FixPack Notes for
Version  2.2.2 of the WBI Adapter for MQ

(for CrossWorlds Infrastructure versions 4.x and WBIA versions 2.x


The patch notes contain the following sections:

CONNECTOR REVISIONS

UPGRADE INSTRUCTIONS

USAGE NOTES

 

ADAPTER REVISIONS

This patch contains fixes for the following CRs based on customer-reported cases.

Available as of Version

CR Number/APAR #

Description

2.2.2

17738,21496/JR17908

CR 17738: The purpose of this enhancement is to provided customers with a way to configure the frequency that the ReplyTo Queue is checked for incoming messages. The values for the configurable property (ReplyToQueuePollFrequency) is in milliseconds.

CR21496: Fixed the support for the feature which makes the ‘InProgressQueue’ configuration property of the adapter optional.

2.2.1

18271

Corrected support for processing binary data messages in the polling cycle

 

 


 

UPGRADE INSTRUCTIONS

To perform an upgrade to this version of the connector:

  1. Apply the changes prescribed in each table below, beginning with the entries at the bottom of each table and working up to the most recent patch.

Add, replace, or remove the following files and directories as indicated:

For Adapter Version

Platform [WIN; UNIX]

Add / Replace / Remove

File (Starting from %CROSSWORLDS%/$CROSSWORLDS)

2.2.2

WIN;UNIX

Replace

/connectors/MQSeries/CWMQSeries.jar, /connectors/MQSeries/CWJMSCommon.jar

2.2.1

WIN;UNIX

Replace

CWMQSeries.jar

2.2.1

WIN;UNIX

Replace

CWJMSCommon.jar

Add or remove the following connector properties using CSM:

For Connector Version

Platform

Add / Remove

Property (Case-Sensitive)

2.2.2

WIN:UNIX

Add

ReplyToQueuePollFrequency

2.2.1

WIN;UNIX

none

 

 


USAGE NOTES

CR18271

For processing binary data messages see MQSeries connector guide. (Refer to section on static and dynamic meta objects and the function of the DataEncoding property in the listed table).

 

CR17738

 

To use the feature in this update add a connector application config property called "ReplyToQueuePollFrequency" which takes as it's value a number in milliseconds representing the frequency which messages will be checked for on the ReplyTo queue.

 

CR21496

To use the feature fixed in this update, remove the connector configuration property ‘InProgressQueue’ or do not set a value for the property.

 

 