IBM pSeries Servers
Microcode Update for Ultrastar SSD1600M

400/800 GB
SAS Solid State Drive
Microcode Level B364

 

DATE: July 28, 2017

Table of Contents

1.       General Information

1.2     Disk Drives Affected

1.2 Microcode Change History

2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System

2.1 Installation Time

2.2 Determine Drive Model, FRU&PN and Current Microcode Level

2.3.1 Internet AIX self extracting file (.bin)

2.3.2 Internet RPM package

2.3.3 CD-ROM

2.4 Microcode Download Procedure

3.   Linux Operating System

3.1 ReadHat (RHEL) and SLES

3.2 Ubuntu

===============================================================

1.  General Information

The Microcode files provided in this package are for SAS disk drives used in IBM system P Servers

with AIX or Linux operating systems

1.2    Disk Drives Affected 

Below is the list of microcode files in this package:

NOTE: To insure the integrity of microcode files, please make sure the checksum value is correct after extraction

 

 

Size

Disk Drive Model

FRU#

P/N (VPD)

Microcode File Name

Check

sum

800GB

HUSMM1680ASS201

00E8702

00LY185

HUSMM16[A1] [A2] .A1700D4F.42333634

35145

00E8709

00LY164

00E8671

00LY168

00E8713

00E8699

00LY162

00E8694

00LY199

00LY197

400GB

HUSMM1640ASS201

00E8672

00LY184

00E8673

00LY163

00E8670

00LY167

00E8710

00E8696

00LY161

00E8693

00LY195

00LY193

 

1.2 Microcode Change History

Release date

Code level

Severity/

Impact

Change Description

July 2017

B364

Availability/

ATT

Fixed Qerr bit change mask violation

July 22016

B22F

 

Fixed the following FW bug: Internal timing condition of a host delayed write would cause a drive to trigger a self-initiated reset condition.

May 2016

B22E

 

Added a new PN, no functional change to FW

June 2015

B22C

 

Fixes intermittent bus issues that cause the drive not to be accessible by the system when installed in the 5887 drawer.  IBM recommends that all customers with the affected drives in the 5887 drawer apply this latest level of code. 

May 2015

B22A

 

Fix for possible undetected data corruption during a series of two or more unaligned sequential read or writes.

Enhancement to signal integrity settings for IBM power series 5887 drawer.

Nov 2014

B222

 

Initial Release

 

 

===============================================================

2.  AIX and VIOS(PowerVM Virtual I/O Server) Operating System

Note: For VIOS systems, microcode of shared physical I/O resources can only be updated from VIOS partition.

To update disk drive microcode, from VIOS partition, enter the following command:     

oem_setup_env   

Then follow the instruction in section 2.3 to transfer/extract the microcode file, and section 2.4.1 to update the disk drive code.

2.1 Installation Time

Approximately 20 minutes if using Diagnostics CD; Approximately 5 minutes/drive using AIX concurrent diagnostics.
 

2.2 Determine Drive Model, FRU&PN and Current Microcode Level
To see the drive type and current microcode level, Execute the following command:
lscfg -vl hdisk* |pg      ; For drives NOT configured for RAID

lscfg –vl pdisk* |pg     ; For drives configured for RAID

 

 Vital Product Data (VPD)

hdisk9           U5887.001.G42N030-P1-D16  SAS 4K Solid State Drive (800000 MB)

 

        Manufacturer................IBM

        Machine Type and Model......HUSMM1680ASS201

        FRU Number..................00LY162

        ROS Level and ID............42333634

        Serial Number...............0RV1LV0A

        EC Level....................L36403

        Part Number.................00E8694

        Device Specific.(Z0)........000006329F003002

        Device Specific.(Z1)........SPIPB364

        Device Specific.(Z2)........0068

        Device Specific.(Z3)........14129

        Device Specific.(Z4)........

        Device Specific.(Z5)........22

        Device Specific.(Z6)........L36403

        Hardware Location Code......U5887.001.G42N030-P1-D16

 

If the data returned in the “Part Number”, “FRU Number”, and “Machine Type and Model”  fields match the one listed in section 1.1 AND the "ROS Level and ID...." field of that data is below " 42333634", this microcode applies.

Note: Drive microcode level in “ROS Level and ID …” field is displayed in Hex value of ASCII characters in VPD data. Each alpha-numeric ASCII character converts to a 2-digit hex number. For example in VPD displayed above, 42 Hex= ASCII character "B"; 33 Hex= ASCII character "3"; 36 Hex=ASCII character "6"; 34 Hex=ASCII character "4",  microcode level is "B364 ". Also note that the microcode level "B364 " is displayed in “Z1” field.

===============================================================

2.3 Transferring and Unpacking the Microcode Update Package

2.3.1 Internet AIX self extracting file (.bin)

a) Make a directory on an AIX system to receive the AIX format file.
    Enter:      mkdir /tmp/fwupdate
b) Transfer the AIX format file to /tmp/fwupdate directory (using "Save as ...").
    You'll see the filename is SSD1600M.bin
c) Unpack the file by executing the instructions below.
  Enter the commands:
  cd /tmp/fwupdate
  chmod +x SSD1600M.bin
  ./SSD1600M.bin
[Don't overlook the periods (.) in the above command.]

The directory SSD1600M with microcode files listed in section 1.1 will be added to /tmp/fwupdate.
 

d-Enter the following command to copy the microcode files to " /etc/microcode " directory :
   cp /tmp/fwupdate/ SSD1600M /HUSL*  /etc/microcode

e- If transferring files to a different system using floppy diskettes, use the following procedure to copy files to diskette
   Note: Don't overlook the complete path of microcode files, AIX Diag microcode download

  will not work if files are not copied with complete path onto the diskette

Enter the following command to copy microcode file(s) onto a floppy diskette
ls /etc/microcode/ microcodefilename  | backup -ivf /dev/rfd0
where microcodefilename is  microcode file that is needed, for example:
ls /etc/microcode/ HU*
| backup -ivf /dev/rfd0

2.3.2 Internet RPM package

Note: The instructions that follow are specific AIX commands. AIX commands are CASE (lower and upper) SENSITIVE,

and must be entered exactly as shown, including filenames.

a) Make a directory on an AIX system to receive the RPM format file.
    Enter:      mkdir /tmp/microcode

b) Transfer the RPM format file to the /tmp/microcode directory.
    You'll see the filename is SSD1600M-B364-AIX.rpm

c) Unpack the file by executing the instructions below:
    Enter the commands:
        rpm -ihv --ignoreos  --force SSD1600M-B364-AIX.rpm   ;(please note, there are two dashes)

The file size and checksum will be verified.

The microcode files will be added to /etc/microcode/
 

2.3.3 CD-ROM

Copy microcode updates from the CD-ROM to standard locations on your local disk:

1. RPM packaged microcode files will be copied to "/tmp/microcode/RPM"
2. Microcode files will be copied to /usr/lib/microcode

Notes:
 - "/etc/microcode"  is a symbolic link to   "/usr/lib/microcode".
 - If permission does not allow the copy to the above stated directory
   or file then the user will be prompted for a new location.
========================================================

2.4 Microcode Download Procedure

Warning: Do not power off the system or the drive during microcode download as this may permanently damage the disk drive

NOTE: Please save current and older versions of the microcode update files in case you need to restore your system.

Caution: The microcode download process is nondestructive to the hard disks; however, as a precaution, ensure that a backup operation has been performed on the affected systems PRIOR to the microcode installation.

Can microcode be installed Concurrently?  YES
Is system reboot needed to activate the microcode: Yes if stand alone diagnostics CD is used, NO if concurrent diagnostics is used.

Installation Time: Approximately 20 minutes/drive if stand alone diagnostics is used(using Diagnostics CD); Approximately 5 minutes/drive if concurrent diagnostics is used.

2.4.1.2.1 Concurrent Download

1. Type diag at the prompt.
2. Select the "Task Selection" from diagnostics menu.
3. Select "Microcode Download" from "Task Selection" menu.
4. Select resource that microcode will be applied to(hdisk? For physical disk, pdisk for RAID configured disks) and press ENTER, then press "F7" to commit..
5- A small screen displays the message " *** NOTICE***  The microcode installation occurs while the attached drives are available for use..... "
    Press enter to continue
6.  Select the source for microcode, use arrow key to go up/down, Enter to continue.
                      /etc/microcode
                      diskette

   - Use /etc/microcode if "restore" command is used to copy files from diskette onto the disk
   - Use diskette if using diskette as the source for download

NOTE: A prompt will ask you to insert the microcode diskette in diskette drive(if Diskette is selected above).  Insert the diskette and press ENTER

7- Display shows a list of microcodes available for the selected drive, highlight option "M  ST9xx...", the latest microcode for the drive and press ENTER. A message may warn you that current level of microcode is not available on the media, press ENTER to continue.

8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic(and reboot if needed).

2.4.1.2.2 Standalone (Service Mode) Download

This procedure is used for all drives including rootvg or paging space drives
1. Properly shutdown the system.
2. Boot up the system in standalone diagnostics mode with the CDROM diagnostics(Use diagnostics level 4.21 or above;  It is recommended to use the same level
    of  Diagnostic CD as the AIX ).
3. Select the "Task Selection" from diagnostics menu.
4. Select "Microcode Download" from "Task Selection" menu.
5. Select resource that microcode will be applied to(hdisk?) and PRESS ENTER.
6. Press "F7" to commit.
      (The current microcode level of the resource you selected earlier will be displayed at the top of the screen)
7. Make the following selections on the next screen:
    Select Input Device --------------------------------------- [ diskette]
    Microcode level to download -----------------------------[ latest]
    Download latest level even if -----------------------------[ yes]
    current is missing

NOTE: A prompt will ask you to insert the microcode diskette into the floppy drive.  Insert the diskette which accompanies these instructions. If this level is already installed in the drive you've selected a message will let you know. A message also may come up to let you know that the Diskette(or Disk) does not have the previous level microcode file. This is true and is not required to complete the download.
PRESS "F7" to commit
8. You will receive a msg. "Current Microcode is...." and "Download has completed successfully"
       (this may take a few minutes)
9. Return to the Tasks Selection menu and repeat this procedure for each hard disk that requires this microcode.
10. Exit diagnostic and reboot system in normal mode.

                             

======================================================

3.   Linux Operating System

 

3.1 ReadHat (RHEL) and SLES

 

Microcode can be updated using the iprconfig utility. The iprconfig utility

allows for multiple levels of adapter and device microcode to exist on the

system at the same time. After the device to update microcode is

selected, all available microcode levels are presented to choose to download.

 

1.  If using SLES 9 base, install the package by typing:

         rpm -ivh --ignoreos SSD1600M-B364-LINUX.rpm

2. Update the microcode by typing:

                                 iprconfig

    Press Enter.

3. Select Download microcode and press Enter.

4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected.

5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter.

6. Press Enter again to confirm the download (display shows “Microcode Download in Progress” with elapsed time)

7. If multiple devices were selected, repeat from Step 5 for the next device.

 

To check the microcode level:

 

1. Start iprconfig utility,

2. Select "Display hardware status" option.

3. Select disk to query by typing a 1 next to it and pressing "Enter"

4. Look at the "Firmware Version" field

 

 

--------------------------------------------------------------------------

3.2 Ubuntu

 

Microcode can be updated using the iprconfig utility. The iprconfig utility

allows for multiple levels of adapter and device microcode to exist on the

system at the same time. After the device to update microcode is

selected, all available microcode levels are presented to choose to download.

 

1.  tar -C-xzvf SSD1600M-B364-LINUX.tgz

2. Update the microcode by typing:

                                 iprconfig

    Press Enter.

3. Select Download microcode and press Enter.

4. Select the device you wish to update by typing a 1 then pressing Enter. Multiple devices may be selected.

5. Select the microcode image to be downloaded to the device by typing a 1 then pressing Enter.

6. Press Enter again to confirm the download (display shows “Microcode Download in Progress” with elapsed time)

7. If multiple devices were selected, repeat from Step 5 for the next device.

 

To check the microcode level:

1. Start iprconfig utility,

2. Select "Display hardware status" option.

3. Select disk to query by typing a 1 next to it and pressing "Enter"

4. Look at the "Firmware Version" field


 [A1]

 [A2]