24880000 ********************************************************** 24890000 24900000 APS632I DATA IN A FORMDEF RESOURCE IS INCOMPATIBLE WITH 24910000 THE PRINT REQUEST: THE OUTPUT CONTAINS 24920000 TOO MANY SHEETS TO PERFORM THE 24930000 FINISHING OPERATION SPECIFIED IN THE MEDIUM 24940000 FINISHING CONTROL STRUCTURED FIELD. 24950000 24960000 Explanation: A finishing operation was requested for a 24970000 collection of sheets, but the number of sheets was too 24980000 large for the operation. 24990000 25000000 Finishing operation triplets are specified in the Medium 25010000 Finishing Control (MFC) structured field. 25020000 The MFC is specified in the Document Environment Group of 25030000 the form definition. 25040000 25050000 System Action: PSF stops printing and processing the data set. 25060000 The finishing operation is not applied or incompletely applied. 25070000 25080000 User Response: If the output is not acceptable: 25090000 25100000 -Verify that you have requested the appropriate form definition 25110000 for the finishing operation intended 25120000 25130000 -submit the print request to a printer that can perform 25140000 the finishing operation 25150000 25160000 -if errors caused message pages to be added to the output 25170000 or pages to be skipped fix those errors so that the 25180000 correct number of pages is printed 25190000 25200000 System Programmer Response: If an IBM licensed program 25210000 was used to create the structured fields for the MFC 25220000 with the error, verify that the input to that program was 25230000 valid. If the input was valid, refer to Advanced 25240000 Function Printing: Diagnosis Guide and Print Services 25250000 Facility/MVS: Diagnosis Guide and Reference for 25260000 assistance in determining the source of the problem. If 25270000 the error involves separator pages or the message data 25280000 set, use the information provided in the User Response 25290000 section to correct the error. 25300000 25310000 Operator Response: If this message displays on the 25320000 operator's console, it indicates that the resource 25330000 containing the error is defined for a separator page, 25340000 for the message data set, or as the default resource for 25350000 user print data sets in the PSF startup procedure. Inform 25360000 your system programmer. 25370000 25380000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 25390000 25400000 ********************************************************** 25410000 25420000 APS633I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 25430000 OR UNSUPPORTED: THE MEDIUM 25440000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 25450000 INVALID OR UNSUPPORTED FINISHING OPERATION TYPE 25460000 FOR THE SELECTED MEDIA. 25470000 25480000 Explanation: The operation type field (byte 2) in a 25490000 finishing operation triplet (X'85') contains an invalid 25500000 or unsupported value for the selected media. 25510000 25520000 Finishing operation triplets are specified in the Medium 25530000 Finishing Control (MFC) structured field. 25540000 The MFC is specified in the Document Environment Group of 25550000 the form definition or in a Medium Map. 25560000 25570000 System Action: PSF continues processing the data set. 25580000 The finishing operation is not applied or incompletely applied. 25590000 25600000 User Response: If the output is not acceptable: 25610000 25620000 -verify that you have requested the appropriate form definition 25630000 for the finishing operation intended 25640000 25650000 -verify that the selected media is the type intended for 25660000 the finishing operation. If the wrong media was selected 25670000 either select a different input bin or have the correct 25680000 media loaded in this input bin. 25690000 25700000 -submit the print request to a printer that can perform 25710000 the finishing operation 25720000 25730000 -If you created the structured fields for 25740000 the form definition, correct the structured field 25750000 and resubmit the print request. Refer to Mixed Object 25760000 Document Content Architecture Reference 25770000 for more information about the structured field. 25780000 If the structured field has no error, 25790000 the error may be a printer configuration 25800000 problem or a printer logic error. If you 25810000 used a program to create the structured fields for 25820000 the form definition, contact your system programmer. 25830000 25840000 System Programmer Response: If an IBM licensed program 25850000 was used to create the structured fields for the MFC 25860000 with the error, verify that the input to that program was 25870000 valid. If the input was valid, refer to Advanced 25880000 Function Printing: Diagnosis Guide and Print Services 25890000 Facility/MVS: Diagnosis Guide and Reference for 25900000 assistance in determining the source of the problem. If 25910000 the error involves separator pages or the message data 25920000 set, use the information provided in the User Response 25930000 section to correct the error. 25940000 25950000 Operator Response: If this message displays on the 25960000 operator's console, it indicates that the resource 25970000 containing the error is defined for a separator page, 25980000 for the message data set, or as the default resource for 25990000 user print data sets in the PSF startup procedure. Inform 26000000 your system programmer. 26010000 26020000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 26030000 26040000 ********************************************************** 26050000 26060000 APS634I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 26070000 OR UNSUPPORTED: THE MEDIUM 26080000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 26090000 INVALID OR UNSUPPORTED FINISHING OPERATION 26100000 REFERENCE CORNER AND EDGE FOR THE MEDIA BEING 26110000 FINISHED. 26120000 26130000 Explanation: The reference corner and edge field (byte 5) 26140000 in a finishing operation triplet (X'85') contains an 26150000 invalid or unsupported value for the media being finished. 26160000 This can be caused when a supported media size has different 26170000 supported reference corners and edges depending on which 26180000 edge of the media is the leading edge. 26190000 26200000 Finishing operation triplets are specified in the Medium 26210000 Finishing Control (MFC) structured field. 26220000 The MFC is specified in the Document Environment Group of 26230000 the form definition or in a Medium Map. 26240000 26250000 System Action: PSF continues processing the data set. 26260000 The finishing operation is not applied or incompletely applied. 26270000 26280000 User Response: If the output is not acceptable: 26290000 26300000 -verify that you have requested the appropriate form definition 26310000 for the finishing operation intended 26320000 26330000 -ensure that the media is oriented properly in the the 26340000 input bin for the requested finishing operation. 26350000 26360000 -submit the print request to a printer that can perform 26370000 the finishing operation 26380000 26390000 -If you created the structured fields for 26400000 the form definition, correct the structured field 26410000 and resubmit the print request. Refer to Mixed Object 26420000 Document Content Architecture Reference 26430000 for more information about the structured field. 26440000 If the structured field has no error, 26450000 the error may be a printer configuration 26460000 problem or a printer logic error. If you 26470000 used a program to create the structured fields for 26480000 the form definition, contact your system programmer. 26490000 26500000 System Programmer Response: If an IBM licensed program 26510000 was used to create the structured fields for the MFC 26520000 with the error, verify that the input to that program was 26530000 valid. If the input was valid, refer to Advanced 26540000 Function Printing: Diagnosis Guide and Print Services 26550000 Facility/MVS: Diagnosis Guide and Reference for 26560000 assistance in determining the source of the problem. If 26570000 the error involves separator pages or the message data 26580000 set, use the information provided in the User Response 26590000 section to correct the error. 26600000 26610000 Operator Response: If this message displays on the 26620000 operator's console, it indicates that the resource 26630000 containing the error is defined for a separator page, 26640000 for the message data set, or as the default resource for 26650000 user print data sets in the PSF startup procedure. Inform 26660000 your system programmer. 26670000 26680000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 26690000 26700000 ********************************************************** 26710000 26720000 APS641I A MECHANISM EXCEPTION OCCURRED THAT PREVENTS 26730000 A FINISHING OPERATION FROM BEING APPLIED. 26740000 26750000 Explanation: The finishing mechanism on a printer or post 26760000 processor has an intervention required condition. 26770000 The printer detected and reported an asynchronous 26780000 intervention-required error with an action code of X'0A' 26790000 (sense byte 2). For more information about this error, 26800000 refer to the printer publications for the printer that 26810000 reported this error. 26820000 26830000 System Action: PSF retransmits pages to the printer 26840000 starting from the Jam Recovery Printer Counter. Pages 26850000 may be duplicated during recovery. If repositioning is 26860000 not supported in the current environment, the data 26870000 set is terminated. 26880000 26890000 User Response: The printed output may be acceptable. 26900000 If any pages were duplicated, you may want to 26910000 resubmit the print request. If the error condition 26920000 persists, consult your system programmer. 26930000 26940000 System Programmer Response: If the error condition persists, 26950000 follow the procedures described in Print Services Facility/MVS: 26960000 Diagnosis Guide and Reference before contacting the IBM 26970000 Support Center. 26980000 26990000 Operator Response: Refer to the operator's guide for the 27000000 printer that reported this error and clear the paper from 27010000 the printer and post processor. PSF assumes that pages 27020000 between the Jam Recovery Printer Counter and the Stacked 27030000 Printer Counter are not damaged and do not need to be reprinted. 27040000 If any pages between these two printer counters do need to 27050000 be reprinted, use the Job Entry Subsystem (JES) BACKSPACE 27060000 command. 27070000 27080000 Problem Determination: Items 1, 8, 18 27090000 27100000 ********************************************************** 27110000 27120000 APS642I THE MEDIUM FINISHING CONTROL (MFC) STRUCTURED 27130000 FIELD IN THE DOCUMENT ENVIRONMENT GROUP SPECIFIES 27140000 FINISHING OPERATION TRIPLETS THAT ARE 27150000 INCOMPATIBLE WITH THE FINISHING OPERATION TRIPLETS 27160000 SPECIFIED ON THE MFC STRUCTURED FIELD IN A MEDIUM 27170000 MAP. 27180000 27190000 Explanation: The Medium Finishing Control (MFC) structured 27200000 field is specified in both the Document Environment Group 27210000 and in the Medium Map and contain 27220000 finishing operation triplets that are 27230000 incompatible. Compatible combinations of finishing 27240000 operations are specific to a particular presentation 27250000 device. 27260000 27270000 The MFC is specified in the Document Environment Group of 27280000 the form definition or in a Medium Map. 27290000 27300000 System Action: PSF continues processing the data set. 27310000 The finishing operation is not applied or incompletely applied. 27320000 27330000 User Response: If the output is not acceptable: 27340000 27350000 - Verify that you have requested the appropriate form definition 27360000 for the finishing operation intended 27370000 27380000 - submit the print request to a printer that can perform 27390000 the finishing operation 27400000 27410000 - If you created the structured fields for 27420000 the form definition, correct the error 27430000 and resubmit the print request. Refer to Mixed Object 27440000 Document Content Architecture Reference 27450000 for more information about the structured field. 27460000 If the MFC contains no triplets or no triplets that might 27470000 be incompatible, the error may be a printer configuration 27480000 problem or a printer logic error. 27490000 If you used a program to create the structured fields for 27500000 the form definition, contact your system programmer. 27510000 27520000 System Programmer Response: If an IBM licensed program 27530000 was used to create the structured fields for the MFC 27540000 with the error, verify that the input to that program was 27550000 valid. If the input was valid, refer to Advanced 27560000 Function Printing: Diagnosis Guide and Print Services 27570000 Facility/MVS: Diagnosis Guide and Reference for 27580000 assistance in determining the source of the problem. If 27590000 the error involves separator pages or the message data 27600000 set, use the information provided in the User Response 27610000 section to correct the error. 27620000 27630000 Operator Response: If this message displays on the 27640000 operator's console, it indicates that the resource 27650000 containing the error is defined for a separator page, 27660000 for the message data set, or as the default resource for 27670000 user print data sets in the PSF startup procedure. Inform 27680000 your system programmer. 27690000 27700000 Problem Determination: Items 1,2,13,15c,17,19 27710000 27720000 ********************************************************** 27730000 27740000 APS643I DATA IN A FORMDEF RESOURCE IS INCOMPATIBLE WITH 27750000 THE PRINT REQUEST: THE OUTPUT CONTAINS 27760000 TOO MANY SHEETS TO PERFORM THE 27770000 FINISHING OPERATION SPECIFIED IN THE MEDIUM 27780000 FINISHING CONTROL STRUCTURED FIELD. 27790000 27800000 Explanation: A finishing operation was requested for a 27810000 collection of sheets, but the number of sheets was too 27820000 large for the operation. 27830000 27840000 Finishing operation triplets are specified in the Medium 27850000 Finishing Control (MFC) structured field. 27860000 The MFC is specified in the Document Environment Group of 27870000 the form definition. 27880000 27890000 System Action: PSF stops printing and processing the data set. 27900000 The finishing operation is not applied or incompletely applied. 27910000 27920000 User Response: If the output is not acceptable: 27930000 27940000 - Verify that you have requested the appropriate form definition 27950000 for the finishing operation intended 27960000 27970000 -submit the print request to a printer that can perform 27980000 the finishing operation 27990000 28000000 -if errors caused message pages to be added to the output 28010000 fix those errors so that the 28020000 correct number of pages is printed 28030000 28040000 System Programmer Response: If an IBM licensed program 28050000 was used to create the structured fields for the MFC 28060000 with the error, verify that the input to that program was 28070000 valid. If the input was valid, refer to Advanced 28080000 Function Printing: Diagnosis Guide and Print Services 28090000 Facility/MVS: Diagnosis Guide and Reference for 28100000 assistance in determining the source of the problem. If 28110000 the error involves separator pages or the message data 28120000 set, use the information provided in the User Response 28130000 section to correct the error. 28140000 28150000 Operator Response: If this message displays on the 28160000 operator's console, it indicates that the resource 28170000 containing the error is defined for a separator page, 28180000 for the message data set, or as the default resource for 28190000 user print data sets in the PSF startup procedure. Inform 28200000 your system programmer. 28210000 28220000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 28230000 28240000 ********************************************************** 28250000 28260000 APS644I MIXED SIZES OF PHYSICAL MEDIA WERE SELECTED TO 28270000 BE FINISHED BUT THE PRINTER DOES NOT SUPPORT 28280000 FINISHING ON A GROUP OF SHEETS OF DIFFERENT SIZES. 28290000 28300000 Explanation: A finishing operation was requested for a 28310000 collection of sheets of mixed sizes, but the device requires 28320000 all of the sheets in the collection to be the same size. 28330000 28340000 Finishing operation triplets are specified in the Medium 28350000 Finishing Control (MFC) structured field. 28360000 The MFC is specified in the Document Environment Group of 28370000 the form definition or in a Medium Map. 28380000 28390000 System Action: PSF stops printing and processing the data set. 28400000 The finishing operation is not applied or incompletely applied. 28410000 28420000 User Response: If the output is not acceptable: 28430000 28440000 -if you have selected multiple input bins for a collection 28450000 of sheets to be finished make sure the media size in 28460000 each is the same. 28470000 28480000 -verify that you have requested the appropriate form definition 28490000 for the finishing operation intended 28500000 28510000 -submit the print request to a printer that can perform 28520000 the finishing operation 28530000 28540000 -If you created the structured fields for 28550000 the form definition, correct the structured field 28560000 and resubmit the print request. Refer to Mixed Object 28570000 Document Content Architecture Reference 28580000 for more information about the structured field. 28590000 If the structured field has no error, 28600000 the error may be a printer configuration 28610000 problem or a printer logic error. If you 28620000 used a program to create the structured fields for 28630000 the form definition, contact your system programmer. 28640000 28650000 System Programmer Response: If an IBM licensed program 28660000 was used to create the structured fields for the MFC 28670000 with the error, verify that the input to that program was 28680000 valid. If the input was valid, refer to Advanced 28690000 Function Printing: Diagnosis Guide and Print Services 28700000 Facility/MVS: Diagnosis Guide and Reference for 28710000 assistance in determining the source of the problem. If 28720000 the error involves separator pages or the message data 28730000 set, use the information provided in the User Response 28740000 section to correct the error. 28750000 28760000 Operator Response: If this message displays on the 28770000 operator's console, it indicates that the resource 28780000 containing the error is defined for a separator page, 28790000 for the message data set, or as the default resource for 28800000 user print data sets in the PSF startup procedure. Inform 28810000 your system programmer. 28820000 28830000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 28840000 28850000 ********************************************************** 28860000 28870000 APS706I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 28880000 OR UNSUPPORTED: THE MEDIUM 28890000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 28900000 INVALID OR UNSUPPORTED FINISHING OPERATION 28910000 REFERENCE CORNER AND EDGE FOR THIS FINISHER. 28920000 28930000 Explanation: The reference corner and edge field (byte 5) 28940000 in a finishing operation triplet (X'85') contains an 28950000 invalid or unsupported value for this finisher. 28960000 28970000 Finishing operation triplets are specified in the Medium 28980000 Finishing Control (MFC) structured field. 28990000 The MFC is specified in the Document Environment Group of 29000000 the form definition or in a Medium Map. 29010000 29020000 System Action: PSF continues processing the data set. 29030000 The finishing operation is not applied or incompletely applied. 29040000 29050000 User Response: If the output is not acceptable: 29060000 29070000 -verify that you have requested the appropriate form definition 29080000 for the finishing operation intended 29090000 29100000 -submit the print request to a printer that can perform 29110000 the finishing operation 29120000 29130000 -If you created the structured fields for 29140000 the form definition, correct the structured field 29150000 and resubmit the print request. Refer to Mixed Object 29160000 Document Content Architecture Reference 29170000 for more information about the structured field. 29180000 If the structured field has no error, 29190000 the error may be a printer configuration 29200000 problem or a printer logic error. If you 29210000 used a program to create the structured fields for 29220000 the form definition, contact your system programmer. 29230000 29240000 System Programmer Response: If an IBM licensed program 29250000 was used to create the structured fields for the MFC 29260000 with the error, verify that the input to that program was 29270000 valid. If the input was valid, refer to Advanced 29280000 Function Printing: Diagnosis Guide and Print Services 29290000 Facility/MVS: Diagnosis Guide and Reference for 29300000 assistance in determining the source of the problem. If 29310000 the error involves separator pages or the message data 29320000 set, use the information provided in the User Response 29330000 section to correct the error. 29340000 29350000 Operator Response: If this message displays on the 29360000 operator's console, it indicates that the resource 29370000 containing the error is defined for a separator page, 29380000 for the message data set, or as the default resource for 29390000 user print data sets in the PSF startup procedure. Inform 29400000 your system programmer. 29410000 29420000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 29430000 29440000 ********************************************************** 29450000 29460000 APS735I SELECTED PHYSICAL MEDIA TO BE FINISHED CANNOT 29470000 BE SENT TO THE SELECTED MEDIA DESTINATION. 29480000 29490000 Explanation: The physical media cannot be sent to the 29500000 selected media destination. The printer cannot continue 29510000 processing the data set. 29520000 29530000 System Action: PSF stops processing and printing the data set. 29540000 29550000 User Response: 29560000 29570000 -ensure that the input media source is valid 29580000 and that it contains the appropriate media for the finishing 29590000 operation being performed. 29600000 29610000 The input media source can be selected in the form definition 29620000 or the default input media source for the printer is used. 29630000 29640000 -ensure that the output media destination is valid for the 29650000 finishing operation being performed. 29660000 29670000 The media destination can be selected on the JCL OUTPUT statement 29680000 with the OUTBIN keyword or the default media destination was 29690000 used. 29700000 29710000 -verify that you have requested the appropriate form definition 29720000 for the finishing operation intended 29730000 29740000 System Programmer Response: No response is necessary. 29750000 29760000 Operator Response: No response is necessary. 29770000 29780000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 29790000 29800000 29810000 ********************************************************** 29820000 29830000 APS736I PARAMETERS IN A FORMDEF RESOURCE ARE 29840000 INCOMPATIBLE: THE MEDIUM 29850000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES 29860000 INCOMPATIBLE FINISHING OPERATION TRIPLETS. 29870000 29880000 Explanation: The Medium Finishing Control (MFC) structured 29890000 field contains finishing operation triplets that are 29900000 incompatible. Compatible combinations of finishing 29910000 operations are specific to a particular presentation 29920000 device. 29930000 29940000 The MFC is specified in the Document Environment Group of 29950000 the form definition or in a Medium Map. 29960000 29970000 System Action: PSF continues processing the data set. 29980000 The finishing operation is not applied or incompletely applied. 29990000 30000000 User Response: If the output is not acceptable: 30010000 30020000 - Verify that you have requested the appropriate form definition 30030000 for the finishing operation intended 30040000 30050000 - submit the print request to a printer that can perform 30060000 the finishing operation 30070000 30080000 - If you created the structured fields for 30090000 the form definition, correct the error 30100000 and resubmit the print request. Refer to Mixed Object 30110000 Document Content Architecture Reference 30120000 for more information about the structured field. 30130000 If the MFC contains no triplets or no triplets that might 30140000 be incompatible, the error may be a printer configuration 30150000 problem or a printer logic error. 30160000 If you used a program to create the structured fields for 30170000 the form definition, contact your system programmer. 30180000 30190000 System Programmer Response: If an IBM licensed program 30200000 was used to create the structured fields for the MFC 30210000 with the error, verify that the input to that program was 30220000 valid. If the input was valid, refer to Advanced 30230000 Function Printing: Diagnosis Guide and Print Services 30240000 Facility/MVS: Diagnosis Guide and Reference for 30250000 assistance in determining the source of the problem. If 30260000 the error involves separator pages or the message data 30270000 set, use the information provided in the User Response 30280000 section to correct the error. 30290000 30300000 Operator Response: If this message displays on the 30310000 operator's console, it indicates that the resource 30320000 containing the error is defined for a separator page, 30330000 for the message data set, or as the default resource for 30340000 user print data sets in the PSF startup procedure. Inform 30350000 your system programmer. 30360000 30370000 Problem Determination: Items 1,2,13,15c,17,19 30380000 30390000 ********************************************************** 30400000 30410000 APS775I DATA IN A FORMDEF RESOURCE IS INCOMPATIBLE WITH 30420000 THE PRINT REQUEST: THE OUTPUT CONTAINS 30430000 TOO MANY OR TOO FEW SHEETS TO PERFORM THE 30440000 FINISHING OPERATION SPECIFIED IN THE MEDIUM 30450000 FINISHING CONTROL STRUCTURED FIELD. 30460000 30470000 Explanation: A finishing operation was requested for a 30480000 collection of sheets, but the number of sheets was too 30490000 large or too small for the operation. 30500000 30510000 Finishing operation triplets are specified in the Medium 30520000 Finishing Control (MFC) structured field. 30530000 The MFC is specified in the Document Environment Group of 30540000 the form definition. 30550000 30560000 System Action: PSF continues processing the data set. 30570000 The finishing operation is not applied or incompletely applied. 30580000 30590000 User Response: If the output is not acceptable: 30600000 30610000 - Verify that you have requested the appropriate form definition 30620000 for the finishing operation intended 30630000 30640000 -submit the print request to a printer that can perform 30650000 the finishing operation 30660000 30670000 -if errors caused message pages to be added to the output 30680000 or pages to be skipped fix those errors so that the 30690000 correct number of pages is printed 30700000 30710000 System Programmer Response: If an IBM licensed program 30720000 was used to create the structured fields for the MFC 30730000 with the error, verify that the input to that program was 30740000 valid. If the input was valid, refer to Advanced 30750000 Function Printing: Diagnosis Guide and Print Services 30760000 Facility/MVS: Diagnosis Guide and Reference for 30770000 assistance in determining the source of the problem. If 30780000 the error involves separator pages or the message data 30790000 set, use the information provided in the User Response 30800000 section to correct the error. 30810000 30820000 Operator Response: If this message displays on the 30830000 operator's console, it indicates that the resource 30840000 containing the error is defined for a separator page, 30850000 for the message data set, or as the default resource for 30860000 user print data sets in the PSF startup procedure. Inform 30870000 your system programmer. 30880000 30890000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 30900000 30910000 ********************************************************** 30920000 30930000 APS776I THE POST PROCESSOR HAS DETECTED A CONDITION THAT 30940000 CAUSES PAGES TO BE DISCARDED. 30950000 30960000 Explanation: Paper in the post processor was discarded. 30970000 The printer detected and reported an asynchronous 30980000 intervention-required error with an action code of X'0A' 30990000 (sense byte 2). For more information about this error, 31000000 refer to the printer publications for the printer that 31010000 reported this error. 31020000 31030000 System Action: PSF retransmits pages to the printer 31040000 starting from the Jam Recovery Printer Counter. Pages 31050000 may be duplicated during recovery. If repositioning is 31060000 not supported in the current environment, the data 31070000 set is terminated. 31080000 31090000 User Response: The printed output may be acceptable. 31100000 If any pages were duplicated, you may want to 31110000 resubmit the print request. If the error condition 31120000 persists, consult your system programmer. 31130000 31140000 System Programmer Response: If the error condition persists, 31150000 follow the procedures described in Print Services Facility/MVS: 31160000 Diagnosis Guide and Reference before contacting the IBM 31170000 Support Center. 31180000 31190000 Operator Response: Refer to the operator's guide for the 31200000 printer that reported this error and clear the paper from 31210000 the printer and post processor. PSF assumes that pages 31220000 between the Jam Recovery Printer Counter and the Stacked 31230000 Printer Counter are not damaged and do not need to be reprinted. 31240000 If any pages between these two printer counters do need to 31250000 be reprinted, use the Job Entry Subsystem (JES) BACKSPACE 31260000 command. 31270000 31280000 Problem Determination: Items 1, 8, 18 31290000 31300000 ********************************************************** 31310000 31320000 31330000 APS820I A PARAMETER VALUE IN A FORMDEF RESOURCE IS 31340000 UNSUPPORTED: THE MEDIUM 31350000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 31360000 UNSUPPORTED FINISHING OPERATION COUNT VALUE. 31370000 31380000 Explanation: The finishing operation count field (byte 6) 31390000 in a finishing operation triplet (X'85') contains an 31400000 unsupported value. 31410000 31420000 Finishing operation triplets are specified in the Medium 31430000 Finishing Control (MFC) structured field. 31440000 The MFC is specified in the Document Environment Group of 31450000 the form definition. 31460000 31470000 System Action: PSF continues processing the data set. 31480000 The finishing operation is not applied or incompletely applied. 31490000 31500000 User Response: If the output is not acceptable: 31510000 31520000 -verify that you have requested the appropriate form definition 31530000 for the finishing operation intended 31540000 31550000 -submit the print request to a printer that can perform 31560000 the finishing operation 31570000 31580000 -If you created the structured fields for 31590000 the form definition, correct the structured field 31600000 and resubmit the print request. Refer to Mixed Object 31610000 Document Content Architecture Reference 31620000 for more information about the structured field. 31630000 If the structured field has no error, 31640000 the error may be a printer configuration 31650000 problem or a printer logic error. If you 31660000 used a program to create the structured fields for 31670000 the form definition, contact your system programmer. 31680000 31690000 System Programmer Response: If an IBM licensed program 31700000 was used to create the structured fields for the MFC 31710000 with the error, verify that the input to that program was 31720000 valid. If the input was valid, refer to Advanced 31730000 Function Printing: Diagnosis Guide and Print Services 31740000 Facility/MVS: Diagnosis Guide and Reference for 31750000 assistance in determining the source of the problem. If 31760000 the error involves separator pages or the message data 31770000 set, use the information provided in the User Response 31780000 section to correct the error. 31790000 31800000 Operator Response: If this message displays on the 31810000 operator's console, it indicates that the resource 31820000 containing the error is defined for a separator page, 31830000 for the message data set, or as the default resource for 31840000 user print data sets in the PSF startup procedure. Inform 31850000 your system programmer. 31860000 31870000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 31880000 31890000 ********************************************************** 31900000 31910000 APS829I A PAPER JAM HAS OCCURRED WHILE ACCUMULATING 31920000 SHEETS FOR A FINISHING OPERATION. PARTIAL OR DUPLICATE 31930000 PAGES MAY BE PRINTED. 31940000 31950000 Explanation: Paper in the post processor was discarded. 31960000 The printer detected and reported an asynchronous 31970000 intervention-required error with an action code of X'0A' 31980000 (sense byte 2). For more information about this error, 31990000 refer to the printer publications for the printer that 32000000 reported this error. 32010000 32020000 System Action: PSF retransmits pages to the printer 32030000 starting from the Jam Recovery Printer Counter. Pages 32040000 may be duplicated during recovery. If repositioning is 32050000 not supported in the current environment, the data 32060000 set is terminated. 32070000 32080000 User Response: The printed output may be acceptable. 32090000 If any pages were duplicated, you may want to 32100000 resubmit the print request. If the error condition 32110000 persists, consult your system programmer. 32120000 32130000 System Programmer Response: If the error condition persists, 32140000 follow the procedures described in Print Services Facility/MVS: 32150000 Diagnosis Guide and Reference before contacting the IBM 32160000 Support Center. 32170000 32180000 Operator Response: Refer to the operator's guide for the 32190000 printer that reported this error and clear the paper from 32200000 the printer and post processor. PSF assumes that pages 32210000 between the Jam Recovery Printer Counter and the Stacked 32220000 Printer Counter are not damaged and do not need to be reprinted. 32230000 If any pages between these two printer counters do need to 32240000 be reprinted, use the Job Entry Subsystem (JES) BACKSPACE 32250000 command. 32260000 32270000 Problem Determination: Items 1, 8, 18 32280000 32290000 32300000 ********************************************************** 32310000 32320000 APS839I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 32330000 OR UNSUPPORTED: THE MEDIUM 32340000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 32350000 INVALID OR UNSUPPORTED FINISHING OPERATION AXIS 32360000 OFFSET VALUE. 32370000 32380000 Explanation: The axis offset field (bytes 7-8) in a 32390000 finishing operation triplet (X'85') contains an 32400000 invalid or unsupported value. 32410000 32420000 Finishing operation triplets are specified in the Medium 32430000 Finishing Control (MFC) structured field. 32440000 The MFC is specified in the Document Environment Group of 32450000 the form definition. 32460000 32470000 System Action: PSF continues processing the data set. 32480000 The finishing operation is not applied or incompletely applied. 32490000 32500000 User Response: If the output is not acceptable: 32510000 32520000 -verify that you have requested the appropriate form definition 32530000 for the finishing operation intended 32540000 32550000 -submit the print request to a printer that can perform 32560000 the finishing operation 32570000 32580000 -If you created the structured fields for 32590000 the form definition, correct the structured field 32600000 and resubmit the print request. Refer to Mixed Object 32610000 Document Content Architecture Reference 32620000 for more information about the structured field. 32630000 If the structured field has no error, 32640000 the error may be a printer configuration 32650000 problem or a printer logic error. If you 32660000 used a program to create the structured fields for 32670000 the form definition, contact your system programmer. 32680000 32690000 System Programmer Response: If an IBM licensed program 32700000 was used to create the structured fields for the MFC 32710000 with the error, verify that the input to that program was 32720000 valid. If the input was valid, refer to Advanced 32730000 Function Printing: Diagnosis Guide and Print Services 32740000 Facility/MVS: Diagnosis Guide and Reference for 32750000 assistance in determining the source of the problem. If 32760000 the error involves separator pages or the message data 32770000 set, use the information provided in the User Response 32780000 section to correct the error. 32790000 32800000 Operator Response: If this message displays on the 32810000 operator's console, it indicates that the resource 32820000 containing the error is defined for a separator page, 32830000 for the message data set, or as the default resource for 32840000 user print data sets in the PSF startup procedure. Inform 32850000 your system programmer. 32860000 32870000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 32880000 32890000 ********************************************************** 32900000 32910000 APS860I THE SPECIFIED INPUT BIN CANNOT BE USED WITH THE 32920000 SPECIFIED OUTPUT BIN. 32930000 32940000 Explanation: The specified media source cannot be used 32950000 with the specified media destination. One example of this 32960000 is using inserts that are located on a post processor 32970000 input bin and routing the data set to an output bin located 32980000 back on the printer. 32990000 33000000 System Action: PSF will release the current data set back 33010000 to JES and will request that it be held by the system unless 33020000 PRTERR=QUIT was specified on the OUTPUT statement. 33030000 33040000 User Response: If you specified an output bin with the 33050000 OUTBIN keyword, and it is the wrong output bin change 33060000 the bin and resubmit the the print job. Your data set may 33070000 require a different printer configuration. For more 33080000 information about your printer configuration refer to the 33090000 printer publications for the printer that reported this 33100000 error. 33110000 33120000 System Programmer Response: No response is necessary. 33130000 33140000 Operator Response: No response is necessary. 33150000 33160000 Problem Determination: Items 1,2,17,27 33170000 33180000 ********************************************************** 33190000 33200000 APS863I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 33210000 OR UNSUPPORTED: THE MEDIUM 33220000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 33230000 INVALID OR UNSUPPORTED FINISHING OPERATION TYPE 33240000 FOR THIS FINISHER. 33250000 33260000 Explanation: The operation type field (byte 2) in a 33270000 finishing operation triplet (X'85') contains an invalid 33280000 or unsupported value for this finisher. 33290000 33300000 Finishing operation triplets are specified in the Medium 33310000 Finishing Control (MFC) structured field. 33320000 The MFC is specified in the Document Environment Group of 33330000 the form definition or in a Medium Map. 33340000 33350000 System Action: PSF continues processing the data set. 33360000 The finishing operation is not applied or incompletely applied. 33370000 33380000 User Response: If the output is not acceptable: 33390000 33400000 -verify that you have requested the appropriate form definition 33410000 for the finishing operation intended 33420000 33430000 -submit the print request to a printer that can perform 33440000 the finishing operation 33450000 33460000 -If you created the structured fields for 33470000 the form definition, correct the structured field 33480000 and resubmit the print request. Refer to Mixed Object 33490000 Document Content Architecture Reference 33500000 for more information about the structured field. 33510000 If the structured field has no error, 33520000 the error may be a printer configuration 33530000 problem or a printer logic error. If you 33540000 used a program to create the structured fields for 33550000 the form definition, contact your system programmer. 33560000 33570000 System Programmer Response: If an IBM licensed program 33580000 was used to create the structured fields for the MFC 33590000 with the error, verify that the input to that program was 33600000 valid. If the input was valid, refer to Advanced 33610000 Function Printing: Diagnosis Guide and Print Services 33620000 Facility/MVS: Diagnosis Guide and Reference for 33630000 assistance in determining the source of the problem. If 33640000 the error involves separator pages or the message data 33650000 set, use the information provided in the User Response 33660000 section to correct the error. 33670000 33680000 Operator Response: If this message displays on the 33690000 operator's console, it indicates that the resource 33700000 containing the error is defined for a separator page, 33710000 for the message data set, or as the default resource for 33720000 user print data sets in the PSF startup procedure. Inform 33730000 your system programmer. 33740000 33750000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 33760000 33770000 33780000 ********************************************************** 33790000 33800000 APS875I DATA IN A FORMDEF RESOURCE IS INCOMPATIBLE: 33810000 THE MEDIUM FINISHING CONTROL STRUCTURED FIELD 33820000 SPECIFIES A FINISHING OPERATION THAT IS 33830000 INCOMPATIBLE WITH THE SELECTED MEDIA OR THE 33840000 SELECTED MEDIA DESTINATION. 33850000 33860000 Explanation: A finishing operation specified in a 33870000 finishing operation triplet (X'85') is incompatible with 33880000 the selected physical media or with the media destination. 33890000 Some printers don't support all sizes of media or 33900000 mixed-size media when finishing. Also some printers restrict 33910000 the possible media destinations of finished data sets to a 33920000 subset of all media destinations available. 33930000 33940000 Finishing operation triplets are specified in the Medium 33950000 Finishing Control (MFC) structured field. 33960000 The MFC is specified in the Document Environment Group of 33970000 the form definition or in a Medium Map. 33980000 33990000 System Action: PSF continues processing the data set. 34000000 The finishing operation is not applied or incompletely applied. 34010000 34020000 User Response: If the output is not acceptable: 34030000 34040000 -if you have specified OUTBIN on your JCL OUTPUT 34050000 statement make sure it selects a media destination 34060000 that supports finished output. 34070000 34080000 -verify that you have requested the appropriate form definition 34090000 for the finishing operation intended 34100000 34110000 -submit the print request to a printer that can perform 34120000 the finishing operation 34130000 34140000 -If you created the structured fields for 34150000 the form definition, correct the structured field 34160000 and resubmit the print request. Refer to Mixed Object 34170000 Document Content Architecture Reference 34180000 for more information about the structured field. 34190000 If the structured field has no error, 34200000 the error may be a printer configuration 34210000 problem or a printer logic error. If you 34220000 used a program to create the structured fields for 34230000 the form definition, contact your system programmer. 34240000 34250000 System Programmer Response: If an IBM licensed program 34260000 was used to create the structured fields for the MFC 34270000 with the error, verify that the input to that program was 34280000 valid. If the input was valid, refer to Advanced 34290000 Function Printing: Diagnosis Guide and Print Services 34300000 Facility/MVS: Diagnosis Guide and Reference for 34310000 assistance in determining the source of the problem. If 34320000 the error involves separator pages or the message data 34330000 set, use the information provided in the User Response 34340000 section to correct the error. 34350000 34360000 Operator Response: If this message displays on the 34370000 operator's console, it indicates that the resource 34380000 containing the error is defined for a separator page, 34390000 for the message data set, or as the default resource for 34400000 user print data sets in the PSF startup procedure. Inform 34410000 your system programmer. 34420000 34430000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 34440000 34450000 ********************************************************** 34460000 34470000 APS885I PARAMETERS IN A FORMDEF RESOURCE ARE INVALID 34480000 OR UNSUPPORTED: THE MEDIUM 34490000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 34500000 INVALID OR UNSUPPORTED NUMBER OF FINISHING 34510000 POSITIONS. 34520000 34530000 Explanation: In a finishing operation triplet (X'85'), 34540000 either the number of position values specified does not 34550000 match the count (byte 6), or the number of supported 34560000 positions has been exceeded. 34570000 34580000 Finishing operation triplets are specified in the Medium 34590000 Finishing Control (MFC) structured field. 34600000 The MFC is specified in the Document Environment Group of 34610000 the form definition. 34620000 34630000 System Action: PSF continues processing the data set. 34640000 The finishing operation is not applied or incompletely applied. 34650000 34660000 User Response: If the output is not acceptable: 34670000 34680000 -verify that you have requested the appropriate form definition 34690000 for the finishing operation intended 34700000 34710000 -submit the print request to a printer that can perform 34720000 the finishing operation 34730000 34740000 -If you created the structured fields for 34750000 the form definition, correct the structured field 34760000 and resubmit the print request. Refer to Mixed Object 34770000 Document Content Architecture Reference 34780000 for more information about the structured field. 34790000 If the structured field has no error, 34800000 the error may be a printer configuration 34810000 problem or a printer logic error. If you 34820000 used a program to create the structured fields for 34830000 the form definition, contact your system programmer. 34840000 34850000 System Programmer Response: If an IBM licensed program 34860000 was used to create the structured fields for the MFC 34870000 with the error, verify that the input to that program was 34880000 valid. If the input was valid, refer to Advanced 34890000 Function Printing: Diagnosis Guide and Print Services 34900000 Facility/MVS: Diagnosis Guide and Reference for 34910000 assistance in determining the source of the problem. If 34920000 the error involves separator pages or the message data 34930000 set, use the information provided in the User Response 34940000 section to correct the error. 34950000 34960000 Operator Response: If this message displays on the 34970000 operator's console, it indicates that the resource 34980000 containing the error is defined for a separator page, 34990000 for the message data set, or as the default resource for 35000000 user print data sets in the PSF startup procedure. Inform 35010000 your system programmer. 35020000 35030000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 35040000 35050000 ********************************************************** 35060000 35070000 APS886I A PARAMETER VALUE IN A FORMDEF RESOURCE IS INVALID 35080000 OR UNSUPPORTED: THE MEDIUM 35090000 FINISHING CONTROL STRUCTURED FIELD SPECIFIES AN 35100000 INVALID OR UNSUPPORTED FINISHING OPERATION 35110000 POSITION VALUE. 35120000 35130000 Explanation: A finishing operation position field 35140000 in a finishing operation triplet (X'85') contains 35150000 an invalid or unsupported value. 35160000 35170000 Finishing operation triplets are specified in the Medium 35180000 Finishing Control (MFC) structured field. 35190000 The MFC is specified in the Document Environment Group of 35200000 the form definition. 35210000 35220000 System Action: PSF continues processing the data set. 35230000 The finishing operation is not applied or incompletely applied. 35240000 35250000 User Response: If the output is not acceptable: 35260000 35270000 -verify that you have requested the appropriate form definition 35280000 for the finishing operation intended 35290000 35300000 -submit the print request to a printer that can perform 35310000 the finishing operation 35320000 35330000 -If you created the structured fields for 35340000 the form definition, correct the structured field 35350000 and resubmit the print request. Refer to Mixed Object 35360000 Document Content Architecture Reference 35370000 for more information about the structured field. 35380000 If the structured field has no error, 35390000 the error may be a printer configuration 35400000 problem or a printer logic error. If you 35410000 used a program to create the structured fields for 35420000 the form definition, contact your system programmer. 35430000 35440000 System Programmer Response: If an IBM licensed program 35450000 was used to create the structured fields for the MFC 35460000 with the error, verify that the input to that program was 35470000 valid. If the input was valid, refer to Advanced 35480000 Function Printing: Diagnosis Guide and Print Services 35490000 Facility/MVS: Diagnosis Guide and Reference for 35500000 assistance in determining the source of the problem. If 35510000 the error involves separator pages or the message data 35520000 set, use the information provided in the User Response 35530000 section to correct the error. 35540000 35550000 Operator Response: If this message displays on the 35560000 operator's console, it indicates that the resource 35570000 containing the error is defined for a separator page, 35580000 for the message data set, or as the default resource for 35590000 user print data sets in the PSF startup procedure. Inform 35600000 your system programmer. 35610000 35620000 Problem Determination: Items 1, 2, 13, 15c, 17, 19 35630000 35640000 ********************************************************** 35650000 35660000 Delete message APS865I. 35670000 35680000 Add the following new abend reason codes to Chapter 2: 35690000 35700000 System Completion Codes and PSF Abend Reason Codes 35710000 35720000 35730000 01BB 35740000 Explanation: 35750000 This abend is issued by module APSPPDCM. 35760000 Not enough storage available for triplet data. 35770000 35780000 System action: 35790000 PSF processing terminates abnormally 35800000 35810000 System programmer response: 35820000 This PSF abend reason code indicates that the REGION size should 35830000 be increased. If the print request is processing in direct-printing 35840000 mode, this REGION size is for the job or step containing the request. 35850000 If the print request is processing in deferred-printing mode, increase 35860000 the REGION parameter used in the PSF startup procedure. 35870000 35880000 ****************************************************************+ 35890000 35900000 0243 35910000 Explanation: This abend is issued by module APSCOPCI -- 35920000 The Printable-Area Self-Defining field was not in the 35930000 XOA Obtain Printer Characteristics acknowledge reply. Thus no 35940000 input bins were defined. 35950000 35960000 System Action: PSF processing terminates abnormally. 35970000 35980000 System Programmer Response: This PSF abend reason code 35990000 indicates a logic error in the microcode of the printer. 36000000 Consult your hardware service representative. This is 36010000 NOT a PSF logic error. 36020000 36030000 ****************************************************************+ 36040000 36050000 0244 36060000 Explanation: This abend is issued by module APSCOPCI -- 36070000 There were no enabled non-inserter input bins defined in the 36080000 Printable-Area Self-Defining field that was returned in the 36090000 XOA Obtain Printer Characteristics acknowledge reply. 36100000 36110000 System Action: PSF processing terminates abnormally. 36120000 36130000 System Programmer Response: This PSF abend reason code indicates 36140000 a configuration error at the printer. A non-inserter input bin 36150000 must be enabled. 36160000 36170000 ****************************************************************+ 36180000 36190000 0629 36200000 Explanation: This abend is issued by APSEATCD-- 36210000 An unrecognized recovery code was found during X'06' 36220000 recovery. 36230000 36240000 System Action: PSF processing terminates abnormally. 36250000 36260000 System Programmer Response: This PSF abend reason code 36270000 indicates a possible logic error. Contact your service 36280000 representative in the IBM Support Center or use your 36290000 electronic link with IBM service for assistance regarding 36300000 this error code. 36310000 36320000 ****************************************************************+ 36330000 36340000 0883 36350000 Explanation: This abend is issued by module APRBPGEX -- 36360000 Not enough storage available for triplet data. 36370000 36380000 System action: PSF processing terminates abnormally 36390000 36400000 System programmer response: 36410000 This PSF abend reason code indicates that the REGION size should 36420000 be increased. If the print request is processing in direct-printing 36430000 mode, this REGION size is for the job or step containing the request. 36440000 If the print request is processing in deferred-printing mode, increase 36450000 the REGION parameter used in the PSF startup procedure. 36460000 36470000 ****************************************************************+ 36480000 08D5 36490000 EXPLANATION: This abend is issued by module APRMSGEX - 36500000 All bins reported back from the printer are either 36510000 disabled or are inserter bins. As a result, there are no bins 36520000 available for printing and the current data set cannot be 36530000 printed. 36540000 36550000 SYSTEM ACTION: PSF processing terminates abnormally. 36560000 36570000 SYSTEM PROGRAMMER RESPONSE: This PSF abend reason code indicates 36580000 a logic error. Contact your service representative in the IBM 36590000 Support Center or use your electronic link with IBM service for 36600000 assistance regarding this error code. 36610000 36620000 36630000 -----------CHANGES FOR OW34806---------------------------------- 36640000 36650000 Add the following new message: 36660000 36670000 APS395I A FORMDEF RESOURCE REQUESTED A MEDIA EJECT CONTROL TO THE 36680000 NEXT BACK-SIDE AND DUPLEX=NO WAS SPECIFIED ON THE OUTPUT 36690000 STATEMENT. 36700000 36710000 Explanation: When a media eject control to the next back-side 36720000 is specified in a formdef, the DUPLEX=NO keyword on the OUTPUT 36730000 statement cannot be used to change from duplex (specified in the 36740000 formdef) to simplex. The reason is that an incompatible request 36750000 is being made - you can't eject to the next back-side when 36760000 simplexing. 36770000 36780000 The only valid options for the duplex keyword when a media eject 36790000 control to the next back-side is specified in the formdef are: 36800000 36810000 If the formdef requests normal or tumble duplex, you may 36820000 specify either duplex=normal or duplex=tumble on the output 36830000 statement. 36840000 36850000 System Action: PSF stops processing the current data set and 36860000 issues additional messages that identify the processing 36870000 environment when the error was found. 36880000 36890000 User Response: Resubmit the job without requesting the duplex 36900000 keyword on the output statement. 36910000 36920000 System Programmer Response: None 36930000 36940000 Operator Response: None 36950000 36960000 Problem Determination: Items 12, 17, 19. 36970000 36980000 -----------CHANGES FOR OW35783---------------------------------- 36990000 37000000 Add the following new message: 37010000 37020000 APS998I THE LAST STATEMENT IN THE MVS DOWNLOAD ROUTING CONTROL 37030000 DATASET WAS NOT PROPERLY TERMINATED. 37040000 37050000 Explanation: MVS Download detected that the last statement in 37060000 the routing-control dataset was not terminated with a semi-colon. 37070000 37080000 System Action: MVS Download ignores the last statement and continues 37090000 processing with the other valid statements. 37100000 37110000 User Response: No response is necessary. 37120000 37130000 System Programmer Response: Correct the invalid statement by 37140000 specifying a terminating semicolon. Ensure all required keywords 37150000 are specified. To use the modified routing-control dataset, 37160000 stop the MVS Download FSS and restart the FSAs. 37170000 37180000 Operator Response: Inform your system programmer that this error 37190000 occurred. 37200000 37210000 Problem Determination: None 37220000 37230000 -----------CHANGES FOR OW35455---------------------------------- 37240000 37250000 1. Page 72 APS292I 37260000 Change "Explanation" section to read as follows: 37270000 37280000 Explanation: Enhanced N_UP is not supported due to one of the 37290000 following : 37300000 o The Page Position (PGP) Format 2 structured field 37310000 requested enhanced N_UP, but N_UP is not supported 37320000 by this printer. 37330000 37340000 o The printer supports enhanced N_UP but was attached 37350000 through Distributed Print Facility (DPF) and enhanced 37360000 N_UP is not supported through DPF. 37370000 37380000 2. Page 72 APS292I 37390000 37400000 Change the first sentence in the "User Response" section to read as 37410000 follows: 37420000 37430000 Resubmit the job to a printer that supports enhanced N_UP (printer 37440000 cannot be attached through DPF); or, if you created the structured 37450000 fields for the form definition, correct the error and resubmit the 37460000 print request. 37470000 37480000 3. Page 72 APS292I 37490000 37500000 Change the "System Programmer Response" to read as follows: 37510000 37520000 If an IBM licensed program was used to create the structured fields 37530000 for the form definition with the error, verify that the input to 37540000 that program was valid. If the input was valid, refer to Advanced 37550000 Function Printing: Diagnosis Guide and Print Services Facility/MVS: 37560000 Diagnosis Guide and Reference for assistance in determining the 37570000 source of the problem. Verify that the printer microcode level 37580000 supports enhanced N_UP printing and is not attached through DPF. 37590000 If the resource containing the error is defined for the separator 37600000 pages or the message data set, or as the default resource for user 37610000 print data sets in the PSF startup procedure, use the information 37620000 provided in the User Response section to correct the error. 37630000 37640000 -----------CHANGES FOR OW36139---------------------------------- 37650000 37660000 1. On page 250 (as modified by apar OW24371) 37670000 add the following new bullet before the "Start 37680000 Session Failed" bullet under APS934I. 37690000 37700000 o Socket Connect Failed -- PSF was not able to establish a 37710000 socket connection with the printer. PSF displays this 37720000 reason when: 37730000 37740000 - The printer might be powered off 37750000 37760000 - If the printer is attached with an i-data 7913 IPDS 37770000 printer LAN Attachment, either the printer or the 37780000 i-data 7913 IPDS Printer LAN Attachment is not 37790000 powered on. 37800000 37810000 - The wrong IP address is specified in the PRINTDEV 37820000 statement. 37830000 37840000 - The printer is not physically attached. 37850000 37860000 - The IP address specified in the PRINTDEV statement is a 37870000 duplicate of another IP address on the network. 37880000 37890000 2. On page 250 (as modified by apar OW24371) 37900000 change the reasons under the "Start Session 37910000 Failed" bulleted item under APS934I to the following and 37920000 also change the title to "Open Session Failed". 37930000 37940000 - The target system is not executing the IBM printer 37950000 layer code. 37960000 37970000 - The printer is being used by another PSF FSA on the same 37980000 host. 37990000 38000000 3. On page 250 (as modified by apar OW24371) 38010000 change the "System Action" for APS934I to read as 38020000 follows. 38030000 38040000 System Action: The PSF FSA ends because the condition cannot be 38050000 retried or the connect interval (CONNINTV) timer has expired. 38060000 38070000 4. On page 251 (as modified by apar OW24371) 38080000 change the bulleted item entitled "Socket 38090000 Connect Failed" under APS935I to read as follows. 38100000 38110000 o Socket Connect Failed -- PSF was not able to establish a 38120000 socket connection with the printer. PSF displays this 38130000 reason when: 38140000 38150000 - The printer might be powered off 38160000 38170000 - If the printer is attached with an i-data 7913 IPDS 38180000 printer LAN Attachment, either the printer or the 38190000 i-data 7913 IPDS Printer LAN Attachment is not 38200000 powered on. 38210000 38220000 - The wrong IP address is specified in the PRINTDEV 38230000 statement. 38240000 38250000 - The printer is not physically attached. 38260000 38270000 - The IP address specified in the PRINTDEV statement is a 38280000 duplicate of another IP address on the network. 38290000 38300000 5. On page 251 (as modified by apar OW24371) 38310000 change the reasons under the "Start Session 38320000 Failed" bulleted item under APS934I to the following and 38330000 also change the title to "Open Session Failed". 38340000 38350000 - The target system is not executing the IBM printer 38360000 layer code. 38370000 38380000 - The printer is being used by another PSF FSA on the same 38390000 host. 38400000 38410000 -----------CHANGES FOR OW36155---------------------------------- 38420000 38430000 On page 247 add the following new conditions to the list of 38440000 conditions for the APS923I message: 38450000 38460000 o Out of staples 38470000 o Staple jam 38480000 o Too many sheets for a finishing operation 38490000 o Post processor has discarded pages 38500000 o Finishing mechanism exception 38510000 o Post processor not ready 38520000 38530000 -----------CHANGES FOR OW36506---------------------------------- 38540000 38550000 1. On page 94, change APS359I to read: 38560000 38570000 APS359I AN INTERNAL MEDIUM MAP WAS 38580000 ENCOUNTERED IN THE DATA SET BUT 38590000 INTERNAL MEDIUM MAPS ARE NOT 38600000 SUPPORTED. 38610000 2. On page 94, under APS359I, change the Explanation to read: 38620000 38630000 Explanation: A Begin Medium Map (BMM) structured 38640000 field was encountered in the data stream after 38650000 resources for the data set had been processed. 38660000 PSF/MVS does not support internal medium maps 38670000 between pages. The data set may have been created 38680000 by a program that creates internal medium maps, but 38690000 a data set that contains internal medium maps 38700000 cannot be printed. 38710000 38720000 2. On page 94, under APS359I, change the User Response to read: 38730000 38740000 User Response: If you are attempting to print a data 38750000 set containing internal medium maps, the data set 38760000 cannot be printed on PSF/MVS. If you are not 38770000 attempting to print a data set with internal medium 38780000 maps, and if you created the structured fields for the 38790000 print data set, correct the error and resubmit the print 38800000 request. For more information about the structured 38810000 field, refer to Mixed Object Document Content 38820000 Architecture Reference. If the structured field has no 38830000 error, the error may be a PSF logic error. If you used 38840000 a program to create the structured fields for the print 38850000 data set, consult your system programmer. 38860000 38870000 -----------CHANGES FOR OW37992---------------------------------- 38880000 38890000 1. On page 164 change message APS621I to read as follows. 38900000 38910000 APS621I OPERATOR INTERFACE INITIALIZED FOR product and version. 38920000 38930000 Explanation: The operator interface has been initialized 38940000 successfully. All operator commands can now be entered for the 38950000 PSF version or Download version that is specified. 38960000 38970000 System Action: Initialization continues. 38980000 38990000 User Response: No response is necessary. 39000000 39010000 System Programmer Response: No response is necessary. 39020000 39030000 Operator Response: Operator commands can now be entered. 39040000 39050000 Problem Determination: None 39060000 39070000 39080000 2. On page 261 change message APS992I to read as follows. 39090000 39100000 APS992I download version INITIALIZED. 39110000 39120000 Explanation: The download version specified was initialized 39130000 successfully. 39140000 39150000 System Action: The download FSA is ready to receive data sets 39160000 from the JES spool and transmit them to servers on AIX systems. 39170000 39180000 User Response: No response is necessary. 39190000 39200000 System Programmer Response: No response is necessary. 39210000 39220000 Operator Response: No response is necessary. 39230000 39240000 Problem Determination: None. 39250000 39260000 -----------CHANGES FOR OW38417---------------------------------- 39270000 39280000 1. On page 40 change the explanation and user response of message 39290000 APS188I to read as follows. 39300000 39310000 EXPLANATION: The Medium Copy Count (MCC) structured field 39320000 refers to one or more Medium Modification Control (MMC) 39330000 structured fields, which include requests for more than one 39340000 input source or media type local ID. You cannot specify more 39350000 than one input source or media type local ID for multiple copy 39360000 groups, because the printer you are using does not support it. 39370000 The MCC and MMC structured fields are in the form definition. 39380000 Media type local IDs are not supported on this version of PSF. 39390000 39400000 39410000 USER RESPONSE: Request that the job be printed on a printer 39420000 that supports the specification of input source in the Load Copy 39430000 Control (LCC) command. If you created the structured fields for 39440000 the form definition, correct the MMC structured field and 39450000 resubmit the print request. Media type local IDs will not 39460000 be honored by this version of PSF. Refer to Mixed Object Document 39470000 Content Architecture Reference for more information about the 39480000 structured field. If the MMC has no errors, the error may be a 39490000 PSF or printer logic error. If you used a program to create the 39500000 structured fields for the form definition, contact your system 39510000 programmer. 39520000 39530000 2. On page 45 change the message text, explanation, system action, 39540000 user response and system programmer response of message 39550000 APS210I to read as follows. 39560000 39570000 APS210I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: A 39580000 REQUIRED TRIPLET OR SELF-DEFINING PARAMETER WITH ID id 39590000 WAS MISSING FROM A structured field name STRUCTURED 39600000 FIELD. 39610000 39620000 EXPLANATION: The triplet or self-defining parameter specified 39630000 in the message was not found in the structured field indicated. 39640000 This is a required triplet or self-defining parameter. 39650000 39660000 SYSTEM ACTION: 39670000 39680000 If the structured field is included in an object embedded in a 39690000 page or overlay OR the structured field is in a resource 39700000 included by a page or overlay, PSF terminates the page or 39710000 overlay. PSF attempts to locate the end of the current page 39720000 and resume processing on the next page. If the end of the 39730000 current page cannot be located, PSF stops printing the data set. 39740000 39750000 For non-presentation object containers, PSF stops printing the 39760000 data set. 39770000 39780000 If the error is contained in a page definition or form 39790000 definition, PSF terminates processing of the data set and 39800000 continues processing with the next data set. 39810000 39820000 PSF issues a message that identifies the position of the 39830000 structured field in the input data stream or resource. PSF 39840000 issues additional messages identifying the processing 39850000 environment in which the error occurred. 39860000 39870000 USER RESPONSE: If you created the structured fields, correct 39880000 the error and resubmit the print request. Refer to Mixed Object 39890000 Document Content Architecture Reference and Advanced Function 39900000 Presentation: Programming Guide and Line Data Reference for 39910000 more information about the structured field. If the structured 39920000 field has no error, the error may be a PSF logic error. If you 39930000 used a program to create the structured fields, contact your 39940000 system programmer. 39950000 39960000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 39970000 to create the structured field with the error, verify that the 39980000 input to that program was valid. If the input was valid, refer 39990000 to PSF for OS/390: Diagnosis for assistance in determining the 40000000 source of the problem. If the error involves separator pages or 40010000 the message data set, use the information provided in the User 40020000 Response section to correct the error. 40030000 40040000 3. On page 48 change the message text and explanation of message 40050000 APS219I to read as follows. 40060000 40070000 APS219I THE INPUT BIN WITH COMPONENT ID component id, MEDIA NAME 40080000 media name, BIN NUMBER bin number WAS DISABLED. AN 40090000 ALTERNATE BIN WAS SUBSTITUTED. 40100000 40110000 EXPLANATION: The Medium Modification Control (MMC) structured 40120000 field requested an input bin that is supported by the printer 40130000 but was disabled. A value of *** for any of the three values 40140000 means that piece of information was not provided by the MMC 40150000 structured field. The input bin is selected by a media source 40160000 selector keyword in the MMC structured field. The media type local 40170000 ID keywords specify the ID of a Map Media Type (MMT) structured 40180000 field that contains an Object Identifier (OID) and/or Media Name 40190000 (this function is not supported on this version of PSF). 40200000 The MMC and MMT structured fields are contained in the form 40210000 definition. 40220000 40230000 4. On page 58 change the message text, explanation, & system action 40240000 of message APS255I to read as follows. 40250000 40260000 APS255I THE INPUT BIN WITH COMPONENT ID component id, MEDIA NAME 40270000 media name, BIN NUMBER bin number WAS NOT SUPPORTED ON 40280000 THE PRINTER. AN ALTERNATE BIN WAS SUBSTITUTED. 40290000 40300000 EXPLANATION: The Medium Modification Control (MMC) structured 40310000 field specified a media selection that does not exist on the 40320000 selected printer. A value of *** for any of the three values 40330000 means that piece of information was not provided by the MMC 40340000 structured field. The input bin is selected by a media source 40350000 selector keyword. The media type local ID keywords specify the 40360000 ID of a Map Media Type (MMT) structured field that contains an 40370000 Object Identifier (OID) and/or Media Name (this function is 40380000 not supported on this version of PSF). The MMC and MMT 40390000 structured fields are in the form definition. 40400000 40410000 SYSTEM ACTION: PSF issues this message and continues 40420000 processing, selecting paper from an alternate bin. 40430000 40440000 5. On page 91 delete message APS361I. 40450000 40460000 6. On page 92 change the explanation and user response of message 40470000 APS364I to read as follows. 40480000 40490000 EXPLANATION: The Medium Modification Control (MMC) structured 40500000 fields referenced by the Medium Copy Count (MCC) structured 40510000 field repeating groups specify different input source or media 40520000 type local ID values along with either tumble or normal duplex. 40530000 This is an attempt to print the front and back sides of a sheet 40540000 from different input bins. Media type local IDs are not supported 40550000 by this version of PSF. 40560000 40570000 USER RESPONSE: If you created the structured fields for the 40580000 form definition, correct the error and resubmit the print 40590000 request. Media type local IDs will not be honored by this 40600000 version of PSF. For more information about the structured field, 40610000 refer to Mixed Object Document Content Architecture Reference. 40620000 If the structured field has no error, the error may be a PSF 40630000 logic error. If you used a program to create the structured 40640000 fields for the form definition, consult your system programmer. 40650000 40660000 7. On page 93 change the message text and explanation of message 40670000 APS365I to read as follows. 40680000 40690000 APS365I AN ENVELOPE OR MANUAL FEED INPUT BIN WITH COMPONENT ID 40700000 component id, MEDIA NAME media name, BIN NUMBER bin 40710000 number WAS REQUESTED, BUT IS NOT AVAILABLE ON THE 40720000 PRINTER. 40730000 40740000 EXPLANATION: The Medium Modification Control (MMC) structured 40750000 field requested an envelope or manual feed bin, but no bins 40760000 installed on the printer support the requested bin type. A 40770000 value of *** for any of the three values means that piece of 40780000 information was not provided by the MMC structured field. The 40790000 input bin is selected by a media source selector keyword in the 40800000 MMC structured field. The media type local ID keywords specify 40810000 the ID of a Map Media Type (MMT) structured field that contains 40820000 an Object Identifier (OID) and/or Media Name (this function is 40830000 not supported by this version of PSF). The MMC and MMT 40840000 structured fields are in the form definition. 40850000 40860000 8. On page 97 change the message text, explanation and user response 40870000 of message APS385I to read as follows. 40880000 40890000 APS385I DATA IN A FORMDEF RESOURCE IS INVALID: THE MODIFICATIONS 40900000 SPECIFIED IN THE MMC STRUCTURED FIELD (identifier) 40910000 INCLUDE UNPAIRED keyword1 AND keyword2 KEYWORDS. 40920000 40930000 EXPLANATION: 40940000 40950000 The keywords must be paired in the Medium Modification Control 40960000 (MMC) structured field. This form definition has one or the 40970000 other keyword but not both, or the keyword pairs are not 40980000 adjacent. The MMC structured field is contained in the form 40990000 definition. 41000000 41010000 USER RESPONSE: If you created the structured fields for the 41020000 form definition, correct the error and resubmit the print 41030000 request. Refer to Mixed Object Document Content Architecture 41040000 Reference for more information about the structured field. If 41050000 the structured field has no error, the error may be a PSF logic 41060000 error. If you used a program to create the structured fields for 41070000 the form definition, contact your system programmer. 41080000 41090000 9. On page 97 change the message text, explanation, system action, 41100000 user response, system programmer response, and problem 41110000 determination of message APS390I to read as follows. 41120000 41130000 APS390I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 41140000 structured field STRUCTURED FIELD CONTAINS A triplet 41150000 identifier TRIPLET THAT HAS AN INVALID VALUE. THE 41160000 INVALID VALUE STARTS IN BYTE offset OF THE TRIPLET. 41170000 41180000 EXPLANATION: An invalid value was specified for a field that 41190000 starts in byte offset of the triplet identified in this message. 41200000 The triplet is specified on the structured field identified in 41210000 this message. 41220000 41230000 SYSTEM ACTION: If the error occurred in a form definition, a 41240000 page definition, or a non-presentation object container resource 41250000 (for example, COMSETUP), the form definition, page definition, 41260000 or non-presentation object container resource is not used, and 41270000 one of the following occurs: 41280000 41290000 o PSF will not be started for any of the following: 41300000 41310000 - The default form definition 41320000 - A form definition specified for printing messages or 41330000 separator pages 41340000 - A page definition specified for printing messages or 41350000 separator pages 41360000 41370000 o PSF cannot begin printing the data set for a form definition 41380000 or non-presentation object container resource (or page 41390000 definition if printing line data) specified on a user's JCL 41400000 OUTPUT statement; PSF tries to print the next data set. 41410000 41420000 If the error occurred in a structured field in a page or another 41430000 type of resource, PSF attempts to find the end of the page or 41440000 resource. If PSF can find the end of the page or resource, it 41450000 prints any data accumulated for the current page. If PSF cannot 41460000 find the end of the page or resource, the data set is 41470000 terminated. 41480000 41490000 PSF issues a message identifying the position of the structured 41500000 field in the data stream or resource. PSF issues additional 41510000 messages identifying the processing environment in which the 41520000 error occurred. 41530000 41540000 USER RESPONSE: If you created the structured fields for the 41550000 object, correct the error and resubmit the print request. Refer 41560000 to Advanced Function Presentation: Programming Guide and Line 41570000 Data Reference and/or Mixed Object Document Content Architecture 41580000 Reference for more information about the structured field. If 41590000 the structured field has no error, the error may be a PSF logic 41600000 error. If you used a program to create the structured fields for 41610000 the object, contact your system programmer. 41620000 41630000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 41640000 to create the structured fields for the object with the error, 41650000 verify that the input to that program was valid. If the input 41660000 was valid, refer to PSF for OS/390: Diagnosis for assistance in 41670000 determining the source of the problem. If the error involves 41680000 separator pages or the message data set, use the information 41690000 provided in the User Response section to correct the error. 41700000 41710000 PROBLEM DETERMINATION: Items 2, 17. 41720000 41730000 10. On page 97 add the following 4 messages: 41740000 41750000 APS394I THE PSF OBJECT STACK IS ABOUT TO OVERFLOW DUE TO MISSING 41760000 END STRUCTURED FIELDS. 41770000 41780000 EXPLANATION: CCM has run out of its object stack area. The 41790000 cause could be a data stream error. A begin structured field 41800000 must be followed by a matching end structured field in the data 41810000 stream. If this requirement is not met, the CCM can run out of 41820000 its object stack area. A common cause of this problem is missing 41830000 EDT structured fields. 41840000 41850000 SYSTEM ACTION: PSF terminates the processing and printing of 41860000 this data set. 41870000 41880000 USER RESPONSE: If you created the data stream, each begin 41890000 structured field in the data stream must be followed by a 41900000 matching end structured field. Check the data stream to ensure 41910000 that it meets this requirement. If it does not meet the 41920000 requirement, correct the data stream. If it does meet the 41930000 requirement, this error code indicates a logic error. If you 41940000 believe the error is a logic error, consult your service 41950000 representative in the IBM Support Center for assistance, or use 41960000 your electronic link with IBM services. 41970000 41980000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 41990000 to create the data stream with the error, verify that the input 42000000 to that program was valid. If the input was valid, refer to PSF 42010000 for OS/390: Diagnosis for assistance in determining the source 42020000 of the problem. If the error involves separator pages or the 42030000 message data set, use the information provided in the User 42040000 Response section to correct the error. 42050000 42060000 PROBLEM DETERMINATION: Items 1, 2, 8, 13, 19 42070000 42080000 42090000 APS396I DATA IN A FORMDEF RESOURCE IS INVALID: THE 42100000 OUTPUT BIN SELECTION VALUE IN MMC STRUCTURED FIELD, ID 42110000 identifier, IS NOT ACCEPTABLE. 42120000 42130000 EXPLANATION: In the Medium Modification Control (MMC) 42140000 structured field whose identifier is specified in the message 42150000 text, the output bin selection parameter value was invalid. The MMC 42160000 structured field is contained in the form definition. This function 42170000 is not supported on this version of PSF. 42180000 42190000 SYSTEM ACTION: The form definition containing the error is not 42200000 used, and one of the following occurs: 42210000 42220000 o PSF is not initialized for either the default form 42230000 definition or a form definition specified for printing 42240000 messages or separator pages. 42250000 42260000 o PSF cannot begin printing the data set for a form definition 42270000 specified on a user's JCL OUTPUT statement; it tries to 42280000 print the next data set. 42290000 42300000 PSF issues a message identifying the position of the structured 42310000 field in the form definition. PSF issues additional messages 42320000 identifying the processing environment in which the error 42330000 occurred. 42340000 42350000 USER RESPONSE: If you created the structured fields for the 42360000 form definition, correct the MMC structured field and resubmit 42370000 the print request. The output bin selection from the form 42380000 definition will not be honored on this version of PSF. Refer to 42390000 Mixed Object Document Content Architecture Reference and Advanced 42400000 Function Presentation: Programming Guide and Line Data Reference 42410000 for more information about the structured field. If the MMC has 42420000 no errors, the error may be a PSF logic error. If you used a 42430000 program to create the structured fields for the form definition, 42440000 contact your system programmer. 42450000 42460000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 42470000 to create the structured fields for the form definition with the 42480000 error, verify that the input to that program was valid. If the 42490000 input was valid, refer to Advanced Function Printing: Diagnosis 42500000 Guide and Print Services Facility/MVS: Diagnosis Guide and 42510000 Reference for assistance in determining the source of the 42520000 problem. If the error involves separator pages or the message 42530000 data set, use the information provided in the User Response 42540000 section to correct the error. 42550000 42560000 OPERATOR RESPONSE: If this message displays on the operator's 42570000 console, it indicates that the resource containing the error is 42580000 defined for a separator page, for the message data set, or as 42590000 the default resource for user print data sets in the PSF startup 42600000 procedure. Inform your system programmer. 42610000 42620000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 42630000 42640000 42650000 42660000 APS397I THE SET OF MODIFICATIONS SPECIFIED IN THE MCC STRUCTURED 42670000 FIELD INDICATES DIFFERENT OUTPUT BIN VALUES FOR 42680000 THE FRONT AND BACK SIDES OF A DUPLEX SHEET. 42690000 42700000 EXPLANATION: The Medium Modification Control (MMC) structured 42710000 fields referenced by the Medium Copy Count (MCC) structured 42720000 field repeating groups specify different output bin values 42730000 along with either tumble or normal duplex. This is an attempt 42740000 to place the front and back sides of a sheet into different 42750000 output bins. Output bin selection from a form definition is 42760000 not supported by this version of PSF. 42770000 42780000 SYSTEM ACTION: The form definition containing the error is not 42790000 used, and one of the following occurs: 42800000 42810000 o PSF is not initialized for either the default form 42820000 definition or a form definition specified for printing 42830000 messages or separator pages. 42840000 42850000 o PSF cannot begin printing the data set for a form definition 42860000 specified on a user's JCL OUTPUT statement, and tried to 42870000 print the next data set. 42880000 42890000 PSF issues a message identifying the position of the structured 42900000 field in the form definition. PSF issues additional messages 42910000 identifying the processing environment when the error was found. 42920000 42930000 USER RESPONSE: If you created the structured fields for the 42940000 form definition, correct the MMC structured field and resubmit 42950000 the print request. The output bin selection from the form 42960000 definition will not be honored on this version of PSF. Refer to 42970000 Mixed Object Document Content Architecture Reference and Advanced 42980000 Function Presentation: Programming Guide and Line Data Reference 42990000 for more information about the structured field. If the MMC has 43000000 no errors, the error may be a PSF logic error. If you used a 43010000 program to create the structured fields for the form definition, 43020000 contact your system programmer. 43030000 43040000 SYSTEM PROGRAMMER RESPONSE: If the error involves separator 43050000 pages or the message data set, use the information provided in 43060000 the User Response section to correct the error. 43070000 43080000 OPERATOR RESPONSE: If this message displays on the operator's 43090000 console, it indicates that the resource containing the error is 43100000 defined for a separator page, for the message data set, or as 43110000 the default resource for user print data sets in the PSF startup 43120000 procedure. Inform your system programmer. 43130000 43140000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 43150000 43160000 43170000 43180000 APS398I DATA IN A FORMDEF RESOURCE IS INVALID: THE SET OF 43190000 MODIFICATIONS SPECIFIED IN THE MMC STRUCTURED FIELD 43200000 INCLUDES DUPLICATE CONFLICTING VALUES FOR THE keyword 43210000 KEYWORD. 43220000 43230000 EXPLANATION: The Medium Modification Control (MMC) structured 43240000 field contains duplicate conflicting values for the keyword 43250000 identified in the message text. The MMC structured field is in 43260000 the form definition. Output bin selection from a form definition 43270000 is not supported by this version of PSF. 43280000 43290000 SYSTEM ACTION: PSF issues this message and continues processing, 43300000 ignoring the duplicate keyword. 43310000 43320000 USER RESPONSE: If you created the structured fields for the 43330000 form definition, correct the MMC structured field and resubmit 43340000 the print request. The output bin selection from the form 43350000 definition will not be honored on this version of PSF. Refer to 43360000 Mixed Object Document Content Architecture Reference and Advanced 43370000 Function Presentation: Programming Guide and Line Data Reference 43380000 for more information about the structured field. If the MMC has 43390000 no errors, the error may be a PSF logic error. If you used a 43400000 program to create the structured fields for the form definition, 43410000 contact your system programmer. 43420000 43430000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 43440000 to create the structured fields for the form definition with the 43450000 error, verify that the input to that program was valid. If the 43460000 input was valid, refer to Advanced Function Printing: Diagnosis 43470000 Guide and Print Services Facility/MVS: Diagnosis Guide and 43480000 Reference for assistance in determining the source of the 43490000 problem. If the error involves separator pages or the message 43500000 data set, use the information provided in the User Response 43510000 section to correct the error. 43520000 43530000 OPERATOR RESPONSE: If this message displays on the operator's 43540000 console, it indicates that the resource containing the error is 43550000 defined for a separator page, for the message data set, or as 43560000 the default resource for user print data sets in the PSF startup 43570000 procedure. Inform your system programmer. 43580000 43590000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 43600000 43610000 11. On page 258 add the following 2 messages: 43620000 43630000 APS2003I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: 43640000 STRUCTURED FIELD structured field CONTAINED AN EXTENDED 43650000 RESOURCE LOCAL IDENTIFIER VALUE THAT WAS USED IN A 43660000 PREVIOUS STRUCTURED FIELD OF THE SAME TYPE. 43670000 43680000 EXPLANATION: More than one structured field used the same 43690000 Extended Resource Local Identifier value for different resources 43700000 of the same type. The Extended Resource Local Identifier is 43710000 specified by using the Extended Resource Local Identifier (X'22') 43720000 triplet on the structured field. The structured field that 43730000 attempted to use the same Extended Resource Local Identifier 43740000 value is identified in the message (this function is not 43750000 supported on this version of PSF). 43760000 43770000 SYSTEM ACTION: PSF stops processing the current data set and 43780000 issues messages identifying the position of the structured field 43790000 and the processing environment when the error was found. 43800000 43810000 USER RESPONSE: If you created the structured fields for the 43820000 resource, correct the error and resubmit the print request. 43830000 The function requested by the structured field identified 43840000 in the message will not be honored on this version of PSF. 43850000 Refer to Advanced Function Presentation: Programming Guide and 43860000 Line Data Reference and/or Mixed Object Document Content 43870000 Architecture Reference for more information about the structured 43880000 field. If the structured field has no error, the error may be a 43890000 PSF logic error. If you used a program to create the structured 43900000 fields for the resource, contact your system programmer. 43910000 43920000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 43930000 to create the structured fields for the resource with the error, 43940000 verify that the input to that program was valid. If the input 43950000 was valid, refer to PSF for OS/390: Diagnosis for assistance in 43960000 determining the source of the problem. If the error involves 43970000 separator pages or the message data set, use the information 43980000 provided in the User Response section to correct the error. 43990000 44000000 OPERATOR RESPONSE: If this message displays on the operator's 44010000 console, it indicates that the resource containing the error is 44020000 defined for a separator page, for the message data set, or as 44030000 the default resource for user print data sets in the PSF startup 44040000 procedure. Inform your system programmer. 44050000 44060000 PROBLEM DETERMINATION: Items 1, 2, 3, 13, 15c, 17, 19. 44070000 44080000 44090000 APS2004I DATA IN A FORMDEF RESOURCE IS INVALID: MEDIA TYPE LOCAL 44100000 IDENTIFIER IN MMC STRUCTURED FIELD, ID identifier, WAS 44110000 NOT FOUND IN THE MMT STRUCTURED FIELD. 44120000 44130000 EXPLANATION: The Media Type local ID in the Medium Modification 44140000 Control (MMC) structured field was not present in the Map Media 44150000 Type (MMT) structured field. The MMC and MMT structured fields 44160000 are in the form definition. This function is not supported by 44170000 this version of PSF. 44180000 44190000 SYSTEM ACTION: The form definition containing the error is not 44200000 used, and one of the following occurs: 44210000 44220000 o If the error is in the default form definition, or a form 44230000 definition specified for printing messages or separator 44240000 pages, PSF is not started. 44250000 44260000 o If the error is in a form definition specified on the user's 44270000 JCL OUTPUT statement, PSF cannot begin printing the data 44280000 set; it tries to print the next data set. 44290000 44300000 USER RESPONSE: If you created the structured fields for the 44310000 form definition, correct the error and resubmit the print 44320000 request. The media type local ID will not be honored by this 44330000 version of PSF. Refer to Mixed Object Document Content 44340000 Architecture Reference for more information about the structured 44350000 field. If the structured field has no error, the error may be a 44360000 PSF logic error. If you used a program to create the structured 44370000 fields for the form definition, contact your system programmer. 44380000 44390000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 44400000 to create the structured fields for the form definition with the 44410000 error, verify that the input to that program was valid. If the 44420000 input was valid, refer to PSF for OS/390: Diagnosis for 44430000 assistance in determining the source of the problem. If the 44440000 error involves separator pages or the message data set, use the 44450000 information provided in the User Response section to correct the 44460000 error. 44470000 44480000 OPERATOR RESPONSE: If this message displays on the operator's 44490000 console, it indicates that the resource containing the error is 44500000 defined for a separator page, for the message data set, or as 44510000 the default resource for user print data sets in the PSF startup 44520000 procedure. Inform your system programmer. 44530000 44540000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 44550000 44560000 -----------CHANGES FOR OW39266---------------------------------- 00860000 1. MSGAPS249I changes : On page 57, under APS249I, change the System Action section to read: System Action: PSF cannot print the current data set. PSF stops processing and printing the data set. PSF issues additional messages identifying the processing environment in which the error occurred. PSF releases the current data set back to JES and requests that it be held by the system, unless PRTERROR=QUIT was specified on the OUTPUT statement. On page 58, for APS249I, change the User Response to read: User Response: If you do not want MICR fonts, correct the error. If you do want MICR fonts, verify that the printer supports MICR. If it does, verify that it is enabled. 2. Add message: APS399I OUTPUT BIN bin number WAS REQUESTED FOR THE JOB, BUT IT WAS NOT AVAILABLE OR THE PRINTER DOES NOT SUPPORT OUTPUT BIN SELECTION. Explanation: The OUTBIN keyword on the JCL OUTPUT statement or the output bin selection parameter value in the form definition specified an output bin. Either that bin is not available or the printer does not support output bin specification. Since mandatory print labeling is enabled, the data set cannot be processed. System Action: PSF cannot print the current data set. PSF stops processing and printing the data set. PSF issues additional messages identifying the processing environment in which the error occurred. PSF releases the current data set back to JES and requests that it be held by the system, unless PRTERROR=QUIT was specified on the OUTPUT statement. User Response: Users have several options to correct or avoid this error: € Resubmit the print request to a printer that supports the requested bin number. € If the bin number was specified on the JCL OUTPUT statement, change the OUTBIN keyword to a bin number that is supported by the printer and resubmit the print request. If the bin number specified by the OUTBIN keyword is supported by the printer, the error may be a PSF logic error. € If you created the structured fields for the form definition, change the MMC structured field, specifying the correct output bin selection parameter value that is supported by the printer and resubmit the print request. Refer to Mixed Object Document Content Architecture Reference and Advanced Function Presentation: Programming Guide and Line Data Reference for more information about the structured field. If the MMC output bin selection parameter is supported by the printer, the error may be a PSF logic error. If you used a program to create the structured fields for the form definition, contact your system programmer. € Disable mandatory print labeling and resubmit the print request. € If you print to a printer that does not support output bin specification, remove the output bin specification. System Programmer Response: If the error involves separator pages or the message data set, use the information provided in the User Response section to correct the error. Operator Response: Inform your system programmer that this error occurred. Problem Determination: Items 1, 2, 8, 19. 00850000 -----------CHANGES FOR OW40216---------------------------------- 00860000 Add abend code: 00870000 01F9 Explanation: This abend is issued by module APSPPDVP. The system function for OPEN of the PSF resource libraries did not succeed. The PSF resource libraries had been closed and there was an attempt to re-open them and the re-open failed. System Action: PSF processing terminates abnormally. System Programmer Response: If Data Management messages preceded by IEC are received, use the information provided by these messages to recover from the open failure before contacting the IBM Support Center or using your electronic link with IBM service for assistance. 01FA Explanation: This abend is issued by module APSPPDVP. The close request for the PSF resource libraries failed. PSF was trying to close the PSF resource libraries because no work is available for this printer and the close failed. System Action: PSF processing terminates abnormally. System Programmer Response: If Data Management messages preceded by IEC are received, use the information provided by these messages to recover from the close failure before contacting the IBM Support Center or using your electronic link with IBM service for assistance. 0525 Explanation: This abend is issued by module APSDDS. The system function for OPEN of the PSF resource libraries did not succeed. This is the initial attempt at opening the PSF resource libraries. System Action: PSF processing terminates abnormally. System Programmer Response: If Data Management messages preceded by IEC are received, use the information provided by these messages to recover from the open failure before contacting the IBM Support Center or using your electronic link with IBM service for assistance. 06480000 -----------CHANGES FOR OW39931---------------------------------------- 06490000 Delete the following messages: 06500000 APS382I 06510000 06520000 1. Change message as follows: 06760000 06770000 APS386I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: A 06780000 REQUIRED TRIPLET WITH ID identifier WAS MISSING FROM AN 06790000 IOB STRUCTURED FIELD. 06800000 06810000 EXPLANATION: 06820000 06830000 When identifier is X'4C': 06840000 06850000 o The x- or y-axis origin for object content or an object area 06860000 size (X'4C') triplet was specified on an IOB, but no 06870000 measurement unit (X'4B') triplet was specified. 06880000 06890000 The structured field is contained in a print data set or 06900000 overlay. 06910000 06920000 When identifier is X'22': 06930000 06940000 o The Extended Resource Local Identifier (X'22') triplet is 06950000 required when the IOB structured field is contained in a 06960000 page definition. 06970000 06980000 SYSTEM ACTION: If the error is contained in a page definition, 06990000 PSF terminates processing of the data set and continues 07000000 processing with the next data set. Otherwise, PSF terminates 07010000 the page or overlay containing the structured field in error. 07020000 PSF attempts to locate the end of the current page and resume 07030000 processing on the next page. If the end of the current page 07040000 cannot be located, PSF stops printing the data set. 07050000 07060000 PSF issues a message identifying the position of the structured 07070000 field in the input data stream or resource. PSF issues 07080000 additional messages identifying the processing environment when 07090000 the error was found. 07100000 07110000 USER RESPONSE: If you placed the IOB structured field in the 07120000 print data set or resource, correct the error and resubmit the 07130000 print request. Refer to Mixed Object Document Content 07140000 Architecture Reference and Advanced Function Presentation: 07150000 Programming Guide and Line Data Reference for more information 07160000 about the structured field. If you used a program to place the 07170000 IOB structured field in the print data set or resource, contact 07180000 your system programmer. 07190000 07200000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 07210000 to place the IOB structured field in the print data set or 07220000 resource, verify that the input to that program was valid. If it 07230000 was valid, refer to PSF for OS/390: Diagnosis for assistance in 07240000 determining the source of the problem. 07250000 07260000 OPERATOR RESPONSE: No response is necessary. 07270000 07280000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 07290000 07300000 2. Add message as follows: 09150000 09160000 APS367I DATA IN A PAGEDEF RESOURCE IS INVALID: THE OUTPUT OPTION 09170000 SPECIFIED IN AN IOB STRUCTURED FIELD WITH RESOURCE LOCAL 09180000 ID identifier IS INVALID OR UNSUPPORTED. THE IOB IS 09190000 INCLUDED WITH LND STRUCTURED FIELD NUMBER structured 09200000 field number. 09210000 09220000 EXPLANATION: The Include Object (IOB) structured field in error 09230000 contained an invalid Output Option value, or the printer does 09240000 not support the Output Option value. The IOB is included using 09250000 the Line Descriptor (LND) structured field identified in this 09260000 message. The IOB and LND structured fields are both contained 09270000 in the page definition. 09280000 09290000 SYSTEM ACTION: PSF stops processing the current data set and 09300000 issues additional messages identify the processing environment 09310000 when the error was found. 09320000 09330000 USER RESPONSE: If you created the structured fields for the 09340000 page definition, correct the error and resubmit the print 09350000 request. Refer to Advanced Function Presentation: Programming 09360000 Guide and Line Data Reference and Mixed Object Document Content 09370000 Architecture Reference for more information about the structured 09380000 field. If the structured field has no error, the error may be a 09390000 PSF logic error. If you used a program to create the structured 09400000 fields for the page definition, contact your system programmer. 09410000 09420000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 09430000 to create the structured fields for the page definition with the 09440000 error, verify that the input to that program was valid. If the 09450000 input was valid, refer to PSF for OS/390: Diagnosis for 09460000 assistance in determining the source of the problem. 09470000 09480000 OPERATOR RESPONSE: If this message displays on the operator's 09490000 console, it indicates that the resource containing the error is 09500000 defined for a separator page or the message data set in the PSF 09510000 startup procedure. Inform your system programmer. 09520000 09530000 PROBLEM DETERMINATION: Items 1, 2, 13, 15c, 17, 19. 09540000 09550000 3. Add message as follows: 09560000 09570000 APS368I DATA IN A PAGEDEF RESOURCE IS INVALID: THE RESOURCE LOCAL 09580000 ID identifier SPECIFIED IN THE EXTENDED RESOURCE LOCAL ID 09590000 TRIPLET ON LND STRUCTURED FIELD NUMBER structured field 09600000 number WAS NOT FOUND. 09610000 09620000 EXPLANATION: In the Line Descriptor (LND) structured field, an 09630000 Extended Resource Local Identifier triplet specifies a local ID, 09640000 identifier, of an Include Object (IOB) structured field that is 09650000 to be used to include an object when this LND is used for 09660000 printing. The identifier specified on the LND does not match 09670000 any of the IOB structured fields contained in the page 09680000 definition. 09690000 09700000 SYSTEM ACTION: PSF stops processing the current data set and 09710000 issues additional messages that identify the processing 09720000 environment when the error was found. 09730000 09740000 USER RESPONSE: If you created the structured fields for the 09750000 page definition, correct the error and resubmit the print 09760000 request. Refer to Advanced Function Presentation: Programming 09770000 Guide and Line Data Reference and Mixed Object Document Content 09780000 Architecture Reference for more information about the structured 09790000 field. If the structured field has no error, the error may be a 09800000 PSF logic error. If you used a program to create the structured 09810000 fields for the page definition, contact your system programmer. 09820000 09830000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 09840000 to create the structured fields for the page definition with the 09850000 error, verify that the input to that program was valid. If the 09860000 input was valid, refer to PSF for OS/390: Diagnosis for 09870000 assistance in determining the source of the problem. If the 09880000 error involves separator pages or the message data set, use the 09890000 information provided in the User Response section to correct the 09900000 error. 09910000 09920000 OPERATOR RESPONSE: If this message displays on the operator's 09930000 console, it indicates that PSF cannot be initialized or cannot 09940000 print a separator page or error messages. Inform your system 09950000 programmer that this error occurred. 09960000 09970000 PROBLEM DETERMINATION: Items 2, 17, 27. 09980000 08690000 4. Add message as follows: 08700000 08710000 APS369I DATA IN AN INPUT RECORD IS INVALID: AN IOB STRUCTURED 08720000 FIELD IS ATTEMPTING TO INCLUDE A NON-PRESENTATION OBJECT 08730000 CONTAINER. 08740000 08750000 EXPLANATION: The Object Classification, X'10', triplet on an 08760000 Include Object (IOB) structured field is requesting a 08770000 non-presentation object as the object class. Only presentation 08780000 objects are allowed to be included via an IOB structured field. 08790000 The IOB structured field is contained in the print data set, an 08800000 overlay or a page definition. 08810000 08820000 SYSTEM ACTION: If the IOB is in a print data set or an overlay, 08830000 PSF terminates the page or overlay containing the structured 08840000 field in error. PSF attempts to locate the end of the current 08850000 page and resume processing on the next page. If the end of the 08860000 current page cannot be located, PSF stops printing the data set. 08870000 08880000 If the error is contained in a page definition, PSF terminates 08890000 processing of the data set and continues processing with the 08900000 next data set. 08910000 08920000 PSF issues a message identifying the position of the structured 08930000 field in the input data stream or resource. PSF issues 08940000 additional messages identifying the processing environment when 08950000 the error was found. 08960000 08970000 USER RESPONSE: If you created the IOB structured field, correct 08980000 the error and resubmit the print request. Refer to Mixed Object 08990000 Document Content Architecture Reference and Advanced Function 09000000 Presentation: Programming Guide and Line Data Reference for more 09010000 information about the structured field. If you used a program to 09020000 create the IOB structured field, contact your system programmer. 09030000 09040000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 09050000 to create the IOB structured field, verify that the input to 09060000 that program was valid. If it was valid, refer to PSF for 09070000 OS/390: Diagnosis for assistance in determining the source of 09080000 the problem. 09090000 09100000 OPERATOR RESPONSE: No response is necessary. 09110000 09120000 PROBLEM DETERMINATION: Items 2, 13, 17. 09130000 09140000 09990000 5. Add message as follows: 10000000 10010000 APS381I DATA IN AN INPUT RECORD OR RESOURCE IS INVALID: THE 10020000 REGISTERED OBJECT ID IN THE OBJECT CLASSIFICATION 10030000 TRIPLET ON A structured field name STRUCTURED 10040000 FIELD IS NOT SPECIFIED 10050000 10060000 EXPLANATION: The registered object ID is 0 in the object 10070000 classification triplet. Object containers require a 10080000 registered ID to be specified. 10090000 10100000 SYSTEM ACTION: 10110000 10120000 If the structured field is included in an object embedded in a 10130000 page or overlay OR the structured field is in a resource 10140000 included by a page or overlay, PSF terminates the page or 10150000 overlay. PSF attempts to locate the end of the current page 10160000 and resume processing on the next page. If the end of the 10170000 current page cannot be located, PSF stops printing the data set. 10180000 10190000 For non-presentation object containers, PSF stops printing the 10200000 data set. 10210000 10220000 If the error is contained in a page definition, PSF terminates 10230000 processing of the data set and continues processing with the 10240000 next data set. 10250000 10260000 PSF issues a message that identifies the position of the 10270000 structured field in the input data stream or resource. PSF 10280000 issues additional messages identifying the processing 10290000 environment in which the error occurred. 10300000 10310000 USER RESPONSE: If you created the structured fields, correct 10320000 the error and resubmit the print request. Refer to Mixed Object 10330000 Document Content Architecture Reference and Advanced Function 10340000 Presentation: Programming Guide and Line Data Reference for 10350000 more information about the structured field. If the structured 10360000 field has no error, the error may be a PSF logic error. If you 10370000 used a program to create the structured fields, contact your 10380000 system programmer. 10390000 10400000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 10410000 to create the structured field with the error, verify that the 10420000 input to that program was valid. If the input was valid, refer 10430000 to PSF for OS/390: Diagnosis for assistance in determining the 10440000 source of the problem. If the error involves separator pages or 10450000 the message data set, use the information provided in the User 10460000 Response section to correct the error. 10470000 10480000 OPERATOR RESPONSE: If this message displays on the operator's 10490000 console, it indicates that the resource containing the error is 10500000 defined for a separator page, for the message data set, or as 10510000 the default resource for user print data sets in the PSF startup 10520000 procedure. Inform your system programmer. 10530000 10540000 PROBLEM DETERMINATION: Items 2, 13, 17. 10550000 10650000 6. Add message as follows: 10660000 10670000 APS2000I THE REGISTERED OBJECT ID ('registration id') OF AN 10680000 OBJECT CONTAINER RESOURCE, resource name, IS INVALID 10690000 OR IS NOT SUPPORTED BY PSF OR THE PRINTER. 10700000 10710000 EXPLANATION: The registration ID specified for an object 10720000 container is invalid or is not supported by PSF or the printer. The registration ID is specified in the object classification triplet on an IOB, BOC, or BR structured field. 10740000 10760000 SYSTEM ACTION: PSF terminates the page or overlay. PSF 10770000 attempts to locate the end of the current page and resume 10780000 processing on the next page. If the end of the current page 10790000 cannot be located, PSF stops printing the data set. PSF issues 10800000 additional messages that identify the processing environment 10810000 when the error was found. 10820000 10830000 USER RESPONSE: If you created the structured fields for the 10840000 object container resource, ensure that the registered object 10850000 ID is correct. 10860000 If the registered object ID is correct: o And this printer does not support this object type, submit the job to a printer that supports this object type. 10870000 o And this printer supports this object type, Inform your system programmer. 10860000 For more information about what object types are supported by your 10880000 printer, refer to your printer documentation. 10890000 10900000 SYSTEM PROGRAMMER RESPONSE: If an IBM licensed program was used 10910000 to create the structured fields, verify that the input to that 10920000 program was valid. If the input was valid: o Determine if your printer supports this registered object ID. If your printer supports this registered object ID, this indicates that PSF does not. A later version of PSF may support this object type, contact your service representative in the IBM Support Center or use your electronic link with IBM service for assistance regarding this error code. o Refer to Advanced Function Printing: Diagnosis Guide and Print Services Facility/MVS: Diagnosis Guide and Reference for assistance in determining the source of the problem. 10950000 If the error involves separator pages or the 10950000 message data set, use the information provided in the User 10960000 Response section to correct the error. 10970000 10980000 OPERATOR RESPONSE: If this message displays on the operator's 10990000 console, it indicates that the resource containing the error is 11000000 defined for a separator page, for the message data set, or as 11010000 the default resource for user print data sets in the PSF startup 11020000 procedure. Inform your system programmer. 11030000 11040000 PROBLEM DETERMINATION: Items 1, 2, 13, 17, 19. 11050000 11060000 34660000 7. Add new abend reason code as follows: 34670000 34680000 08D6 34690000 34700000 EXPLANATION: This abend is issued by module APRMSGEX-- No 34710000 record length was passed to CCM when processing an object 34720000 container resource. This is a logic error. 34730000 34740000 SYSTEM ACTION: PSF attempts to recover from this abend by 34750000 restarting. Message APS057I is issued if PSF successfully 34760000 restarts. 34770000 34780000 SYSTEM PROGRAMMER RESPONSE: This PSF abend reason code 34790000 indicates a logic error. Contact your service representative in 34800000 the IBM Support Center or use your electronic link with IBM 34810000 service for assistance regarding this error code. 34820000 34830000 -----------CHANGES FOR OW41705---------------------------------------- 06490000 APS151I THE PRINTABLE AREA LENGTH OF inches INCHES IS TOO SMALL TO PRINT MESSAGES. PSF HAS USED THE SMALLEST LENGTH FROM THE LOGICAL PAGE inches OR THE PHYSICAL PRINTABLE AREA inches OR THE USER PRINTABLE AREA inches. PRINTING OF MESSAGES IS TERMINATED. Explanation: A check was made to determine whether the message would fit in the printable area when printed on the paper size currently in the printer. It was determined that there was not enough space for even one message line. The page length specified is too small. System Action: The message dataset or interrupt message page is not printed. User Response: If the FORMLEN keyword has been specified in the user's OUTPUT JCL statement and this value is too small, increase the FORMLEN value and resubmit the job. The FORMLEN value is used for both the message dataset and the interrupt message page. See the PSF/MVS Application Programming Guide for details on the FORMLEN keyword. If this does not fix the problem, inform your system programmer. System Programmer Response: If messages are to be printed, select a form, a logical page size, and a font size that allows messages to fit on the page. The form definition or page definition selected to process messages may be incorrect, or the font selected may be too large for the page size specified in the form definition or the page definition. In addition, the physical printable area length (form length) as returned in the XOH Obtain Printer Characteristics reply may be too small. PSF uses the smallest of the: 1) User Printable Area length plus its vertical offset, 2) the physical printable area length, or 3) the current logical page length plus its vertical offset to determine the printable area. The aforementioned printable area lengths are further reduced by any vertical offset from the medium origin (specified in the formdef), and by an additional .36 inches for all printers except the 3800 where .67 inches is used. 1. Use the smallest length as specified in the message and: o If the logical page length is too small, correct the length in the pagedef for the message dataset. See IBM Page Printer Formatting Aid: User's Guide for assistance. o If the physical page length(forms length) is too small and the forms length may be configured via the printer's operator panel, perform the action specified in the "Operator Response". o If the User Printable Area (UPA) is too small, see the PSF Security Guide for assistance. Note: All the values above are affected by the offset from the medium origin as specified in the formdef for the message dataset. Check this value to ensure the offset is not too large. See IBM Page Printer Formatting Aid: User's Guide for assistance. 2. See the "User Response" section if it can be determined that the submittor of the job has specified the FORMLEN keyword and the FORMLEN value is too small. 3. If the specified page length is not too small, it could be because PSF calculated an incorrect maximum page length. Operator Response: If the physical printable area length (forms length) may be configured by the operator and it's determined this is the problem, increase the printable area length (forms length) and resubmit the job. See the printer hardware manual for details on configuring forms length. Otherwise, inform your system programmer that this error has occurred. Problem Determination: Items 1, 17, 19. 00850000 -----------CHANGES FOR OW42286---------------------------------- 00860000 after last bullet in explanation for message APS502I, add 00870000 following bullet: o Failed to include a FONTDD, PSEGDD or OVLYDD default on the PRINTDEV statement when using multiple resolution. -----------CHANGES FOR OW42838---------------------------------- 00860000 1. On page 251 for APS935I under the common ERRNOs in the explanation add errno 0 as follows. 0 See the previous message for a description of the problem. 2. Add message APS6500I. APS6500I UNEXPECTED SESSION ENDING RESPONSE RECEIVED FROM THE PRINTER. Explanation: An unexpected response was received from the printer that ended the TCP/IP session prematurely. System Action: If a data set was being printed at the time the session ended, the data set may be restarted from the most recent checkpoint before the session was ended or may be restarted from the beginning if no checkpoint had occurred. - If connecting to the printer and FAILURE=WCONNECT, PSF will issue message APS935I and the connect will be retried until the connect interval timer expires (CONNINTV). - If connecting to the printer and FAILURE=STOP, PSF will terminate the FSA and issue APS934I. - If attempting to send data and FAILURE=STOP, PSF will terminate the FSA and issue APS934I. - If attempting to send data and FAILURE=WCONNECT, PSF will issue messages APS932I and APS6501I and attempt to restablish the connection. User Response: Examine your output for duplicate pages. System Programmer Response: This indicates a possible logic error in the microcode of the printer or another problem with the printer. Consult your hardware service provider or the person responsible for the printer for assistance. Operator Response: No response is necessary. Problem Determination: Items 1, 18. 3. Add message APS6501I. APS6501I AN UNEXPECTED COMMUNICATION FAILURE OCCURRED. PRINTING WILL BE RESTARTED AT A PREVIOUS CHECKPOINT, AND PAGES MAY BE DUPLICATED. Explanation: PSF detected an unexpected failure in communication with the printer; for instance, the session was lost during page processing. Some pages may have printed, of which PSF was not informed. If the printer is attached via TCP/IP, this message could be caused by TCP/IP being recycled. This message will appear on the operator console. System Action: The data set being printed at the time of the error is restarted from the most recent checkpoint before the interrupt or possibly from the beginning if no previous checkpoint had been taken. User Response: Examine your output for duplicate pages. System Programmer Response: No response is necessary. Operator Response: To determine an appropriate response, see the specific error conditions described in any accompanying console message. Problem Determination: Items 1, 25, 26, 27. 4. Change the System Programmer Response for abend reason code 0E96 to read as follows. System Programmer Response: This PSF abend reason code results from a possible logic error in the microcode of the printer. Contact your hardware service provider for assistance regarding this error code. -----------CHANGES FOR OW41510---------------------------------- 00860000 1. pg 249 update the inserts for message APS933I for ATTACH to read "ATTACH=psf|dpf|psfdirect|wpm" Update the explanation for ATTACH to also list Workstation Print Manager (WPM). -----------CHANGES FOR OW43469---------------------------------- 1. On page 4 under "attachment" add the following under (SNA). (tcpname)--For a TCP/IP attached printer where "tcpname" is the name of the TCP/IP startup procedure. -----------CHANGES FOR OW44001---------------------------------- 00860000 1. Add message APS6504I. APS6504I THE MESSAGE LENGTH IN THE TCP/IP PREFIX IS GREATER THAN THE MAXIMUM LENGTH ALLOWED. Explanation: The message length in the TCP/IP prefix is greater than the maximum message length allowed. System Action: If in the process of bringing up the session, PSF will attempt to restart the session. If already in session, PSF will bring down the session and attempt to restart the session. User Response: No response is necessary. System Programmer Response: This indicates a possible logic error in the microcode of the printer or another problem with the printer. Consult your hardware service provider or the person responsible for the printer for assistance. Operator Response: This indicates a possible logic error in the microcode of the printer or another problem with the printer. Consult your hardware service provider or the person responsible for the printer for assistance. Problem Determination: Items 1, 18. -----------CHANGES FOR OW44399---------------------------------- 00860000 00870000 Add following messages: 1. APS361I THE INPUT BIN WITH COMPONENT ID component ID, MEDIA NAME media name, BIN NUMBER bin number IS NOT SUPPORTED OR NOT ENABLED ON THE PRINTER. MEDIA FIDELITY REQUESTED THE JOB TO BE TERMINATED WITH NO ALTERNATE BIN SUBSTITUTION. Explanation: The Medium Modification Control (MMC) structured field specified a media selection that does not exist on the selected printer or is not enabled. A value of *** for any of the three values means that piece of information was not provided by the MMC structured field. The input bin is selected by a media-source selector keyword with or without media-type local ID keywords in the MMC structured field. The media-type local ID keywords specify the ID of a Map Media Type (MMT) structured field that contains an Object Identifier (OID) with or without a Media Name. The MMC and MMT structured fields are in the form definition. System Action: Processing of the current data set is ended. User Response: Submit the print request to a printer that supports the specified media selection. If you want to use the original printer, and you created the structured fields for the form definition, specify a supported bin in the MMC structured field. For more information about the MMC structured field, refer to Mixed Object Document Content Architecture Reference. If the structured field contains the component ID, media name, or number of a supported bin, the error may be a PSF logic error. If you used a program to create the structured fields for the form definition, ensure that the input to that program specified a supported bin. If it did, consult your system programmer. System Programmer Response: If an IBM licensed program was used to create the structured fields for the form definition with the error, verify that the input to that program was valid. If the input was valid, refer to Print Services Facility/MVS: Diagnosis Guide and Reference before contacting the IBM Support center for assistance in determining the source of the problem. Operator Response: If this message displays on the operator's console, it indicates that the resource containing the error is defined for a separator page, for the message data set, or as the default resource for user print data sets in the PSF startup procedure. Inform your system programmer. Problem Determination: Items 1, 2, 13, 17, 19 2. APS865I THE ACTUAL MEDIA LOADED DOES NOT MATCH THE FORM THAT WAS SELECTED AT THE PRINTER CONSOLE. EXPLANATION: The media currently loaded in the printer does not match the form that was selected at the printer console. The printer detected and reported an asynchronous intervention-required error with an action code of X'0A' (sense byte 2). Bytes 0,1 and 19 of the error are 4035..00. For more information about this error, refer to the printer publications for the printer that reported the error. SYSTEM ACTION: PSF retransmits pages to the printer, starting from the Jam Recovery Printer Counter plus one. PSF may print this message on a separate sheet in the data set to mark the position at which the recovery from this error was started. If repositioning is not supported in the current environment, the data set is ended. USER RESPONSE: The printed output may be acceptable. If the error condition persists, consult your system programmer. SYSTEM PROGRAMMER RESPONSE: If the error condition persists, follow the procedures described in Print Services Facility/MVS: Diagnosis Guide and Reference before contacting the IBM Support Center. OPERATOR RESPONSE: Clear the paper up to the Jam Recovery Printer Counter. Perform the following tasks in order to continue printing: o Verify that the correct form for the job is selected at the printer console. If the correct form for the job is not selected, change it to the correct one. o Load the paper that matches the selected form at the printer console. For a continuous forms printer be sure to NPRO the correct paper up to the Jam Recovery Printer Counter. o If the correct paper for the job is not available, do one of these: - Cancel the job at the printer console. The job will need to be resubmitted when the correct paper is available. - Disable the verifier and continue printing with the paper that is available. PSF assumes that pages between the Jam Recovery Printer Counter and the Stacked Printer Counter are not damaged and do not need to be reprinted. If any pages between these two printer counters do need to be reprinted, use the Job Entry Subsystem (JES) BACKSPACE command. PROBLEM DETERMINATION: Items 1, 8, 18.